Aprilaire 1953 & 1972 user manual

User manual for the device Aprilaire 1953 & 1972

Device: Aprilaire 1953 & 1972
Category: Humidifier
Manufacturer: Aprilaire
Size: 0.2 MB
Added : 11/22/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Aprilaire 1953 & 1972. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Aprilaire 1953 & 1972.

For your convenience

If looking through the Aprilaire 1953 & 1972 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Aprilaire 1953 & 1972 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Aprilaire 1953 & 1972 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Aprilaire 1953 & 1972 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Aprilaire 1953 & 1972 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Aprilaire 1953 & 1972. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Ultraviolet Germicidal Lamps
Model 1952
24” Rooftop Unit
Model 1953
32” Rooftop Unit
Model 1972
Rooftop Unit, Internal Mount
Safety, Installation and Service Manual
Models 1952, 1953 & 1972
READ AND SAVE THIS MANUAL

Summary of the content on the page No. 2

TABLE OF CONTENTS I. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 IV. Annual Lamp Replacement . . . . . . . . . . . . . . . . . . . . .10 II. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 V. Lamp Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 III. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 VI. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

II. APPLICATION Models 1952, 1953, and 1972 Aprilaire Ultraviolet Germicidal Lamps are designed for the treatment of evaporator coils used in rooftop HVAC air handling units or in larger split systems used in the light commercial market. The UV germicidal light emitted from the lamps will kill microorganisms growing on evaporator coils and drain pans and prevent further growth. The units use 120 -277 VAC / 60 Hz / single phase power, and are designed for continuous lamp operation. External Mount

Summary of the content on the page No. 4

INSTALLATION OF EXTERNAL MOUNT ROOFTOP UNITS (MODELS 1952 & 1953) FIGURE 1 – Model 1952/1953 Safety Interlock Switch Ballast Lamp Fuse Lamp Retaining Bracket Unit Base Lamp Base Lamp Socket 90-745 DETERMINE MOUNTING LOCATION Determine a mounting location for the lamp. Use the criteria below to select a proper location: a. The lamps are intended for evaporator coil treatment. See Figure 2 for typical installation. If a single Lamp cannot illuminate the majority of the evaporator coil, two or mor

Summary of the content on the page No. 5

INSTALL THE UNIT BASE 1. Using the Unit Base as a guide, mark the locations for the lamp and mounting holes on the rooftop unit cabinet. 2. Carefully inspect the inside of the rooftop unit and make sure that no damage to any components will occur as a result of drilling the holes. 3. Drill hole for the lamp using a 2 in. hole cutter. At the mounting hole locations, use 3/32 in. drill bit to make pilot holes for mounting screws. 4. Apply weatherproof sealant (not provided) to the side of the Un

Summary of the content on the page No. 6

INSTALL LAMP 1. Remove Lamp from shipping tube. Use ceramic ends of Lamp when handling – do not touch the glass tube of Lamp. Use alcohol to remove any dirt and/or fingerprints from the Lamp. 2. Referring to Figure 4, follow the steps below to install Lamp: a. First, with the Lamp Retaining Bracket removed, slide the Lamp into the large side of the keyhole slot. b. Next, with the shorter side of the ceramic Lamp Base facing the small side of the keyhole slot, slide the Lamp over and into the e

Summary of the content on the page No. 7

CHECK LAMP OPERATION The preferred method for checking lamp operation is to measure the current draw of the lamp using a clamp-on ammeter. To detect the low current of the UV lamp, the ammeter must be capable of measuring 100 mA and above. To prevent accidental exposure to harmful UV germicidal light during this procedure, the location where the amperage measurement is taken must be in a separate compartment from where the UV lamp is installed. To measure the current draw of the lamp: a. First,

Summary of the content on the page No. 8

DETERMINE MOUNTING LOCATION Verify that power to the HVAC equipment is off before continuing. To determine a mounting location for the lamp, use the criteria below to select a proper location: a. The lamps are intended for evaporator coil treatment. See Figure 6 for typical installations. If a single Lamp cannot illuminate the majority of the evaporator coil, two or more units might be required. To the extent possible, the Lamp(s) should be centered on the coil (or section thereof) being illumin

Summary of the content on the page No. 9

MAKE ELECTRICAL CONNECTIONS 1. Verify power to the HVAC equipment is shut off. Determine where the power for the unit will come from. The units can use any voltage from 120 VAC up to 277 VAC (single phase), 60 Hz. The ballast automatically adjusts to whatever voltage is supplied in that range. The units must be wired such that the disconnect switch of the air handler is also the disconnect switch for the UV lamp. Additionally, to prevent accidental exposure to UV germicidal light, it is recommen

Summary of the content on the page No. 10

CHECK LAMP OPERATION The preferred method for checking lamp operation is to measure the current draw of the lamp using a clamp-on ammeter. To detect the low current of the UV lamp, the ammeter must be capable of measuring 100 mA and above. To prevent accidental exposure to harmful UV germicidal light during this procedure, the location where the amperage measurement is taken must be in a separate compartment from where the UV lamp is installed. To measure the current draw of the lamp: a. First,

Summary of the content on the page No. 11

V. LAMP DISPOSAL As with a fluorescent light bulb, the UV lamp contains mercury and must be disposed of properly. Do not throw old lamps into the trash. Many communities have agencies that take in mercury along with other materials – such as old paints, solvents, etc. – that require special disposal. Please contact your municipal or county waste collection agency for proper disposal procedures. If a lamp is broken, do not use a vacuum cleaner to pick up the waste. Instead, sweep up the waste int

Summary of the content on the page No. 12

VIII. LIMITED WARRANTY Your Research Products Corporation Aprilaire Ultraviolet Germicidal Lamp Model 1952, 1953 or 1972 is expressly warranted for three (3) years from the date of installation to be free from defects. However the replaceable lamp is expressly warranted for only one (1) year from the date of installation to be free of defects. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any part of the Ultraviolet


Alternative user manuals
# User manual Category Download
1 Aprilaire 400 User manual Humidifier 2
2 Aprilaire 448 User manual Humidifier 0
3 Aprilaire 1150 User manual Humidifier 1
4 Aprilaire 445 User manual Humidifier 1
5 Aprilaire 500M User manual Humidifier 0
6 Aprilaire 1952 User manual Humidifier 0
7 Aprilaire 224 User manual Humidifier 1
8 Aprilaire 568 User manual Humidifier 0
9 Aprilaire 600 &700 User manual Humidifier 3
10 Aprilaire 760 User manual Humidifier 0
11 Aprilaire 1160 User manual Humidifier 0
12 Aprilaire 1150 User manual Humidifier 0
13 Aprilaire 560 User manual Humidifier 1
14 Aprilaire 700 User manual Humidifier 0
15 Aprilaire 600 & 700 User manual Humidifier 4
16 Edelbrock 15015 User manual Humidifier 0
17 Adam Equipment PAS 16E User manual Humidifier 0
18 Adam Equipment 9618 Revision D User manual Humidifier 11
19 AdobeAir CMC641 User manual Humidifier 9
20 AdobeAir MD524 User manual Humidifier 2