Regency Wraps P36-LPG4 user manual

User manual for the device Regency Wraps P36-LPG4

Device: Regency Wraps P36-LPG4
Category: Indoor Fireplace
Manufacturer: Regency Wraps
Size: 3.52 MB
Added : 11/16/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Regency Wraps P36-LPG4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Regency Wraps P36-LPG4.

For your convenience

If looking through the Regency Wraps P36-LPG4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Regency Wraps P36-LPG4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Regency Wraps P36-LPG4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Regency Wraps P36-LPG4 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Regency Wraps P36-LPG4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Regency Wraps P36-LPG4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owners &
Installation
P36 Gas Log Fireplace
Models: P36-NG4
P36-LPG4
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
FOR YOUR SAFETY
Improper installation, adjustment, alteration,
What to do if you smell gas:
service or maintenance can cause injury or
Do not try to light any
property damage. Refer to this manual. For
appliance
assistance or additional information consult
Do not touch any electrical
an authorised installer, service agency or
switch: do not use any
LISTI

Summary of the content on the page No. 2

TO THE NEW OWNER: Congratulations! You are the owner of a state-of-the-art Gas Log Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL. The P36 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P36 has been approved by the Australian Gas Association for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please t

Summary of the content on the page No. 3

TABLE OF CONTENTS OPERATING INSTRUCTIONS DATA BADGE Optional Fan ................................................................30 Data Badge ...................................................................4 Operating Instructions .................................................30 Normal Operating Sounds Of Gas Appliances ............31 INSTALLATION Shutdown Procedure ...................................................31 First Fire ...........................................................

Summary of the content on the page No. 4

DATA BADGE ® This is a copy of the label that accompanies The label is located on the front inside base of the DATA BADGE NOTE: Regency units are each P36 Zero Clearance Room Sealed Gas unit, visible when the bottom louvre is open. constantly being improved. Check the label on Fireplace. We have printed a copy of the contents the unit and if there is a difference, the label on here for your review. the unit is the correct one. (Australia Only) ® 4 Regency P36-4 Gas Log Fireplace

Summary of the content on the page No. 5

INSTALLATION IMPORTANT MESSAGE GENERAL SAFETY INSTALLATION SAVE THESE INSTRUCTIONS INFORMATION CHECKLIST The P36-NG or P36-LPG Room Sealed Fireplace 1) The appliance shall be installed in 1) Locate appliance must be installed in accordance with AS5601- accordance with the manufacturer's a) Locate Your Gas Fireplace 2004 and NZS 5261 5261 and these instructions. installation instructions,local gas fi tting b) Clearances Carefully read all the instructions in this manual regulations, municipa

Summary of the content on the page No. 6

INSTALLATION NOTE: The minimum fl oor clearance must LOCATING YOUR MANUFACTURED be maintained from the top surface of the carpeting, tile, etc. GAS FIREPLACE MOBILE HOME ADDITIONAL Minimum Clearance from Top of Unit to: 1) When selecting a location for your stove, Mantel* Minimum 7" (177mm) ensure that the clearances outlined on this REQUIREMENTS Ceiling from top of unit. 32" (1016mm) page are met. 1) Ensure that structural members are not cut Side Wall Clearance 2) Provide adequate

Summary of the content on the page No. 7

INSTALLATION ® Regency P36-4 Gas Log Fireplace 7 COMBUSTIBLE MANTELS Note: A non-combustible mantel may be installed at a lower height if the framing Because of the extreme heat this fi replace emits, the mantel clearances are critical. is made of metal studs covered with a non-combustible board. Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2. Diagram 1 Diagram 2 These drawings are to scale at 1:6 (one inch = 6 inche

Summary of the content on the page No. 8

INSTALLATION 2) Frame in the enclosure for the unit with MANTEL LEG framing material. CLEARANCES Combustible mantel leg clearances as per diagram below: 152m m Side Wall P36 Fireplace Maximum 38mm projection 51m m at 51mm minimum 127m m clearance. Allowable mantel leg projection. Standard Framing Dimensions A B C D FRAMING AND Note: 40-1/2" (1029mm) is the minimum 36-1/4" 36-1/4" 12-3/4" 46"* height for both fl ex termination or FINISHING 921mm 921mm 324mm 1126mm* Simp

Summary of the content on the page No. 9

INSTALLATION 1) Mount Top Facing Support using the 3 Premium Flush Front UNIT ASSEMBLY supplied screws into the three pre-punched Spacer Installation screw holes on the top front of the unit. Use PRIOR TO hole positions A, B, or C depending on your Before the unit is slid into position, install the INSTALLATION facing depth. provided spacers to the side of the fi replace as follows; The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly 1) Align the sc

Summary of the content on the page No. 10

INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum Clearance (mm) a Below eaves, balconies or other projections: - Appliances up to 50 MJ/h input 300 - Appliances over 50 MJ/h input 500 b From

Summary of the content on the page No. 11

INSTALLATION FLUEING ® Regency Direct Vent System (Flex) Horizontal Terminations Only These fl ueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type fl ue system by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in section "Exterior Flue Termination Locations." ® Regency Direct Vent (Flex) System Termination Kit (Part # 946-515) includes

Summary of the content on the page No. 12

INSTALLATION SIMPSON DURA-VENT FLUEING Horizontal or Vertical Terminations The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish. We recommend using the galvanized fi nish for installation with the P36. The minimum components required for a basic Wall thickness is measured from the back If a Vinyl Siding Standoff is required (it

Summary of the content on the page No. 13

INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and ® REGENCY DIRECT VENT SYSTEM (FLEX) (LPG & NG) o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two 45 elbows equal o one 90 elbow). Note: Must use optional fl ue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. Simpson Dura-Vent 4" (102mm) inner diameter 6-5/8" (168mm) outer diameter ® Regency Flex Vent 4" (102mm)

Summary of the content on the page No. 14

INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and ® REGENCY CO AXIAL FLUE SYSTEM (FLEX) (LPG & NG) o o o The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow). o Note: 1) A maximum of two 90 elbows are permitted. o 2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 elbows are used. 3) Minimum distance between elbows is 2 ft. (0.6m). 4) D

Summary of the content on the page No. 15

INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG) The P36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset o o o using two 90 elbows (two 45 elbows equal one 90 elbow) with Simpson Dura-Vent Co Axial Flue GS fl ue systems for LPG and NG, as per diagram 1. The P36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset o o o using two 90 elbow (two 45 e

Summary of the content on the page No. 16

INSTALLATION The P36 is approved for a 37 ft. (11.3m) straight vertical, with Simpson Dura-Vent Co Axial Flue GS fl ue systems for LPG and NG, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura- Vent Co Axial Flue GS fl ue systems for LPG and NG. Maximum two o 45 elbows allowed. • Flue must be supported at offsets • Firestops are required at each fl oor level and whenever passing

Summary of the content on the page No. 17

INSTALLATION b) Horizontal runs of fl ue must be supported HORIZONTAL every three feet. Wall straps are available for this purpose. TERMINATIONS 5) Mark the wall for a 10" x 10" square hole. The Install the fl ue system according to the center of the square hole should line up with manufacturer's instructions included with the centerline of the horizontal pipe. Cut and the components. frame the 10 inch square hole in the exterior wall where the fl ue will be terminated. If the 1) Set

Summary of the content on the page No. 18

INSTALLATION VERTICAL Roof Pitch Minimum Flue Height Feet Meters TERMINATIONS fl at to 7/12 2 0.61 1) Maintain the 1-1/4" over 7/12 to 8/12 2 0.61 clearances (air spaces) over 8/12 to 9/12 2 0.61 to combustibles when over 9/12 to 10/12 2.5 0.76 passing through ceilings, walls, roofs, enclosures, over 10/12 to 11/12 3.25 0.99 attic rafter, or other nearby over 11/12 to 12/12

Summary of the content on the page No. 19

INSTALLATION Conversion Kit #513-968 from NG to LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 8) Remove burner orifi ce with a 1/2" wrench. WARNING! Conversion Kit Contains: Use another wrench to hold on to the elbow Do not over tighten the screw. Qty. Part # Description behind the orifi ce. Discard orifi ce. 1 910-037 LPG Injector Recommended to (Pilot Orifi ce) grip the wrench by the short side. 1 904-390 Burner Orifi ce #52 1 918-590 D

Summary of the content on the page No. 20

INSTALLATION GAS LINE PILOT ADJUSTMENT P36-NG System Data INSTALLATION Periodically check the pilot fl ames. Correct For 0 to 4500 feet altitude fl ame pattern has three strong blue fl ames: Burner Inlet Orifi ce Sizes: #37( 2.65mm) The gas line can be brought through either the 1 fl owing around the thermopile, 1 around right or the left side of the appliance. The gas the thermocouple and 1 fl owing across the Max. Input Rating 33 mj valve is situated on the right hand side


Alternative user manuals
# User manual Category Download
1 Regency Wraps I2400M User manual Indoor Fireplace 0
2 Regency Wraps P36-NG4 User manual Indoor Fireplace 0
3 Regency Wraps U29-NG1 User manual Indoor Fireplace 0
4 Regency Wraps U29-LP1 User manual Indoor Fireplace 1
5 Regency Wraps Z2510L User manual Indoor Fireplace 0
6 Aarrow Fires Becton 7 mk3 User manual Indoor Fireplace 1
7 AEG Royal Belmont G20 User manual Indoor Fireplace 3
8 Austro Flamm Gussofen G3 User manual Indoor Fireplace 1
9 Aarrow Fires Becton Bunny User manual Indoor Fireplace 12
10 Avalon Stoves Victorian Lace DVS Face Black 95200132 User manual Indoor Fireplace 1
11 Avalon Stoves DVL Insert EF II User manual Indoor Fireplace 1
12 Avalon Stoves Newport Bay User manual Indoor Fireplace 6
13 Avalon Stoves Flush Wood Insert User manual Indoor Fireplace 1
14 Avalon Stoves Astoria Bay User manual Indoor Fireplace 2
15 Avalon Stoves ST Fireback 864 User manual Indoor Fireplace 1