SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 user manual

User manual for the device SPX Cooling Technologies TOPGEAR MAG TG MAG86-100

Device: SPX Cooling Technologies TOPGEAR MAG TG MAG86-100
Category: Water Pump
Manufacturer: SPX Cooling Technologies
Size: 7.45 MB
Added : 3/19/2014
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for SPX Cooling Technologies TOPGEAR MAG TG MAG86-100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with SPX Cooling Technologies TOPGEAR MAG TG MAG86-100.

For your convenience

If looking through the SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual SPX Cooling Technologies TOPGEAR MAG TG MAG86-100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to SPX Cooling Technologies TOPGEAR MAG TG MAG86-100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
TopGear MAG
Magnetic Drive Internal Gear pumps
Read and understand this manual prior to operating
or servicing this product.
A.0500.551 – IM-TG MAG/02.00 GB (02/2008)

Summary of the content on the page No. 2

EC-Declaration of conformity (as per EC's Machinery Directive 98/37/EC, Annex IIA) Producer SPX Process Equipment BE NV Evenbroekveld 2-6 BE-9420 Erpe-Mere Belgium We hereby guarantee that TopGear MAG Magnetic Drive Gear Pumps Types: TG MAG15-50 TG MAG23-65 TG MAG58-80 TG MAG86-100 TG MAG185-125 are in conformity with EC's Machinery Directive 98/37/EC, Annex I. Manufacturer Declaration (as per EC's Machinery Directive 98/37/EC, Annex IIB) The product mus

Summary of the content on the page No. 3

Contents 1.0 Introduction ........................................................................................................ 7 1.1 General ..................................................................................................................7 1.2 Reception, handling and storage ....................................................................7 1.2.1 Reception.......................................................................................................... 7 1.2.2 Han

Summary of the content on the page No. 4

3.16 Components of the magnetic drive..............................................................22 3.16.1 Magnetic coupling ........................................................................................22 3.16.2 Rotor bearing assembly ...............................................................................23 3.16.3 Circulation pump ...........................................................................................24 3.16.4 Sealing rings and gaskets ................

Summary of the content on the page No. 5

3.20 Trouble shooting ...............................................................................................41 3.20.1 Instructions for re-using and disposal ......................................................43 3.20.1.1 Re-use .......................................................................................................43 3.20.1.2 Disposal ....................................................................................................43 3.21 Maintenance instructions ....

Summary of the content on the page No. 6

5.0 Sectional drawings and part lists ................................................................62 5.1 TG MAG15-50 to TG MAG185-125 .........................................................62 5.1.1 Hydraulic part .................................................................................................63 5.1.2 Bearing bracket .............................................................................................63 5.1.3 S-jacket options ......................................

Summary of the content on the page No. 7

1.0 Introduction 1.1 General This instruction manual contains necessary information on the TopGear pumps and must be read carefully before installation, service and maintenance. The manual must be kept easily accessible to the operator. Important! The pump must not be used for other purposes than recommended and quoted for without consulting your distributor. Liquids not suitable for the pump can cause damages to the pump unit, with a risk of personal injury. 1.2 Reception, handling and sto

Summary of the content on the page No. 8

1.3 Safety 1.3.1 General Personnel who have a pacemaker should not be allowed to work with the magnetic coupling! The magnetic field is sufficiently strong to affect the operation of a pace- maker. A safe distance is 3 metre! Important! The pump must not be used for other purposes than recommended and quoted for without consult- ing your distributor. A pump must always be installed and used in accordance with existing national and local environ- mental and safety regulations and laws. When ATEX

Summary of the content on the page No. 9

1.3.2 Pump units 1.3.2.1 Pump unit handling Use an overhead crane, forklift or other suitable lifting device. Secure lifting slings around the front If there are lifting rings on both the Warning part of the pump and the back part of pump and the motor the slings may be Never lift the pump unit with only one the motor. Make sure that the load is fastened to these. fastening point. Incorrect lifts can re- balanced before attempting the lift. NB! Always use two lifting slings. sult in persona

Summary of the content on the page No. 10

1.3.2.3 Before commissioning the pump unit Read the pump’s operating and safety manual. Make sure that the installation has been correctly carried out according to the relevant pump’s manual. Check the alignment of the pump and motor shafts. The alignment may have been altered during transport, lifting and mounting of the pump unit. For safe disassembly of the coupling guard see below: Disassembly/assembly of the coupling guard. Warning The pump unit must not be used with other liquids than

Summary of the content on the page No. 11

1.4 Technical conventions Quantity Symbol Unit Dynamic viscosity µ mPa.s = cP (Centipoise) Kinematic viscosity ν = µ kg — ρ = density ρ 3 [ ] dm 2 mm — ν = kinematic viscosity [ ] = cSt (Centistokes) s Note! In this manual only dynamic viscosity is used. Pressure p [bar] ∆p Differential pressure = [bar] p Maximum pressure at discharge flange (design pressure) = [bar] m Note! In this manual, unless otherwise specified - pressure is relative pressure [bar]. Net Positive NPSHa Net Posi

Summary of the content on the page No. 12

2.0 Pump description TopGear MAG pumps are rotary positive displacement pumps with internal gear. They are made of cast iron or stainless steel. TG MAG pumps are assembled from modular elements, which allows a variety of constructions. Different magnet coupling executions, heating/cooling options, several sleeve bearings, gear and shaft materials and mounted safety relief valve. 2.1 Type designation The pump properties are encoded in the following type indication, which is to be found on the

Summary of the content on the page No. 13

TG MAG 58-80 G2 S 0C BG 2 Q S5 S10 V R 1 2 3 4 5 6 7 8 9 10 11 12 13 7. Idler bush and idler materials SG Idler bush in hardened steel with idler in cast iron CG Idler bush in carbon with idler in cast iron BG Idler bush in bronze with idler in cast iron HG Idler bush in ceramic with idler in cast iron SS Idler bush in hardened steel with idler in steel CS Idler bush in carbon with idler in steel BS Idler bush in bronze with idler in steel HS Idler bush in ceramic with idler in steel US

Summary of the content on the page No. 14

3.0 General information and technical data 3.1 Pump standard parts Outer magnetic rotor Intermediate cover Top cover Pump shaft Bearing bracket Inner magnetic rotor Rotor bearing assembly Idler pin cover Separation can Idler pin Rotor shaft Pump casing Pump cover Idler gear 3.2 Operating principle As the rotor and idler gear unmesh, an underpressure is created and the liquid enters the newly created cavities. Liquid is transported in sealed pockets to the discharge side. The walls of the pump

Summary of the content on the page No. 15

3.2.1 Self-priming operation TopGear pumps are self-priming when sufficient liquid is present in the pump to fill up the clearances and the dead spaces between the teeth. (For self-priming operation see also section 3.18.5.2 Piping). 3.2.2 Safety relief valve – Working principle The positive displacement principle requires the installation of a safety relief valve protecting the pump against overpressure. It can be installed on the pump or in the installation. (See 3.19.4 Checklist – Init

Summary of the content on the page No. 16

3.5 Main characteristics The pump size is designated by the displacement volume of 100 revolutions expressed in litres 3 (or dm ) but rounded followed by the nominal port diameter expressed in millimetres. Pump size d B D Vs-100 n.max n.mot Q.th Q.th v.u v.i ∆p p.test 3 -1 -1 3 TG MAG (mm) (mm) (mm) (dm ) (min ) (min ) (l/s) (m /h) (m/s) (m/s) (bar) (bar) 50 40 100 14.5 1500 3.6 13.1 7.9 1.8 16 24 15-50 1450 3.5 12.6 7.6 1.8 65 47 115 22.5 1500 5.6 20.3 9.0 1.7 16 24 23-65 1450 5.4 19.6 8.7

Summary of the content on the page No. 17

The values depend on the position from where one measures and were therefore measured at the front of the pump, at distance of 1 meter from the pump cover and were corrected for background noise and reflections. The values listed are the highest measured values under following operating conditions. • working pressure: up to 10 bar . • pumped medium: water , viscosity = 1 mPa.s • —% n = — % maximum shaft speed max Lpa (dB(A)) TG MAG pump size n (min-1) Ls (dB(A)) max 25% n 50%n 75%n 10

Summary of the content on the page No. 18

3.7.3 Influences The real sound level of the pump unit can for several reasons deviate from the values listed in the tables above. • Noise production decreases when pumping high viscosity liquids due to better lubricating and damping properties. Moreover the resistance torque of the idler is increasing due to higher liquid friction which results in lower vibration amplitude. • Noise production increases when pumping low viscosity liquids combined with low working pressure because the idle

Summary of the content on the page No. 19

3.10.2 Maximum temperature of internals For some material combinations the general temperature performances must be limited. The maximum allowable working temperature of internals depends on the combination of materials used and their thermal expansions and the interference fit to hold the bearing bush fixed. • Some bush bearings have an extra loc king screw . In this case the maximum allowable tempera- ture is based on the most probable interference fit. • In case the bearing bush has no

Summary of the content on the page No. 20

3.11 Mass moment of inertia TG MAG pump size 15-50 23-65 58-80 86-100 185-125 J (10-3 x kgm²) 3.5 6.8 32 54 200 Outer parts Inner parts Inner parts: Idler Rotor shaft Axial rotor bearings Shaft sleeve Inner magnetic rotor Outer parts: Pump shaft Outer magnetic rotor -3 2 Mass moment of inertia J [ 10 x kgm ] TG MAG outer parts per lenght of magnets inner parts per lenght of magnets type 40/60 80 100 120 40/60 80 100 120 15-50 22 26 - - 8 9 - - 23-65 22 26 - - 10 12 - - 58-80 66 80 93 - 46 52 58


Alternative user manuals
# User manual Category Download
1 SPX Cooling Technologies TOPGEAR MAG TG MAG15-50 User manual Water Pump 4
2 SPX Cooling Technologies TOPGEAR MAG TG MAG185-125 User manual Water Pump 1
3 SPX Cooling Technologies TOPGEAR MAG TG MAG23-65 User manual Water Pump 1
4 SPX Cooling Technologies TOPGEAR MAG TG MAG58-80 User manual Water Pump 0
5 Edelbrock 25-4066 User manual Water Pump 0
6 A.O. Smith Century Pool & Spa Motor User manual Water Pump 156
7 Agilent Technologies Quaternary Pump 1100 Series User manual Water Pump 33
8 Aero Mist 50 Series User manual Water Pump 0
9 Amtrol GUARDIAN CP DC2 User manual Water Pump 3
10 Aqua Flo A Series User manual Water Pump 12
11 Annovi Reverberi RKA 1750 rpm N Version User manual Water Pump 60
12 Annovi Reverberi RKA 1750 rpm E Version 1-1/8" User manual Water Pump 22
13 Annovi Reverberi RKV 3400 rpm D Version - 1" User manual Water Pump 34
14 Annovi Reverberi HRM-A User manual Water Pump 17
15 Annovi Reverberi RK 1450 rpm N Version User manual Water Pump 46