Heat & Glo LifeStyle CERONA-42 user manual

User manual for the device Heat & Glo LifeStyle CERONA-42

Device: Heat & Glo LifeStyle CERONA-42
Category: Indoor Fireplace
Manufacturer: Heat & Glo LifeStyle
Size: 4.21 MB
Added : 2/20/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat & Glo LifeStyle CERONA-42. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat & Glo LifeStyle CERONA-42.

For your convenience

If looking through the Heat & Glo LifeStyle CERONA-42 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat & Glo LifeStyle CERONA-42 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat & Glo LifeStyle CERONA-42 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat & Glo LifeStyle CERONA-42 User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat & Glo LifeStyle CERONA-42 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat & Glo LifeStyle CERONA-42. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Model(s):
CERONA-36
CERONA-42
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are hot during
or explosion m

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The

Summary of the content on the page No. 3

Table of Contents 9 Gas Information 1 Listing and Code Approvals A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 C. H

Summary of the content on the page No. 4

Listing and Code Approvals 1 1 A. Appliance Certifi cation C. High Altitude Installations U.L. Listed gas appliances are tested and approved with- MODELS: CERONA-36, CERONA-42 out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. LABORATORY: Underwriters Laboratories, Inc. (UL) When installing this appliance at an elevation above 2000 TYPE: Direct Vent Gas Appliance Heater feet, it may be necessary to decrease the input rating STANDARD: ANSI Z21.88b-2005 • C

Summary of the content on the page No. 5

Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed F. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall

Summary of the content on the page No. 6

Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the out- Inspect appliance and components for damage. side. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. CAUTION • Do NOT install incomplete components

Summary of the content on the page No. 7

Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: • Illustrations/diagrams are not drawn to scale. • Around air openings • Actual installation may vary due to individual design preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to Note: For actual

Summary of the content on the page No. 8

insulation. If the appliance is being installed on a cement B. Constructing the Appliance Chase slab, a layer of plywood may be placed underneath to pre- A chase is a vertical boxlike structure built to enclose the vent conducting cold up into the room. gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- C. Clearances quired to be, installed inside a chase. Construction of the chase may vary with the type of build- WARNING ing. Th

Summary of the content on the page No. 9

D. Mantel Projections CEILING COMBUSTIBLE SHEATHING CLEARANCE 1 in. A TO CEILING CEILING TYPICAL COMBUSTIBLE FACING MATERIAL 12" 11" 10" 9" FIREPLACE HEADER 8" E 7" B MINIMUM 6" MINIMUM 5" FROM TOP OF ARCH 4" OPENING TO CEILING 3" A 2" 1" B NON-COMBUSTIBLE NON-COMBUSTIBLE FACING MATERIAL C D FACING MATERIAL MINIMUM IN SHADED AREAS FROM TOP OF ARCH OPENING TO FIRST MANTEL PROJECTION FIREPLACE ARCH OPENING TOP OF ARCH OPENING AB C D E in. 32-1/4 16-3/4 16 11 49 1 in. Cerona-36 (25) mm 819 425 406

Summary of the content on the page No. 10

NON-COMBUSTIBLE HEARTH EXTENSION E. Hearth Extension WARNING 8 in. min. Fire Risk. (203 mm) Hearth extension required to protect 1 in. max. (25 mm) combustible fl oors in front of appliance. • An 8 inch minimum hearth extension must be constructed of non-combustible material. MARBLE, GRANITE, TILE OR COMBUSTIBLE OTHER NON-COMBUSTIBLE BOTTOM OF SURFACE HEARTH EXTENSION FIREPLACE Figure 3.7 Fireplace sitting on combustible surface. SURFACE MAY BE COMBUSTIBLE 1 INCH MAX. TO ALLOW FOR DOOR CLEARA

Summary of the content on the page No. 11

Termination Locations 4 4 A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL WARNING LOWEST DISCHARGE OPENING Fire Risk. GAS DIRECT VENT TERMINATION CAP Explosion Risk. Inspect external vent cap regularly. X 12 • Ensure no debris blocks cap. • Combustible materials blocking cap may ROOF PITCH IS X/ 12 ignite. • Restricted air fl ow affects burner operation. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H (

Summary of the content on the page No. 12

M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that

Summary of the content on the page No. 13

B. Continue Adding Vent Components COMBUSTIBLE SURFACE CORRECT INCORRECT DIRECTION UP WARNING Fire Risk. HEAT SHIELD Installation of this appliance may require the use 0 of heat shield 385-920 above the fi rst 90 elbow 90º ELBOW in the venting system. Figure 4.6 To Install the Heat Shield: 1. Determine if the heat shield is required. Do so by measuring • If the combustible materials are not in place at the the vertical distance between the top horizontal surface of

Summary of the content on the page No. 14

Vent Information and Diagrams 5 5 A. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description Vertical First section (closest to appliance) of vertical length V1 Second section of vertical length V2 First section (closest to appliance) of horizontal length H1 8-1/2 in. Second section of horizontal length H2 WARNING Horizontal Fire Hazard. Explosion Risk. Figure 5.1 Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue

Summary of the content on the page No. 15

D. Vent Diagrams WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re. 1. Top Vent - Horizontal Termination V Minimum H Maximum 1 1 Cerona-36 ONLY 1/2 ft 152 mm 2 ft 610 mm One Elbow 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 5 ft 1.5 m

Summary of the content on the page No. 16

1. Top Vent - Horizontal Termination - (continued) V Minimum H Maximum Three Elbows 1 1 Cerona-36 ONLY 1/2 ft 152 mm 3 ft 914 mm 1 ft 305 mm 4 ft 1.2 m 2 ft 610 mm 7 ft 2.1 m 3 ft 914 mm 10 ft 3.0 m 4 ft 1.2 m 13 4.0 m H 2 5 ft 1.5 m 16 4.9 m V 2 6 ft 1.8 m 17 5.2 m 7 ft 2.1 m 22 6.7 m H + H = 22 ft. (6.7 m) Max. 1 2 V + V + H + H = 62 ft. (18.9 m) Max. 1 2 1 2 V H 1 1 Note: Must have Minimal Vertical Vent a minimum verti- Model ft. mm cal vent before Cerona-36 1/2 152 attaching a 90º el

Summary of the content on the page No. 17

2. Top Vent - Horizontal Termination - (continued) V Minimum H Maximum 1 1 Two Elbows Cerona-36 ONLY 1/2 ft 152 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 5 ft 1.5 m 3 ft 914 mm 8 ft 2.4 m 4 ft 1.2 m 11 ft 3.4 m 5 ft 1.5 m 14 ft 4.3 m V 2 6 ft 1.8 m 17 ft 5.2 m 7 ft 2.1 m 20 ft 6.1 m 8 ft 2.4 m 23 ft 7.0 m H = 23 ft. (7.0 m) Maximum 1 V + V + H = 63 ft. (19.2 m) Maximum 1 2 1 V 1 H 1 Note: Must have Minimal Vertical Vent a minimum verti- Model ft. mm cal vent before Cerona-36 1/2 152

Summary of the content on the page No. 18

Vent Clearances and Framing 6 6 A. Pipe Clearances to Combustibles B. Wall Penetration Framing Combustible Wall Penetration WARNING Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.3) whenever a wall is penetrated. Fire Risk. Use same size framing materials as those used in the wall Explosion Risk. construction. The wall shield fi restop maintains minimum Maintain vent clearance to combustibles as clearances and prevents cold air infi ltration. specifi ed.

Summary of the content on the page No. 19

C. Vertical Penetration Framing WARNING Fire Hazard Keep loose materials or blown insulation from touching the ATTIC ABOVE vent pipe. • National building codes recommend using attic shield to keep loose materials/ blown insulation from contacting vent. • Hearth & Home Technologies requires 10 IN. (254 MM) the use of an attic shield. Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/fl oor (see Figure 6.4). • Frame the

Summary of the content on the page No. 20

Appliance Preparation 7 7 A. Removing Non-combustible Facing Mate- CAUTION rial Assembly Handle with care. The non-combustible assembly is located on the back of • Non-combustible material may be damaged if dropped. appliance (see Figure 7.1). • Hold non-combustible pieces in place. • Remove and save two screws from upper brackets (see Figure 7.1). • Remove non-combustible pieces. • Remove and save three screws from lower bracket (see Figure 7.1). • Discard brackets. • Replace screws i


Alternative user manuals
# User manual Category Download
1 Heat & Glo LifeStyle CERONA-42 User manual Door 0
2 Heat & Glo LifeStyle 6000 GDVFL User manual Indoor Fireplace 22
3 Heat & Glo LifeStyle 6000 XLT User manual Indoor Fireplace 5
4 Heat & Glo LifeStyle 6000 XLS User manual Indoor Fireplace 10
5 Heat & Glo LifeStyle 6000 ARCH User manual Indoor Fireplace 0
6 Heat & Glo LifeStyle 6000GCF-IPILP User manual Indoor Fireplace 0
7 Heat & Glo LifeStyle 6000GCF-IPI User manual Indoor Fireplace 1
8 Heat & Glo LifeStyle 6000GLX-IPI-S/-R User manual Indoor Fireplace 3
9 Heat & Glo LifeStyle 6000GLX-IPILP-S/-R User manual Indoor Fireplace 1
10 Heat & Glo LifeStyle 6000CL-IPI-T User manual Indoor Fireplace 0
11 Heat & Glo LifeStyle 6000 DVTFL User manual Indoor Fireplace 13
12 Heat & Glo LifeStyle 6000TR-OAK User manual Indoor Fireplace 2
13 Heat & Glo LifeStyle 6000CMOD-IPI User manual Indoor Fireplace 0
14 Heat & Glo LifeStyle 6000TR-OAK-IPI User manual Indoor Fireplace 1
15 Heat & Glo LifeStyle 6000CL-IPI-S User manual Indoor Fireplace 0
16 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
17 AEG Royal Belmont G20 User manual Indoor Fireplace 3
18 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
19 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
20 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1