ADT Security Services Unimode 9600 user manual

User manual for the device ADT Security Services Unimode 9600

Device: ADT Security Services Unimode 9600
Category: Smoke Alarm
Manufacturer: ADT Security Services
Size: 2.71 MB
Added : 4/21/2013
Number of pages: 148
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADT Security Services Unimode 9600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADT Security Services Unimode 9600.

For your convenience

If looking through the ADT Security Services Unimode 9600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADT Security Services Unimode 9600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADT Security Services Unimode 9600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADT Security Services Unimode 9600 User manual - Online PDF
Advertisement
« Page 1 of 148 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADT Security Services Unimode 9600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADT Security Services Unimode 9600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ADT Security Services, Inc.
One Town Center Road
Boca Raton, FL 33431
Phone: (561) 988-3600
FAX: (561) 988-3675
Unimode 9600
Addressable Fire Alarm Control Panel
Programming, Installation, Maintenance
and Operating Instruction Manual
IMPORTANT! The Signaling Line Circuit Wiring Manual Document #51520 must be referenced in
addition to this manual when installing or servicing the Fire Alarm Control Panel.
Document #51336
C
11/06/01 Revision:
P/N 513

Summary of the content on the page No. 2

While a fire alarm system may lower insurance Fire Alarm System Limitations rates, it is not a substitute for fire insurance! An automatic fire alarm system–typically made up of smoke Heat detectors do not sense particles of combustion and detectors, heat detectors, manual pull stations, audible warn- alarm only when heat on their sensors increases at a prede- ing devices, and a fire alarm control with remote notification termined rate or reaches a predetermined level. Rate-of-rise capability–c

Summary of the content on the page No. 3

Adherence to the following will aid in problem-free Installation Precautions installation with long-term reliability: WARNING - Several different sources of power can be con- Like all solid state electronic devices, this system may nected to the fire alarm control panel. Disconnect all sources operate erratically or can be damaged when subjected to light- of power before servicing. Control unit and associated equip- ning-induced transients. Although no system is completely ment may be damaged

Summary of the content on the page No. 4

Notes 4 Unimode 9600 PN 51336:C 11/06/01

Summary of the content on the page No. 5

Table of Contents SECTION 1: Product Description ........................................................................................................................12 1.1: Inventory .....................................................................................................................................................12 1.2: Features and Options...................................................................................................................................12 1.

Summary of the content on the page No. 6

Table of Contents 3.6.1.2.1 Add Module .........................................................................................................................53 3.6.1.2.2 Delete Module ......................................................................................................................54 3.6.1.2.3 Edit Module Screen for Monitor Module .............................................................................54 3.6.1.2.4 Edit Module Screen for Control Modules ...............

Summary of the content on the page No. 7

Table of Contents 3.7.5: System...............................................................................................................................................101 3.7.6: Zone Setup ........................................................................................................................................103 SECTION 4: Operating Instructions ....................................................................................................................105 4.1: Panel

Summary of the content on the page No. 8

Table of Contents 5.4.1: NFPA Battery Requirements .............................................................................................................130 5.4.2: Selecting and Locating Batteries.......................................................................................................130 APPENDIX A: Software Zones ............................................................................................................................131 A.1: Correlations ................

Summary of the content on the page No. 9

It is imperative that the installer understand the requirements of the Authority Having Jurisdiction (AHJ) and be familiar with the standards set forth by the following regulatory agencies: • Underwriters Laboratories Standards • NFPA 72 National Fire Alarm Code • CAN/ULC - S527M Standard for Control Units for Fire Alarm Systems Before proceeding, the installer should be familiar with the following documents. NFPA Standards NFPA 72 National Fire Alarm Code NFPA 70 National Electrical Code Under

Summary of the content on the page No. 10

10 Unimode 9600 PN 51336:C 11/06/01 Notification Appliance Circuits NAC #1 NAC #2 MS-9600 Basic System Connections Style Y (shown) Style Y or EIA-232 or Style Z Style Z (shown) 13 12 11 10 9 8 7 6 5 4 3 2 1 to printer or 3.0 amps max. 3.0 amps max. 25 24 23 22 21 20 19 18 17 16 15 14 personal computer ELR 4.7K, ½W For EDP-listed equipment or DC Power Outputs (24 VDC) personal computer with FACP 2 Programmable Relays & Supervise with a power supervision relay A77-716B Upload

Summary of the content on the page No. 11

Peripheral Devices and Their Documents: ADT-AFM-16AT & ADT-ACS Series ADT-AFM-32A ADT-ACM-8R Doc. # 51353 Doc. # A15048 Doc. # 51356 ACS (EIA-485) Annunciators ADT-LDM-32 ADT-AFM-16A ADT-UDACT Doc. # 51351 Doc. # A15207 Doc. # 50934 Drill Ack/Step Silence Reset Hold 2 sec. TERM (EIA-485) ADT-LCD-80F Annunciators Doc. # 51589 Unimode 9600 Doc. # 51336 1 SLC Loop Addressable Devices and SLC Wiring Doc. # 51309 Battery Connector ADT-CHG-120 Charger Doc. # 50938 Unimode 9600 PN 51336:C

Summary of the content on the page No. 12

     SECTION 1 Product Description The ADT Unimode 9600 is a compact, cost effective, intelligent addressable FACP (Fire Alarm Control Panel) with an extensive list of powerful features. The combination of newer series devices and legacy 300 Series devices, along with the Unimode 9600 FACP, offer the latest in fire protection technology. The power supply and all electronics are contained on a single circuit board housed in a metal cabinet, providing a complete fire

Summary of the content on the page No. 13

Features and Options Product Description • Annunciators: ✓ ADT-AFM-LED Zone Annunciator Series ✓ ADT-LDM Graphic Annunciator Series ✓ ADT-LCD-80F Liquid Crystal Display point annunciator ✓ ADT-ACM-8R Relay Module • Silence inhibit timer option per NAC • Autosilence timer option per NAC • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability • Selectable strobe synchronization per NAC • Remote Acknowledge, Alarm Silence, Reset and Drill via add

Summary of the content on the page No. 14

Product Description Specifications 1.3 Specifications AC Power - TB1 120 VAC, 60 Hz, 3.2 amps 2 Wire size: minimum 14 AWG (2.00 mm ) with 600 V insulation Battery (Lead Acid Only) - TB2 Maximum Charging Circuit: Normal Flat Charge - 27.6 VDC @ 1.00 amp Maximum Battery Charger Capacity: 25 Amp Hour (Unimode 9600 cabinet holds maximum of two 18 Amp Hour batteries. For greater than 25 Amp Hour up to 120 Amp Hour batteries, use the ADT-CHG-120 Battery Charger and BB-55F Battery Box. Note: Jump

Summary of the content on the page No. 15

Specifications Product Description EIA-485 (ACS) - TB6 ACS annunciator connector, Terminal 1 (+) and Terminal 2 (-) EIA-485 (TERM) - TB7 Terminal Mode annunciator connector, Terminal 5 (In +), 6 (In -), 7 (Out +), 8 (Out -) EIA-232 (ACS) - TB7 PC/Printer Connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground) Auxiliary Trouble Inputs - J16 & J17 Two-pin connectors which can be used to monitor trouble conditions on auxiliary equipment. They can be connected to the trouble bus of a pe

Summary of the content on the page No. 16

Product Description Controls and Indicators 1.4 Controls and Indicators LCD Display The FACP uses an 80-character (4 lines X 20 characters) high viewing angle LCD display. The display includes a SYSTEM ALL NORMAL long life LED backlight that remains 10:00A 010101 illuminated. If AC power is lost and the system is not in alarm, the LED backlight will turn off to conserve batteries. LED Indicators LED indicators are provided to annunciate the following conditions: • AC Power (green) •

Summary of the content on the page No. 17

Circuits Product Description 1.5 Circuits SLC Communication Loop One SLC loop is provided standard on the FACP main circuit board. A second SLC loop is available by plugging the optional SLC module into connector J3 on the main circuit board. SLC loops, configurable for NFPA Style 4, 6 or 7, provide communication to addressable detectors, monitor (initiating device) and control (output device) modules. Refer to the ADT SLC Wiring Manual for information on wiring devices. Reference Manua

Summary of the content on the page No. 18

Product Description Components Cabinet The Unimode 9600 cabinet is red with a navy blue front overlay. The backbox provides space for two batteries (up to 18 Amp Hour). Ample knockouts are provided for system wiring. Also included is a standard dress panel, which mounts to the inside of the cabinet (required on the ULC version). The dress panel must be installed to meet FM requirements. Batteries The Unimode 9600 cabinet provides space for two batteries (up to 18 Amp Hour). Batteries

Summary of the content on the page No. 19

Components Product Description 1.6.2 Intelligent Addressable Modules: Newer Series The newer series of Control Modules and Monitor Modules provide an interface between the control panel and conventional notification and initiating devices. Each module can be set to respond to an address with built-in rotary switches with the ability to select up to 159 addresses (a tab on the address switch must be broken off to use addresses 100-159). A blinking LED on a monitor module indicates communic

Summary of the content on the page No. 20

Product Description Optional Modules 1.6.3 300 Series Intelligent Addressable Devices ADT’s 300 Series Intelligent Addressable Devices are fully compatible with the Unimode 9600 FACP. The devices must be configured for CLIP Mode operation if the control panel is installed in an existing system with 300 Series devices. The address of 300 Series devices cannot be set above 99. Compatible devices include: • SD300 Photoelectric Detector • SD300T Photoelectric Detector with Thermal Sensor • CP


Alternative user manuals
# User manual Category Download
1 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
2 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
3 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
4 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
5 Adobe CS3 User manual Smoke Alarm 1
6 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
7 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
8 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
9 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
10 Aico Ei166RC User manual Smoke Alarm 12
11 Aico Carbon Monoxide Alarm Ei 225EN User manual Smoke Alarm 40
12 Aico Ei161RC User manual Smoke Alarm 5
13 Aico Ei169RF User manual Smoke Alarm 1
14 Aico Ei168RC User manual Smoke Alarm 14
15 Aico Carbon Monoxide Alarms 260 Series User manual Smoke Alarm 0