Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ user manual

User manual for the device Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ

Device: Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ
Category: Gas Heater
Manufacturer: Carrier
Size: 1.42 MB
Added : 8/8/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ.

For your convenience

If looking through the Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48EJ,EK,EW,EY024-048
Single Package Rooftop Units
Electric Cooling/Gas Heating
Installation, Start-Up and
Service Instructions
CONTENTS
Page
1. Improper installation, adjustment, alteration, serv-
SAFETY CONSIDERATIONS...................1
ice,ormaintenancecancausepropertydamage,per-
sonal injury, or loss of life. Refer to the User’s
INSTALLATION .............................1-31
InformationManualprovidedwiththisunitformore
Step 1 — Provide Unit Support ...............1
details.
• ROOF CURB
2. Do

Summary of the content on the page No. 2

ALTERNATEUNITSUPPORT—Whenthepreferredcurb Step 3 — Field Fabricate Ductwork orslabmountcannotbeused,supportunitwithsleeperson 48EJ,EKUNITS—Field-fabricatedductworkshouldbeat- perimeter,usingunitcurbsupportarea.Ifsleeperscannotbe tachedtotheroofcurb.Supplyandreturnductdimensions used, support long sides of unit (refer to Fig. 3-6) with a are shown in Fig. 3 and 4. Air distribution is shown in minimum number of 4-in. x 4-in. pads spaced as follows: Fig. 8. 48EJ,EK,EW,EY024-034unitsrequire3padsonea

Summary of the content on the page No. 3

NOTES: UNIT LEVELING TOLERANCES DIMENSIONS* 1. All roof curb parts are to be 16 ga galvanized steel. (Degrees and Inches) 2. Dimensions are in inches. 3. Topreventstandingwaterinthedrainpanoftheindoor AB sectionandtheheatexchangers,unitcanonlybepitched Deg. in. Deg. in. as shown. 1.0 2.9 .50 .75 *From edge of unit to horizontal. Fig. 1 — Roof Curb (Sizes 024-034) 3

Summary of the content on the page No. 4

NOTES: UNIT LEVELING TOLERANCES DIMENSIONS* 1. All roof curb parts are to be 16 ga galvanized steel. (Degrees and Inches) 2. Dimensions are in inches. 3. Topreventstandingwaterinthedrainpanoftheindoor AB sectionandtheheatexchangers,unitcanonlybepitched Deg. in. Deg. in. as shown. 1.0 2.9 .50 .75 *From edge of unit to horizontal. Fig. 2 — Roof Curb (Sizes 038-048) 4

Summary of the content on the page No. 5

VFD — Variable Frequency Drive NOTES: 1. Weights include economizer (STD). 2. Center of gravity. 3. Do not locate adjacent units with flue dis- chargefacingeconomizerinlet.Minimumclear- ances to be: Adjacent Units: 158-09 Top of Units: No overhang Condenser Coil: 48-09 Economizer Side: 68-09 Gas Heat Side: 48-09 FilterAccess Side: 108-09 (For Removal of Evaporator Coil) 4. For smaller service and operational clear- ances, contact CarrierApplication Engineer- ing department. 5. Bottomductsdesigned

Summary of the content on the page No. 6

VFD — Variable Frequency Drive OPERATING A B CORNER WEIGHT (lb) UNIT WEIGHT NOTES: SIZE 1. Weights include economizer (STD). lb ft-in. ft-in. 1 2 3 4 11 7 2. Center of gravity. 48EJ,EKD038 4442 7- 8 ⁄16 3-10 ⁄8 1021 894 1180 1347 1 3 48EJE038 4602 7-10 ⁄8 3-11 ⁄16 1080 934 1200 1388 3. Donotlocateadjacentunitswithfluedischargefacingecono- mizer inlet. Minimum clearances to be: 5 7 48EJ,EKD044 4668 7- 5 ⁄16 3-10 ⁄8 1033 906 1275 1455 Adjacent Units: 158-09 13 3 48EJE044 4828 7- 6 ⁄16 3-11 ⁄16 1094

Summary of the content on the page No. 7

VFD — Variable Frequency Drive OPERATING A B CORNER WEIGHT (lb) UNIT WEIGHT NOTES: SIZE 1. Weights include economizer (STD). lb ft-in. ft-in. 1 2 3 4 3 3 2. Center of gravity. 48EW,EYD024 4176 6- 0 ⁄8 3-6 ⁄8 879 954 1220 1124 5 11 48EWE024 4256 6- 1 ⁄16 3-6 ⁄16 917 973 1218 1148 3. Donotlocateadjacentunitswithfluedischargefacingeconomizerinlet. Minimum clearances to be: 5 48EW,EYD028 4262 5- 9 ⁄8 3-8 899 899 1232 1232 Adjacent Units: 158-09 1 5 48EWE028 4342 5-10 ⁄8 3-8 ⁄16 929 916 1240 1257 Top

Summary of the content on the page No. 8

VFD — Variable Frequency Drive OPERATING A B CORNER WEIGHT (lb) UNIT WEIGHT NOTES: SIZE 1. Weights include economizer (STD). lb ft-in. ft-in. 1 2 3 4 11 7 2. Center of gravity. 48EW,EYD038 4442 7- 8 ⁄16 3-10 ⁄8 1021 894 1180 1347 1 3 48EWE038 4602 7-10 ⁄8 3-11 ⁄16 1080 934 1200 1388 3. Do not locate adjacent units with flue discharge facing economizer inlet. Minimum clearances to be: 5 7 48EW,EYD044 4668 7- 5 ⁄16 3-10 ⁄8 1033 906 1275 1455 Adjacent Units: 158-09 13 3 48EWE044 4828 7- 6 ⁄16 3-11 ⁄

Summary of the content on the page No. 9

WEIGHT A B C UNIT lb kg in. mm in. mm in. mm 48EJ,EK,EW,EYD024 4176 1894 72.4 1839 42.4 1072 48EJ,EWE024 4256 1930 73.3 1862 42.7 1085 48EJ,EK,EW,EYD028 48EJ,EK,EW,EYD030 4262 1933 69.6 1768 44.0 1118 87.68 2227 48EJ,EK,EW,EYD034 48EJ,EWE028 48EJ,EWE030 4342 1969 70.1 1781 44.3 1125 48EJ,EWE034 48EJ,EK,EW,EYD038 4442 2015 92.7 2355 46.9 1191 48EJ,EWE038 4602 2087 94.1 2390 47.2 1199 48EJ,EK,EW,EYD044 4668 2117 89.3 2268 46.9 1191 150 3810 48EJ,EWE044 4828 2190 90.8 2306 47.2 1199 48EJ,EK,EW,EYD0

Summary of the content on the page No. 10

Table 1 — Physical Data UNIT 48EJ,EK,EW,EY 024D/E 028D/E 030D/E 034D/E NOMINAL CAPACITY (tons) 20 25 27 30 OPERATING WEIGHT (lb)* Unit Al/Al† (Lo Heat/Hi Heat) 4176/4256 4262/4342 4262/4342 4262/4342 Al/Cu† (Lo Heat/Hi Heat) 4396/4476 4482/4562 4482/4562 4482/4562 Roof Curb (14-in. curb) 365 365 365 365 COMPRESSOR Type Ckt 1 06D328 06D328 06D537 06D537 Ckt 2 06D818 06D328 06D328 06D537 Number of Refrigerant Circuits 22 2 2 Oil (oz) (Ckt 1, Ckt 2) 115, 88 115 ea. 115 ea. 115 ea. REFRIGERANT TYPE

Summary of the content on the page No. 11

Table 1 — Physical Data (cont) UNIT 48EJ,EK,EW,EY 038D/E 044D/E 048D/E NOMINAL CAPACITY (tons) 35 40 45 OPERATING WEIGHT (lb)* Unit Al/Al† (Lo Heat/Hi Heat) 4442/4602 4668/4828 4955/5115 Al/Cu† (Lo Heat/Hi Heat) 4727/4887 4953/5113 5335/5495 Roof Curb (14-in. curb) 410 410 410 COMPRESSOR Type Ckt 1 06D537 06EA250 06EA265 Ckt 2 06D537 06EA250 06EA250 Number of Refrigerant Circuits 222 Oil (oz) (Ckt 1, Ckt 2) 115 ea. 224 ea. 304, 224 REFRIGERANT TYPE R-22 Operating Charge (lb-oz) Circuit 1** 34-0

Summary of the content on the page No. 12

Table 2 — Evaporator Fan Motor Data (Units with Starting Serial Numbers 4197 and Later) MOTOR FAN MOTOR FAN BELT UNIT SHEAVE BUSHING SHEAVE BUSHING OUTSIDE MOTOR SHAFT SHAFT MOTOR FAN BELT TENSION SIZE PITCH DIAMETER PITCH DIAMETER BELT HP DIA. SPEED SHEAVE SHEAVE (QUANTITY) (Lb at 48E DIAMETER (in.) DIAMETER (in.) LENGTH (in.) (rpm) .24 in.) (in.) (in.) 5 1.12 717 BK55 4.8 None-1.125 1B5V124 12.4 B-1.9375 BX59 62 5.10 024 10 1.38 924 2BK50 4.4 None-1.375 2B5V86 8.6 B-1.9375 (2) BX51 54 5.21 15

Summary of the content on the page No. 13

Step5—TrapCondensateDrain— See Fig. 3-6 for drain location. Condensate drain is open to atmosphere and must be trapped. Install a trapped drain at the drain lo- cation.Atrap at least 4-in. deep must be used. See Fig. 12. Trap must be installed to prevent freeze-up. Condensatepansareslopedsothatwaterwillcompletely drainfromthecondensatepantocomplywithindoorairqual- ityguidelines.Thecondensatedrainpanisfittedwitha1-in. FPT coupling. Step6—InstallGasPiping— Unitisequippedfor use with natural gas. In

Summary of the content on the page No. 14

Table 3 — Controls Options and Configurations (Non-Thermostat Applications) UNIT CONFIGURATION DEFAULT COOLING DEFAULT HEATING Unoccupied Cooling — 90 F (SPT) Unoccupied Heating — 55 F (SPT) CV or VAV Unit with SPT Sensor Occupied Cooling — NA Occupied Heating — NA CV Unit with SPT Sensor and Remote Unoccupied Cooling — 90 F (SPT) Unoccupied Heating — 55 F (SPT) Start/Stop Switch Occupied Cooling — 78 F (SPT) Occupied Heating — 68 F (SPT) Unoccupied Cooling — 90 F (RAT) Unoccupied Heating — 55 F

Summary of the content on the page No. 15

VARIABLEAIR VOLUME (VAV)APPLICATIONS Features with Stand-Alone Applications— The units, as REMOTE shipped, are operable as stand-alone units with the addition START/STOP of a timeclock to establish unit start and stop times. SWITCH (FIELD-SUPPLIED) Heating and cooling in both on and off modes is con- R trolled to default values by the base unit control. Set points may be changed with appropriate input devices. Y1 The control has an on-board occupancy schedule which Y2 canbeset

Summary of the content on the page No. 16

When a VAV unit with a space temperature sensor is ac- Step 8 — Make Electrical Connections cessedviaacomputer,thefollowingadditionalfeaturesare available: POWERWIRING—Unitsarefactorywiredforthevoltage shown on the unit nameplate. • ability to initiate timed override from T-55 sensors • temperaturecompensatedstarttocalculateearlystarttime When installing units, provide a disconnect per NEC before occupancy (National Electrical Code) of adequate size (MOCP[maxi- • providespacetemperatureresettore

Summary of the content on the page No. 17

17 LEGEND *Where X is the unit control software version number. CCN — Carrier Comfort Network N.O. — Normally Open COM — Common R— Relay D— Diode SIO — Serial Input/Output LED — Light-Emitting Diode SW — Switch N.C. — Normally Closed T— Terminal Fig. 16 — Control Board Diagram

Summary of the content on the page No. 18

Table 4 — Electrical Data COMPRESSOR VOLTAGE POWER COMBUSTION OFM IFM POWER SUPPLY UNIT NOMNAL RANGE EXHAUST FAN MOTOR No. 1 No. 2 SIZE VOLTAGE FLA 48E (3 Ph 60 Hz) Min Max RLA LRA RLA LRA Qty Hp Hp FLA FLA LRA FLA MCA MOCP* (ea) — — 0.96 101.8/100.3 125/125 16.7/ 5 15.2 23.6 41.6 0.96 125.4/123.9 150/150 — — 0.96 115.9/113.1 150/150 30.8/ 208/230 187 254 39.1 228 25.6 160 2 1 5.3 10 28.0 23.6 41.6 0.96 139.5/136.7 175/175 — — 0.96 131.3/127.1 150/150 46.2/ 15 42.0 23.6 41.6 0.96 154.9/150.7 175

Summary of the content on the page No. 19

Table 4 — Electrical Data (cont) COMPRESSOR VOLTAGE POWER COMBUSTION OFM IFM POWER SUPPLY UNIT NOMINAL RANGE EXHAUST FAN MOTOR No. 1 No. 2 SIZE VOLTAGE FLA 48E (3 Ph 60 Hz) Min Max RLA LRA RLA LRA Qty Hp Hp FLA FLA LRA FLA MCA MOCP* (ea) — — 0.96 169.9/167.1 225/200 30.8/ 10 28.0 23.6 41.6 0.96 193.5/190.7 250/225 — — 0.96 185.3/181.1 225/225 46.2/ 208/230 187 254 57.1 266 57.1 266 2 1 5.3 15 42.0 23.6 41.6 0.96 208.9/204.7 250/250 — — 0.96 198.5/193.1 250/250 59.4/ 20 54.0 23.6 41.6 0.96 222.1/

Summary of the content on the page No. 20

Table 4 — Electrical Data (cont) COMPRESSOR VOLTAGE POWER COMBUSTION OFM IFM POWER SUPPLY UNIT NOMINAL RANGE EXHAUST FAN MOTOR No. 1 No. 2 SIZE VOLTAGE FLA 48E (3 Ph 60 Hz) Min Max RLA LRA RLA LRA Qty Hp Hp FLA FLA LRA FLA MCA MOCP* (ea) — — 0.96 223.1/218.9 275/275 46.2/ 15 42.0 23.6 41.6 0.96 246.7/242.5 300/300 — — 0.96 236.3/230.9 300/300 59.4/ 208/230 187 254 69.2 345 69.2 345 4 1 5.3 20 54.0 23.6 41.6 0.96 259.9/254.5 300/300 — — 0.96 251.7/244.9 300/300 74.8/ 25 68.0 23.6 41.6 0.96 275.3/


Alternative user manuals
# User manual Category Download
1 Carrier SINGLE PACKAGE ROOFTOP UNITS ELECTRIC COOLING/GAS HEATING 48EJ User manual Air Conditioner 69
2 Carrier 48SX User manual Gas Heater 10
3 Carrier 48SX024-060 User manual Gas Heater 2
4 Carrier 48TJ016-028 User manual Gas Heater 12
5 Carrier 48GX User manual Gas Heater 3
6 Carrier 48PG16 User manual Gas Heater 1
7 Carrier 58GP User manual Gas Heater 7
8 Carrier COMFORTLINK 48P2 User manual Gas Heater 3
9 Carrier 58DRC User manual Gas Heater 1
10 Carrier 48SS User manual Gas Heater 8
11 Carrier COMFORTLINK P3 User manual Gas Heater 38
12 Carrier COMFORTLINK P5030-100 User manual Gas Heater 0
13 Carrier COMFORTLINK P4 User manual Gas Heater 3
14 Carrier 58GSC User manual Gas Heater 2
15 Carrier SINGLE PACKAGE ROOFTOP 48HC User manual Gas Heater 9