National Instruments SCC-TC Series Thermocouple Input Modules user manual

User manual for the device National Instruments SCC-TC Series Thermocouple Input Modules

Device: National Instruments SCC-TC Series Thermocouple Input Modules
Category: Model Vehicle
Manufacturer: National Instruments
Size: 0.29 MB
Added : 5/28/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments SCC-TC Series Thermocouple Input Modules. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments SCC-TC Series Thermocouple Input Modules.

For your convenience

If looking through the National Instruments SCC-TC Series Thermocouple Input Modules user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments SCC-TC Series Thermocouple Input Modules on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments SCC-TC Series Thermocouple Input Modules to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments SCC-TC Series Thermocouple Input Modules User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments SCC-TC Series Thermocouple Input Modules but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments SCC-TC Series Thermocouple Input Modules. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER GUIDE
SCC-TC Series Thermocouple
Input Modules
The SCC-TC Series thermocouple input modules, SCC-TC01 and
SCC-TC02, accept input signals from B-, E-, J-, K-, N-, R-, S-, and T-type
thermocouples. Each module contains thermistor circuitry powered by
2.5 V, to compensate for cold-junction effects and can detect open
thermocouple circuits. Each module has one thermocouple input channel,
which consists of a gain of 100 differential amplifier and a dual-pole 2 Hz
filter.
Note Alternativel

Summary of the content on the page No. 2

bold Bold text denotes items that you must select in the software, such as menu items and dialog box options. Bold text also denotes parameter names. italic Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. monospace Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax e

Summary of the content on the page No. 3

❑ Documentation – One of the following: � SC-2345/2350 User Manual � SCC-68 User Guide – SCC-TC Series Thermocouple Input Modules User Guide – Read Me First: Safety and Radio-Frequency Interference – SCC Quick Start Guide ❑ Tools – 1/8 in. flathead screwdriver – Numbers 1 and 2 Phillips screwdrivers – Wire insulation strippers You can download needed documents from ni.com/manuals. Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the Scaling Volt

Summary of the content on the page No. 4

the inputs of the second-stage SCC. An example of dual-stage conditioning in an SCC-TC0X followed by an SCC-LP01 lowpass filter module. Sockets J9 to J16 also are available for digital input/output (DIO) conditioning or control. Refer to the SC-2345/2350 User Manual for more information on configuring, connecting, and installing SCC modules Note SCC-TC0X dual-stage configuration is only available in NI-DAQmx 7.1 or later. Connecting the Input Signals Note The signal names have changed. Refer

Summary of the content on the page No. 5

E/M Series SCC-TC0X DAQ Device Ref 5 V 10 MΩ Thermocouple Source 10 kΩ + 2-Pole Filter/ TC+ AI (X ) 10 kΩ – Buffer Stage TC- Offset 10 MΩ Calibrator GND (SCC-TC02 only) Ref 5 V AI SENSE 4.75 kΩ AI GND 1% 5 kΩ LM 4040 0.1% 2.5 V + 0.1 μF AI (X+8) 0.1% – + o 5 kΩ 10 μF -t 0.1 μF o at 25 C 16 V 2.5 kΩ Figure 1. SCC-TC0X Signal Connections For more information about how to configure the SCC-TC0X module using NI-DAQmx, refer to the SCC Quick Start Guide. Using the TC0X Scaling Voltage Measu

Summary of the content on the page No. 6

temperature measurements. To make this conversion, complete the following steps: 1. Measure the thermocouple voltage. a. Read the thermocouple channel on the E/M Series DAQ device V [CH(X)]. ESERIES b. Calculate the thermocouple voltage by using the following formula: V ESERIES V = -- --- ---- ---- ---- --- - TC 100 where V is thermocouple voltage. TC V is E/M Series DAQ device voltage. ESERIES This step provides proper scaling for the thermocouple amplifier in the SCC-TC0X. 2. Measure the r

Summary of the content on the page No. 7

Detecting Open Thermocouples The SCC-TC0X contains a 10 MΩ pull-up resistor that connects to +5 V to detect open thermocouples. To determine if you have an open thermocouple, check whether the corresponding E/M Series DAQ device channel is saturated. The pull-up and bias resistors saturate the channel by applying +2.5 V at the input of an open channel. This results in saturation to either the positive or negative rails of the EM Series DAQ device (±10 V). Errors Due to Open-Thermocouple De

Summary of the content on the page No. 8

Cold-Junction Sensor The cold-junction sensor voltage output varies from 1.91 to 0.58 V over a 0 to 55 °C temperature range. Note NI-DAQmx includes thermistor conversion utilities that implement the equations listed below. Refer to your software documentation for more information on these utilities. You can use the following formulas to convert the cold-junction sensor voltage to cold-junction temperature: T() °C = T – 273.15 K where T is the temperature in degrees kelvin. K 1 T = -- ---- ---

Summary of the content on the page No. 9

Calibrating System Offsets To calibrate the offset voltage of the SCC-TC0X in the system using the E/M Series DAQ device, complete the following steps. The E/M Series DAQ device must be powered for 30 minutes before you calibrate the offset voltage. 1. Select the desired channel and gain on the E/M Series DAQ device. 2. Short the inputs on the SCC-TC0X screw terminals or miniplug. 3. While acquiring data on the selected channel, use a screwdriver to adjust the potentiometer protruding throug

Summary of the content on the page No. 10

Specifications These specifications are typical at 25 °C unless otherwise stated. Analog Input Number of input channels.......................1 DIFF Input signals............................................Thermocouples of types B, E, J, K, N, R, S, and T Input signal range ...................................±100 mV Input impedance .....................................10 MΩ powered on, 10 kΩ powered off or overload Bandwidth...............................................2 Hz Amplifier Character

Summary of the content on the page No. 11

1 Measurement Accuracy Thermocouple Temperature Maximum Typical Type Range (°C) Inaccuracy (±°C) Inaccuracy (±°C) B 400 to 600 2.5 0.31 600 to 1,800 2 0.13 E –200 to –100 2 1.76 –100 to 600 1 1 600 to 1,000 1.5 0.6 J –200 to –100 2 1.6 –100 to 500 1 0.9 500 to 1,100 1.5 0.72 K –200 to –100 2.5 1.25 –100 to 600 1.25 0.67 600 to 1,200 2 0.45 N –200 to –100 2.5 2 –100 to 1,300 2 0.7 R –50 to 0 3 1.24 0 to 100 2 0.82 100 to1,600 1.75 0.4 S –50 to 0 3 1.3 0 to 1,400 2 1 1,400 to 1,600 2.5 1 T –200 t

Summary of the content on the page No. 12

Cold-Junction Sensor Cold-junction sensor accuracy................±0.4 °C max from 15 to 35 °C, ±0.75 °C max from 0 to 15 °C and 35 to 55 °C Output .....................................................1.91 V (0 °C) to 0.58 V (55 °C) Note The accuracy specification includes the combined effects of the temperature sensor accuracy and the temperature difference between the temperature sensor and any thermocouple connector. The temperature sensor accuracy includes component tolerances, temperatu

Summary of the content on the page No. 13

1.87 cm (0.74 in.) 7.93 cm (3.12 in.) 3.55 cm (1.4 in.) Figure 3. SCC-TC02 Dimensions Weight TC-01 .............................................. 25 g (0.9 oz) TC-02 .............................................. 22 g (0.8 oz) Screw terminal wire gauge..................... 24 to 12 AWG I/O .......................................................... One 20-pin right angle male connector, 3-pin screw terminal system (SCC-TC02); two-prong mini-connector (SCC-TC01) Screw terminal field-wiri

Summary of the content on the page No. 14

Environmental Operating temperature ............................0 to 50 °C Storage temperature................................–20 to 70 °C Humidity.................................................10 to 90% RH, noncondensing Maximum altitude...................................2,000 m Pollution Degree (indoor use only) ........2 Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: � IEC

Summary of the content on the page No. 15

CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: � 73/23/EEC; Low-Voltage Directive (safety) � 89/336/EEC; Electromagnetic Compatibility Directive (EMC) Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in

Summary of the content on the page No. 16

Table 1 lists the signal connection corresponding to each pin. AI (X) and AI (X+8) are the analog input signal channels of the E/M Series DAQ device. AI GND is the analog input ground signal and is the reference for AI (X) and AI (X+8). A GND is the reference for the ±15 V supplies and REF 5V. AI GND and A GND connect to the SC-2345/2350 at the SCC-PWR connector. Table 1. SCC Module Pin Signal Connections for SCC-TC0X Modules Pin Number Signal 1 AI (X) 2 — 3 — 4 AI (X+8) 5 — 6 DAQ Device A


Alternative user manuals
# User manual Category Download
1 National Instruments SCC-TC Series Thermocouple Input Modules User manual Thermometer 0
2 National Instruments SCC-TC01 User manual Model Vehicle 1
3 National Instruments SCC-TC02 User manual Model Vehicle 1
4 Addonics Technologies CCM35MK2-E User manual Model Vehicle 2
5 Aiphone GT-AC User manual Model Vehicle 4
6 Avanti 308YWT User manual Model Vehicle 325
7 Avanti 309YBT User manual Model Vehicle 65
8 B&B Electronics ESR901 User manual Model Vehicle 2
9 Canon Deluxe Sports Roadster 1 User manual Model Vehicle 1
10 Dell 530 User manual Model Vehicle 0
11 Addonics Technologies CCM35MK1-E User manual Model Vehicle 0
12 Atlas COMMANDER 330 User manual Model Vehicle 4
13 Drive Medical Design 13049SV User manual Model Vehicle 1
14 Eton VECTOR 250R User manual Model Vehicle 85
15 Excalibur electronic NASCAR 9511-3 User manual Model Vehicle 2