Heat Controller Inc.MGD90-E3A user manual

User manual for the device Heat Controller Inc.MGD90-E3A

Device: Heat Controller Inc.MGD90-E3A
Category: Furnace
Manufacturer: Heat Controller
Size: 1.48 MB
Added : 10/29/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat Controller Inc.MGD90-E3A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat Controller Inc.MGD90-E3A.

For your convenience

If looking through the Heat Controller Inc.MGD90-E3A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat Controller Inc.MGD90-E3A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat Controller Inc.MGD90-E3A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat Controller Inc.MGD90-E3A User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat Controller Inc.MGD90-E3A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat Controller Inc.MGD90-E3A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MGD Series Gas Furnace Installation Instructions
INSTALLATION INSTRUCTIONS
SEALED COMBUSTION

DOWNFLOW MGD SERIES
GAS FURNACE

Summary of the content on the page No. 2

MGD Series Gas Furnace Installation Instructions SPECIFICATIONS 80 AFUE- AUTOMATIC HOT SURFACE IGNITION Model No. MGD60-E3A MGD75-E3A MGD90-E3A MGD60-E5A MGD75-E5A MGD90-E5A Input, BTUH 60,000 75,000 90,000 60,000 75,000 90,000 Output, BTUH 48,000 60,000 72,000 48,000 60,000 72,000 AFUE, % 80.0 81.0 80.0 80.0 81.0 80.0 With A-Coil Cabinet YES YES YES YES YES YES Ignition

Summary of the content on the page No. 3

MGD Series Gas Furnace Installation Instructions SAFETY CONSIDERATIONS INSTALLATION STANDARDS CODE COMPLIANCE The installer shall become familiar with and follow all local codes and regulations which govern the installation of this furnace. Where applicable, local codes may take precedence. • ELECTRIC POWER - tur

Summary of the content on the page No. 4

MGD Series Gas Furnace Installation Instructions RETURN AIR 7. Wiring materials located in the return duct system conform to Article 300-22 (B&C) of the National ALCOVE INSTRUCTION Electric Code, ANSI / NFPA-70. The furnace may be installed free standing or in an 8. Gas piping is not run in or through the return duct alcove with a free flow of air back to the furnace. A system. minimum of 18”

Summary of the content on the page No. 5

MGD Series Gas Furnace Installation Instructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 5

Summary of the content on the page No. 6

MGD Series Gas Furnace Installation Instructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 6

Summary of the content on the page No. 7

MGD Series Gas Furnace Installation Instructions SEALED COMBUSTION ROOF JACK – (REQUIRED) Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 7

Summary of the content on the page No. 8

MGD Series Gas Furnace Installation Instructions CUTTING ROOF JACK OPENING INSTALLATION IN SNOW REGIONS A proper installation of the roof jack requires that When the combustion air inlet to the roof jack is openings in roof and ceiling be on the same vertical blocked with snow, the furnace will not operate centerline as the furnace flue collar. See FIG. 1 properly due to the depleted combustion air

Summary of the content on the page No. 9

MGD Series Gas Furnace Installation Instructions CONNECT POWER SUPPLY 1. Remove the furnace control panel cover. 2. Insert 115 V wiring through a strain relief bushing on the left side of the furnace. 3. Connect the HOT wire to the black pigtail lead; connect the NEUTRAL wire to the WHITE pigtail lead. Secure the connections with suitable wire nuts and wrap with electrical tape. Refer to Wiri

Summary of the content on the page No. 10

MGD Series Gas Furnace Installation Instructions GAS PIPE AND TUBING-MIN SIZES MODEL TYPE LENGTH PIPE TUBING MGD OF SIZE SIZE GAS (FT.) (IN.) (IN. OD) to 20 3/8 5/8 Natural to 60 1/2 - 60 to 70 - 3/4 to 40 3/8 - Propane to 70 - 5/8 to 80 1/2 - to 20 - 5/8 to 50 1/2 - Natural to 60 - 3/4 75 to 80 3/4 - to 30 3/8 - Propane to 60 - 5/8 to 80 1/2 -

Summary of the content on the page No. 11

MGD Series Gas Furnace Installation Instructions WIRING DIAGRAM, MGD Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 11

Summary of the content on the page No. 12

MGD Series Gas Furnace Installation Instructions REPLACEMENT PARTS Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 12

Summary of the content on the page No. 13

MGD Series Gas Furnace Installation Instructions MGD Gas Furnace Parts List ITEM NO. USED ON FURNACE MODEL PART NO. QTY DESCRIPTION 1 All R68DD0010 1 Pressure Switch, -0.20 N.O. 2 All R71CA0006 2 ft. Silicon Tubing 3 All R68CA0005 1 Limit Switch, Manual, Upper-180F 4 All R86GF0050 1 Boost Blower Assembly, w/ Air Orifices 5 All R68GF0001 1 Integrated Control Board, HSI 6 All R68GF0006 1 Gas Valve for HS

Summary of the content on the page No. 14

MGD Series Gas Furnace Installation Instructions Reference: NFPA No. 54, ANSI Z 223.1 National Fuel Gas Code Table shows 4% Input Reduction per 1,000 feet elevation For Canadian High Altitude (2,000-4,500 feet), reduce gas pressure to burner manifold (manifold Ps.) to 3.0” W.C. and 9.0” W.C. for LP (Propane) Gas Heat Controller, Inc. Jackson, MI 49203 MGD I


Alternative user manuals
# User manual Category Download
1 Heat Controller Inc.MGD75-E3A User manual Furnace 1
2 Heat Controller Inc.MGD60-E3A User manual Furnace 0
3 Heat Controller Inc.MGD90-E5A User manual Furnace 0
4 Heat Controller Inc.MGD60-E5A User manual Furnace 1
5 Heat Controller Inc.MGD75-E5A User manual Furnace 0
6 Adams Condensing Oil-Fired User manual Furnace 2
7 AirComm Corporation 10016 User manual Furnace 0
8 AirComm Corporation 7516 User manual Furnace 0
9 AirComm Corporation 50 User manual Furnace 0
10 Air King 9320 User manual Furnace 2
11 Air King 9718 User manual Furnace 5
12 AirComm Corporation 7512 User manual Furnace 1
13 Allied Air Enterprises A80UH User manual Furnace 8
14 Allied Air Enterprises 92G1DF User manual Furnace 0
15 Allied Air Enterprises 95G1DF User manual Furnace 0