Trane 080 user manual

User manual for the device Trane 080

Device: Trane 080
Category: Furnace
Manufacturer: Trane
Size: 0.7 MB
Added : 12/9/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane 080. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane 080.

For your convenience

If looking through the Trane 080 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane 080 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane 080 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane 080 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane 080 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane 080. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TDD-D-1
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)

Summary of the content on the page No. 2

General Features NATURAL GAS MODELS AIR DELIVERY Central heating furnace designs are The variable speed, direct drive blower certified by the International Approval motor, has sufficient airflow for most Services (IAS) for both natural and heating and cooling requirements, will L.P. gas. Limit setting and rating data switch from heating to cooling speeds on were established and approved under demand from room thermostat. The standard rating conditions using blower door safety switch will prevent

Summary of the content on the page No. 3

Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 6 TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V Performance Data 7 Electrical Data 11 Field Wiring 12 Dimensions 15 Pub. No. 22-1682-05-0802 (EN) 3

Summary of the content on the page No. 4

Features and Benefits XV 90 STANDARD EQUIPMENT  HInged blower door  Variable speed indoor blower  Perfect fit door latches  Silicon Nitride Igniter with adaptive  Insulated blower door heat up  Gasketed blower door  Variable speed induced draft blower  Internal filter rack  Direct/Non-Direct vent option  Standard filter sizes  Fused 24 volt control circuit  Two tone color  Manual reset burner safety switches  Complete front service access  Power supply 115/1/60  Left/right gas co

Summary of the content on the page No. 5

Features and Benefits OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ............................................................................

Summary of the content on the page No. 6

General Data TUY-R9V PRODUCT SPECIFICATIONS1 MODEL TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V RATINGS2 1st Stage Input BTUH 39000 52000 65000 78000 3 1st Stage Capacity BTUH (ICS) 37000 49000 62000 74000 2nd Stage Input BTUH 60000 80000 100000 120000 2nd Stage Capacity BTUH (ICS)3 56000 73000 93000 112000 AFUE (ICS) 93.0 92.5 93.0 92.5 Temp. Rise (Min.-Max.) °F. 35 - 65 35 - 65 35 - 65 40 - 70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Dia.-Width (In.) 10 x 8 10 x 8 10 x 10 10 x 10 No. Used 1

Summary of the content on the page No. 7

Performance Data *UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW UNIT SIZE SETTING (TONS) SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW CFM 575 575 575 550 ON ON OFF ON - (350 CFM/TON) WATTS 65 90 125 155 NORMAL CFM 640 640 640 630 1.5 ON ON OFF OFF - (400 CFM/TON) WATTS 70 110 140 175 HIGH CFM 700 700 700 700 ON ON ON OFF - (450 CFM/TON) WATTS 85 125 160 200 LOW CFM 700 700 700 700 OFF

Summary of the content on the page No. 8

Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING (TONS) (See Notes) SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW CFM 750 750 750 720 710 ON ON OFF ON (350 CFM/TON) WATTS 84 122 154 185 221 NORMAL CFM 840 840 840 840 820 2.0 ON ON OFF OFF (400 CFM/TON) WATTS 109 146 181 226 264 HIGH CFM 940 940 940 940 940 ON ON ON OFF (450 CFM/TON) WATTS 136 177 215 27

Summary of the content on the page No. 9

Performance Data TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW CFM 1040 1040 1040 1030 1030 ON ON OFF ON (350 CFM/TON) WATTS 165 220 270 320 375 NORMAL CFM 1210 1210 1230 1230 1230 3.0 ON ON OFF OFF (400 CFM/TON) WATTS 235 285 360 415 475 HIGH CFM 1340 1370 1400 1390 1370 ON ON ON OFF (450 CFM/TON) WATT

Summary of the content on the page No. 10

Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SETTING SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 (TONS) (See Notes) LOW CFM 1210 1210 1220 1230 1230 OFF ON OFF ON (350 CFM/TON) WATTS 220 270 325 400 445 NORMAL CFM 1400 1440 1450 1450 1410 3.5 OFF ON OFF OFF (400 CFM/TON) WATTS 305 390 465 510 560 HIGH CFM 1590 1600 1610 1600 1380 OFF ON ON OFF (450 CFM/TON) W

Summary of the content on the page No. 11

Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TUY060,080,100,120R9V-V LEGEND From Dwg. 21D341111 P03 Pub. No. 22-1682-05-0802 (EN) 11

Summary of the content on the page No. 12

Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341127 Rev. 0 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341126 Rev. 0 12 Pub. No. 22-1682-05-0802 (EN)

Summary of the content on the page No. 13

Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341125 Rev. 1 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341124 Rev. 1 Pub. No. 22-1682-05-0802 (EN) 13

Summary of the content on the page No. 14

Field Wiring FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 From Dwg. 21B341128 Rev. 0 14 Pub. No. 22-1682-05-0802 (EN)

Summary of the content on the page No. 15

Dimensions Pub. No. 22-1682-05-0802 (EN) 15 TUY-R9V-V OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES)

Summary of the content on the page No. 16

File No. PL-UN-FURN-TDD-D-1 3/98 P.I. Supersedes TDD-D-1 8/95 Trane A business of American Standard Companies Since Trane has a policy of continuous product improvement, it reserves the right to change design and www.trane.com specifications without notice.


Alternative user manuals
# User manual Category Download
1 Trane 100 User manual Furnace 1
2 Trane 32-5064-WEB01 User manual Furnace 0
3 Trane TDH2B080A9V3VA User manual Furnace 1
4 Trane TDH2B060A9V3VA User manual Furnace 5
5 Trane GHND-SVX01A-EN User manual Furnace 0
6 Trane 120R9V User manual Furnace 0
7 Trane TDH2B080A9V4VA User manual Furnace 0
8 Trane Air Handlers Gas s User manual Furnace 1
9 Trane TUD2B080A9V3VB User manual Furnace 0
10 Trane TDH2D120A9V5VA User manual Furnace 0
11 Trane TDH2C100A9V4VA User manual Furnace 1
12 Trane TUD2C080A9V4VB User manual Furnace 1
13 Trane TUD2B100A9V3VB User manual Furnace 1
14 Trane TUD2C080B9V4VB User manual Furnace 9
15 Trane TUD2C100B9V5VB User manual Furnace 0
16 Adams Condensing Oil-Fired User manual Furnace 2
17 AirComm Corporation 10016 User manual Furnace 0
18 AirComm Corporation 7516 User manual Furnace 0
19 AirComm Corporation 50 User manual Furnace 0
20 Air King 9320 User manual Furnace 2