Duracell 75 user manual

User manual for the device Duracell 75

Device: Duracell 75
Category: Air Cleaner
Manufacturer: Duracell
Size: 1.23 MB
Added : 12/31/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Duracell 75. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Duracell 75.

For your convenience

If looking through the Duracell 75 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Duracell 75 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Duracell 75 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Duracell 75 User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Duracell 75 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Duracell 75. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CUSTOM PACKAGED
ELECTRONIC
AIR CLEANER
Model 75 Series Units
WITHOUT
Wash System
Accepted For Use
• INSTALLATION
City of New York
Department of Buildings
• OPERATION
MEA 288-01-E and 88-99-E
• SERVICE
For Model Numbers
75- ______-01 & -03
Electrostatic Precipitators for
Commercial & Industrial
Applications
101 McNeill Road • Sanford, NC 27330
(919) 775-2201 • Fax: (919) 774-8771 • (800) 884-0002
www.trioninc.com
MANUAL PART NO. 154024-002 • July 2002

Summary of the content on the page No. 2

TABLE OF CONTENTS SECTION I DESIGN For The System Design Engineer Page 1. General Description ................................................................................................................... 1 2. System Design and Layout........................................................................................................ 1 3. Outdoor Installations ...........................................................................................................

Summary of the content on the page No. 3

If space prohibits, turning vanes, air baffles or other SECTION I DESIGN means may be utilized. Ducting – where attached to the cabinet collars – should be gasketed, caulked or FOR THE SYSTEM DESIGN ENGINEER otherwise made watertight. 1. General Description When there is a danger of rain, snow or debris being The standard major components supplied with each unit drawn into the system with outside air, the make-up air for installation are as follows: intake should be protected with rain louvers,

Summary of the content on the page No. 4

Preferably, straight down from the drain pan supply ****WARNING**** through the floor. The normally recommended drain line Fire Suppression Systems trap, to seal off the cabinet from the drain against the Extreme caution should be exercised when this unit system pressure, should be located in the heated is installed in applications that are collecting interior. If not installed in this manner, heat wrap or volatile or potentially flammable contaminates such other means should be employed to prev

Summary of the content on the page No. 5

sloped toward the cabinet drain pan for an 18-inch one Red for the collector, are factory furnished. length. Each lead is to be run in separate conduit and must be of continuous run (do not splice) between Duct securement to the collar may be completed using the controller and the ionizing-collecting cell the predrilled flange. The seam should be made air and terminal connection in the junction box. watertight by caulking or gasketing. (b). Primary Wiring When a blower is installed downstream fr

Summary of the content on the page No. 6

size, are electrically charged (positively) as they pass are required for the ionizer sections and 6.5 KVDC for through a high voltage ionizer. These charged particles the collector sections of the cells. are then attracted and adhere to a series of parallel collecting plates, which form the negative elements of an electrostatic field. 3. Initial Start-up The ionizer consists of charged stainless steel spiked A. Inspect the inside of the adjoining ductwork and blades spaced between grounded elec

Summary of the content on the page No. 7

The ATS controller and remote PWM box both have 2. Filter-equipped exhaust systems shall not be LED indicating lights to show power to the PWM operated with filters removed. power supplies. Flickering or failed LED’s indicate electrical arcing and/or power failure. 3.The posted instructions for manually operating the fire extinguishing system shall be kept conspicuously 5. Periodic Maintenance A. Fire Suppression System (IF INSTALLED) – posted in the kitchen and reviewed periodically with Every

Summary of the content on the page No. 8

power supply and the ionizing-collecting cell(s) they When a cleaning service is used, a certificate energize. The quantity of power supplies per unit is showing dates of inspection and/or cleaning shall be dependent upon unit size with one or two power maintained on the premises. supplies for each ionizing-collecting cell tier in height. Other than the basic hand tools, it is advantageous to WARNING have a volt meter with a 20 KVDC high voltage probe. Flammable solvents or other flammable These

Summary of the content on the page No. 9

them away from any point of contact and energize the (4) Outage in the power supply. Look for charred or power supply. burned components or a loose wiring connection. Replace power supply or reconnect wiring. a. If either high voltage lead is defective the light will (5) Defective indicating light. Replace light. indicate the trouble. Each lead may then be checked separately by disconnecting them, one at a time, from d. Malfunctions other than short or open circuits. their respective term

Summary of the content on the page No. 10

Troubleshooting Reference Chart PROBLEM/ PROBABLE LOCATION REASON - CORRECTION SYMPTOM CAUSE Ionizing Section of Cell 1. Dirty insulator(s) – Clean 2. Defective insulator(s) – Replace 3. Foreign Object Between Ionizing Bar and Ground electrode - Remove Collecting Section of Cell 1. Dirty insulator(s) - Clean 2. Defective insulator(s) – Replace Short Circuit 3. Foreign Material Bridging Plates - Remove 4. Bent Plates – Straighten or Replace High Voltage Leads 1. Disconnected High Voltage Lead Con

Summary of the content on the page No. 11

Summary of the content on the page No. 12

Summary of the content on the page No. 13

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Summary of the content on the page No. 16

Summary of the content on the page No. 17

Summary of the content on the page No. 18

Summary of the content on the page No. 19

Summary of the content on the page No. 20


Alternative user manuals
# User manual Category Download
1 Sony PK-HS1FL User manual Air Cleaner 1920
2 Sony PK-R1FL User manual Air Cleaner 11
3 Philips AC4053 User manual Air Cleaner 30
4 Philips AC4002/00 User manual Air Cleaner 13
5 Philips AC4055 User manual Air Cleaner 9
6 Philips AC4054 User manual Air Cleaner 13
7 Philips AC4004/00 User manual Air Cleaner 21
8 Philips AC4055/00 User manual Air Cleaner 10
9 Philips AC4062 User manual Air Cleaner 5
10 Philips AC4054/00 User manual Air Cleaner 5
11 Philips AC4063/00 User manual Air Cleaner 1
12 Philips AC4052/00 User manual Air Cleaner 1
13 Philips AC4064 User manual Air Cleaner 6
14 "Dirty" Potato Chips Renesas Semiconductor Devices RJJ01J0007-0600 User manual Air Cleaner 6