Desa CHL3924PR user manual

User manual for the device Desa CHL3924PR

Device: Desa CHL3924PR
Category: Water Heater
Manufacturer: Desa
Size: 1.62 MB
Added : 7/27/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa CHL3924PR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa CHL3924PR.

For your convenience

If looking through the Desa CHL3924PR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa CHL3924PR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa CHL3924PR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa CHL3924PR User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa CHL3924PR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa CHL3924PR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

L
I
P
F
F
O
H I
L O
UNVENTED (VENT-FREE) GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
18”, 24” AND 30” REMOTE READY
(Yellow Flame Model Shown)
CCL3018NR, CCL3018PR, CCL3018NRA, CCL3018PRA
CCL3924NR, CCL3924PR, CCL3924NRA, CCL3924PRA
CHL3924NR, CHL3924PR,
CCL3930NR, CCL3930PR, CCL3930NRA, CCL3930PRA
Also Design-Certified As Vented Decorative Appliances When
Not Used With Hand-Held Thermostat Remote
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosio

Summary of the content on the page No. 2

WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fire- place or in a listed ventless firebox enclosure. It is de- sign-certified for these ins

Summary of the content on the page No. 3

SAFETY INFORMATION WARNING: Do not allow fans to blow directly into the fireplace. WARNING: This product con- tains and/or generates chemicals Avoid any drafts that alter burner known to the state of California flame patterns. Ceiling fans can to cause cancer or birth defects create drafts that alter burner or other reproductive harm. flame patterns. Altered burner patterns can cause sooting. IMPORTANT: Read this owner’s Due to high temperatures, the manual carefully and completely befor

Summary of the content on the page No. 4

13. Do not run heater SAFETY INFORMATION • where flammable liquids or vapors are used Continued or stored 4. If you smell gas • under dusty conditions • shut off gas supply 14. Do not use this heater to cook food or burn • do not try to light any appliance paper or other objects. • do not touch any electrical switch; do not use 15. Do not use heater if any part has been exposed any phone in your building to or under water. Immediately call a qualified • immediately call your gas supplier from

Summary of the content on the page No. 5

SAFETY PILOT PRODUCT This heater has a pilot with an Oxygen Deple- IDENTIFICATION tion Sensing (ODS) safety shutoff system. The Log Set ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system re- quires no matches, batteries or other sources to Optional light heater. Remote Control REMOTE CONTROL ACCESSORIES Piezo Ignitor There are two optional remo

Summary of the content on the page No. 6

Confined Space and Unconfined Space AIR FOR COMBUSTION The National Fuel Gas Code, ANSI Z223.1/NFPA AND VENTILATION 54 defines a confined space as a space whose vol- Continued ume is less than 50 cubic feet per 1,000 Btu per hour 3 PROVIDING ADEQUATE (4.8 m per kw) of the aggregate input rating of all appliances installed in that space and an unconfined VENTILATION space as a space whose volume is not less than 50 The following are excerpts from National Fuel 3 cubic feet per 1,000 Btu per ho

Summary of the content on the page No. 7

VENTILATION AIR AIR FOR COMBUSTION Ventilation Air From Inside Building AND VENTILATION This fresh air would come from an adjoining un- Continued confined space. When ventilating to an adjoining Example: unconfined space, you must provide two perma- 40,000 Gas water heater __________ Btu/Hr nent openings: one within 12" of the ceiling and 39,000 Vent-free fireplace + ________ Btu/Hr one within 12" of the floor on the wall connecting 79,000 Total = ________

Summary of the content on the page No. 8

INSTALLATION WARNING: Seal any fresh NOTICE: This heater is intended air vents or ash clean-out doors for use as supplemental heat. located on floor or wall of fire- Use this heater along with your place. If not, drafting may cause primary heating system. Do not pilot outage or sooting. Use a install this heater as your pri- heat-resistant sealant. Do not mary heat source. If you have a seal chimney flue damper. central heating system, you may run system’s circulating blower WARNING:

Summary of the content on the page No. 9

INSTALLATION Continued Example WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted. * INSTALLATION AND CLEARANCES *Minimum 16 inches from Side Wall (Vent-Free Operation Only) Figure 4 - Minimum Clearance for Combustible to Wall WARNING: Maintain the minimum clearances. If you can, NOTICE: Manual control heaters provide greater clearances from may be used as a vented product. floor, ceiling and adjoining wall. If so, you must always

Summary of the content on the page No. 10

MANTEL CLEARANCES INSTALLATION In addition to meeting noncombustible material Continued clearances, you must also meet required clearances If Using Mantel between fireplace opening and mantel shelf. If You must have noncombustible material(s) above you do not meet the clearances listed below, you the fireplace opening. Noncombustible materials will need a hood. (such as slate, marble, tile, etc.) must be at least Determining Minimum Mantel Clearances 1/2 inch thick. With sheet metal, you mu

Summary of the content on the page No. 11

INSTALLATION Continued NOTICE: If your installation does Hearth not meet the minimum clear- Combustible Material ances shown, you must do one 5" of the following: Min. • operate the logs only with the flue damper open Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring • raise the mantel to an accept- able height INSTALLING DAMPER CLAMP • remove the mantel. ACCESSORY FOR VENTED OPERATION Mantel Shelf 12" Underside Note: When used as a vented heater, appliance of Mantel 10"

Summary of the content on the page No. 12

Installation Items Needed INSTALLATION • hardware package (provided with heater) Continued • approved flexible gas hose (not provided) (if Damper allowed by local codes) Clamp • sealant resistant to propane/LP gas, not provided Damper • electric drill with 3/16” masonry drill bit Note: Install optional remote receiver and hand- Damper held remote kit (see Accessories, page 34) before Clamp installing gas log heater. See installation instruc- tions included with the kit. Damper Damper 1. App

Summary of the content on the page No. 13

For propane/LP units, the installer must supply INSTALLATION an external regulator. The external regulator will Continued reduce incoming gas pressure. You must reduce CONNECTING TO GAS SUPPLY incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- WARNING: This appliance sure, heater regulator damage could occur. Install external regulator with the vent pointing down requires a 1/2" NPT (National as shown in Figure 13. Pointing the vent down

Summary of the content on the page No. 14

CHECKING GAS CONNECTIONS INSTALLATION Continued WARNING: Test all gas piping and connections, internal and WARNING: Use pipe joint external to unit, for leaks after sealant that is resistant to liquid installing or servicing. Correct petroleum (LP) gas. all leaks at once. We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sediment WARNING: Never use an trap where it is within reach for cleaning. Install open flame to check for a leak. in pipi

Summary of the content on the page No. 15

Propane/LP Equipment INSTALLATION Tank Shutoff Valve Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 15). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. Thermostat Gas Valve or 3. Check all joints from propane/LP supply tank Control Valve Location to equipment shutoff valve for

Summary of the content on the page No. 16

INSTALLATION Continued Receiver 4. Install remote receiver unit onto gas log heater base using phillips head screws (see Figure 19). 5. Connect wires as shown in Figure 20. Terminal 9-Volt Battery Wires Battery F ront Clip Screws Figure 21 - Installing Receiver on the Back of the Base Bac k Installing 9-Volt Battery (Not Included) in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. Remote Receiver 2. Attach terminal wires to the battery. Place b

Summary of the content on the page No. 17

A U T O A U T O A U T O O N O N O F F O FF O N O F F Front Log INSTALLATION (#1) Continued INSTALLING LOGS Grate WARNING: Failure to posi- Fingers tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may Grate result in property damage or Base personal injury. Figure 24 - Installing Front Log (#1) CAUTION: After installa- (CCL3930PR/NR Shown) tion and periodically thereafter, check to ensure that no flame Middle Log (#2)

Summary of the content on the page No. 18

A U T O A U T O A U T O A U T O O N 6 O FF O N O FF O N O N 7 O F F O F F INSTALLATION Crossover Continued Log (#4) 5. Locate pegs on the bottom of crossover log (#5). Slide these pegs into the holes located in crossover log (#4) and front log (#1). See Figure 28. For CCL3018PR/NR Only: Locate holes on the bottom of crossover log (#5). Slide the holes over the left pegs on middle log (#2) and front log (#1). See Figure 29. Front Log 6. Locate pegs on the bottom of crossover log (#6).

Summary of the content on the page No. 19

LIGHTING OPERATING HEATER INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: • If fireplace has glass doors, WARNING: If you do not fol- never operate this heater with low these instructions exactly, glass doors closed. If you op- a fire or explosion may result erate heater with doors closed, causing property damage, per- heat buildup inside fireplace sonal injury or loss of life. will cause glass to burst. Make sure there are no obstructions A. This appliance has a pilot which

Summary of the content on the page No. 20

I P F F O H I L OPERATING HEATER CAUTION: Do not try to ad- Continued just heating levels by using the 4. Press in and turn control knob clockwise equipment shutoff valve. to the OFF position (see Figure 32). 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. WARNING: Make sure the If you smell gas, STOP! Follow “B” in the selector switch is in the OFF safety information, page 19. If you donʼt position when you are away from s


Alternative user manuals
# User manual Category Download
1 Desa 15 User manual Water Heater 0
2 Desa 6000 BTU/HR User manual Water Heater 2
3 Desa and CVDR30 User manual Water Heater 0
4 Desa B User manual Water Heater 0
5 Desa A, C, B User manual Water Heater 0
6 Desa CBT30NT, CBT30PT User manual Water Heater 0
7 Desa CBN20T User manual Water Heater 0
8 Desa CCL3018NTA User manual Water Heater 0
9 Desa CCL3018NA User manual Water Heater 0
10 Desa CCL3018PTA User manual Water Heater 0
11 Desa CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB User manual Water Heater 0
12 Desa CCL3924NA User manual Water Heater 0
13 Desa CCL3924NTA User manual Water Heater 0
14 Desa CCL3930NTB User manual Water Heater 0
15 Desa CDR3924NT User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6