Alliance Laundry Systems 70444901R3 user manual

User manual for the device Alliance Laundry Systems 70444901R3

Device: Alliance Laundry Systems 70444901R3
Category: Humidifier
Manufacturer: Alliance Laundry Systems
Size: 1.15 MB
Added : 11/22/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Alliance Laundry Systems 70444901R3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Alliance Laundry Systems 70444901R3.

For your convenience

If looking through the Alliance Laundry Systems 70444901R3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Alliance Laundry Systems 70444901R3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Alliance Laundry Systems 70444901R3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Alliance Laundry Systems 70444901R3 User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Alliance Laundry Systems 70444901R3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Alliance Laundry Systems 70444901R3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Programming
Tumble Dryer
OPL Electronic Control
Refer to Page 3 for Model Identification
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 70444901R3
www.comlaundry.com July 2011

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Introduction......................................................................................... 3 Table of Model Identification ............................................................................. 3 Nameplate Location.............................................................................. 5 Contents Preliminary Information.................................................................... 6 About the Control .................................................................

Summary of the content on the page No. 4

Testing Machine and Electronic Control Functions........................ 27 How to Enter Testing Feature .......................................................... 27 How to Start Tests............................................................................ 27 How to Exit Testing Feature ............................................................ 27 Diagnostic Test Descriptions................................................................ 29 Control Software Version Number Test ..........

Summary of the content on the page No. 5

Introduction Model Identification Gas Steam/Thermal Oil Electric CHD25G2-CA025L DR25G2-BU025L ST025L CHD25S2-CU025S CHD25E2-CT025E CHD25G2-CA025N HA025L ST025N CHD25S2-CT025S CHD25E2-CU025E CHD25G2-CT025L HA025N SU025L DR25S2-BT025S DR25E2-BT025E CHD25G2-CT025N HT025L SU025N DR25S2-BU025S DR25E2-BU025E CHD25G2-CU025L HT025N UA025L HT025S HT025E 25 CHD25G2-CU025N HU025L UA025N HU025S HU025E Pound DR25G2-BA025L HU025N UT025L IPD25S2-IT025S IPD25E2-IT025E DR25G2-BA025N IPD25G2-IT025N UT025N ST025S

Summary of the content on the page No. 6

Introduction (Continued) Gas Steam/Thermal Oil Electric CTT45L HAT45L SAT45L CTT45N HAT45N SAT45N DRST45G2-BAT45L HTT45D STT45D DRST45G2-BAT45N HTT45L STT45L 45 Pound DRST45G2-BTT45D HTT45N STT45N Not Applicable Not Applicable Stacked DRST45G2-BTT45L HUT45L SUT45L DRST45G2-BTT45N HUT45N SUT45N DRST45G2-BUT45L IPD45STG2-ITT45N DRST45G2-BUT45N IPD45STG2-ITT45L CA050L DR55G2-BU050L ST050D CT050S IPD50S2-IT050S CT050E CA050N HA050L ST050L CT050T IPD50S2-IT050T CU050E CT050L HA050N ST050N CU050S ST0

Summary of the content on the page No. 7

Introduction (Continued) Gas Steam/Thermal Oil Electric CA120L DR120G2-BU120N ST120L CT120S HU120T CA120N HA120L ST120N CT120T IPD120S2-IT120S CT120L HA120N SU120L CU120S IPD120S2-IT120T CT120N HT120L SU120N CU120T ST120S CU120L HT120N UA120L DR120S2-BT120T ST120T 120 CU120N HU120L UA120N DR120S2-BU120S SU120S Not Applicable Pound DR120G2-BA120L HU120N UT120L DR120S2-BU120T SU120T DR120G2-BA120N IPD120G2-IT120N UT120N DR120S2-BT120S UT120S DR120G2-BT120L IPD120G2-IT120L UU120L HT120S UT120T DR1

Summary of the content on the page No. 8

Preliminary Information Audit Information About the Control The control collects and stores audit information, This control is an advanced, programmable computer which can be accessed with a PDA or PC. Refer to the that lets the owner control most machine features by following list for some of the available audit pressing a sequence of keypads. information. Refer to PC and PDA Application User The control allows the owner to program custom Instructions. cycles, run diagnostic cycles, and

Summary of the content on the page No. 9

Preliminary Information Restore to Factory Defaults Entering Program Mode When the user resets to factory default, the control 1. Press and hold Stop ( ), then Back ( ), then resets all of the default values. The control also resets Up ( ) to enter the programming options. Machine Cycles #1 through #30. The control will also reset the following to factory-defaults: Default Global Settings Ignition Retries = 3 Temperature Units = Fahrenheit (°F) High (H) Temperature = 190 (°F) Medium (M) Tem

Summary of the content on the page No. 10

Control Identification U Models Operational Keypad The control includes five keypads. These functions are available to the operator and are intended to control and manage operation of the tumbler. Refer to Figure 1, Figure 2, Figure 3, Figure 4 and Table 1. PROGRAM REVERSING ENERGY HEATING SAVER S Models STOP START BACK PROGRAMREVERSING ENERGY HEATING TMB1371R SAVER Figure 3 STOP B, C, and I Models START BACK TMB1345R Figure 1 ECO H Models PROGRAM REVERSING ENERGY HEATING SAVER TMB1375R Fig

Summary of the content on the page No. 11

Control Identification Keypad Description Press to scroll through menu options and edit parameter values. UP ARROW Press to scroll through menu options and edit parameter values. DOWN ARROW Press to go to the list of parameters without saving the value when adjusting the value of a programming parameter. Also, press to go to the previous menu when the control displays a BACK ARROW parameter, return to Idle Mode when the control displays the main menu or clear an error message from the displ

Summary of the content on the page No. 12

Control Identification Rapid Advance Mode Operation Modes If the Rapid Advance Option is enabled, the user can General Modes of Operation advance a running machine cycle by pressing the In each mode of operation, the user may press keypads Start ( ) keypad. In a Time Dry cycle, pressing the or communicate with the control to change the Start ( ) keypad will decrease the remaining time displayed menu. by one minute. Pressing and holding the Start ( ) keypad will decrease the remaining time

Summary of the content on the page No. 13

Control Identification Communication Mode Extended Tumble Mode This mode is entered whenever the control is The Extended Tumble Mode has two portions. The communicating with a PDA. Refer to PC and PDA Anti-Wrinkle Tumble is entered two minutes after the Application User Instructions. cycle has ended if the door is not opened. The cylinder will tumble for 30 seconds every two minutes for up to Cool Down Mode one hour. The control enters the Cool Down Mode after the heat If the door hasn’t be

Summary of the content on the page No. 14

Machine Cycle Definition and Operation There are 30 machine cycles that can be selected and Rotation Sensor Equipped run. Machine cycles can be modified or made Machines “unavailable” by manually editing them in Modify Cycle Menu or by using the PDA to download a On machines equipped with a rotation sensor, the modified machine cycle into the control. Machine control monitors the rotation sensor to verify the cycles cannot be deleted, but can be made cylinder is rotating. The control calcu

Summary of the content on the page No. 15

Entering the Manual Mode For programming, testing, and retrieving information Manual Programming can only be turned on or off from the control, it is often necessary to enter the with an external device. Refer to the appropriate Manual Mode by following the steps below. instruction manual. Diagnostics can be turned on and off using an external device by manual programming. For an overview of entering the Manual Mode, refer to the flowchart on the following page. By default, Manual Programmin

Summary of the content on the page No. 16

Entering the Manual Mode To enter a programming option, press the Start ( / ) Manual Mode: Enter by pressing keypad. To exit, press Stop ( ), then Back (), then the Back () keypad. Up () keypads Press the Up () or Press the Start ( / ) keypad to the Down () keypad “Prog” enter Manual Programming. to scroll through the Manual Refer to Manual Manual Mode options. Programming Programming flowchart. “Avdit” “CyCLE” Press the Start ( / ) Manual Read Total machine cyc

Summary of the content on the page No. 17

Programming Control What Can Be Programmed? How to Program a Cycle This feature allows the owner to program cycle 1. Press the Up ( ) or Down ( ) keypad to scroll parameters and other features by using the keypads. through the option list. The control must have the Manual Programming Mode 2. Press Start ( ) to select an option to program. enabled, which is the factory default. This mode can only be turned OFF and ON by using an external 3. Press the Up ( ) or Down ( ) keypad to change device

Summary of the content on the page No. 18

Programming Control Option Option Default Description Value Range Number Display Value 7“ ” Segment 3 - CXXS31 (Segment 3 Enable/Disable), CXXS32 (Segment 3 Time), CXXS33 (Segment 3 Temperature), CXXS34 (Segment 3 Auto Dry Target Level), CXXS35 (Segment 3 Moisture Dry Target Moisture), CXXS36 (Segment 3 Reversing Enable/ Disable) 8“ ” Segment 4 - CXXS41 (Segment 4 Enable/Disable), CXXS42 (Segment 4 Time), CXXS43 (Segment 4 Temperature), CXXS44 (Segment 4 Auto Dry Target Level

Summary of the content on the page No. 19

Programming Control Option Option Default Description Value Range Number Display Value d“  ” Global High Temperature 190°F/88°C 160°-190°F/71°-88°C (35, T45, 55, 50, 75, 120, 170 Pound Models), 155°-190°F/68°- 88°C (25, 30, T30 Pound Models) 5“ ” Global Audio Signal - - a“  ” End of Cycle 1 0 (oFF), 1 (on) b“  ” End of Cycle Duration (seconds) 5 1-120 c“  ” Keypad Feedback 1 0 (oFF), 1 (on) 6“  ” External Signal - - a“ ” External Signal End of Cycle 1 0 (oFF),

Summary of the content on the page No. 20

Programming Control “Prog” Manual Programming To enter a programming option, press the Start ( / ) keypad. To exit, press Press the Start ( / ) keypad the Back () keypad. “CyCLE-” “CyCXX” “CXXEn” Cycle Programming Cycle to be programmed Cycle XX Enable Disable “on” Enable “oFF” Disable “CXXtyP” Cycle XX Type “tinE” Time Dry Press the Up () “Avto” or the Down () Auto Dry keypad to scroll through the programmable options. “noist” Moisture Dry “CXXnt” Cycle XX Material Type “0” C


Alternative user manuals
# User manual Category Download
1 Edelbrock 15015 User manual Humidifier 0
2 Adam Equipment PAS 16E User manual Humidifier 0
3 Adam Equipment 9618 Revision D User manual Humidifier 11
4 AdobeAir CMC641 User manual Humidifier 9
5 AdobeAir MD524 User manual Humidifier 2
6 AdobeAir CMC431 User manual Humidifier 15
7 AdobeAir CMC442 User manual Humidifier 1
8 AdobeAir L900790A User manual Humidifier 1
9 AdobeAir CM240 User manual Humidifier 2
10 AdobeAir CMC632 User manual Humidifier 1
11 AdobeAir MMPC12A User manual Humidifier 2
12 AdobeAir CMC441 User manual Humidifier 4
13 AdobeAir MS628 User manual Humidifier 3
14 Air-O-Swiss AOS E2241 User manual Humidifier 107
15 AdobeAir UD960 User manual Humidifier 0