Remington REM10PT user manual

User manual for the device Remington REM10PT

Device: Remington REM10PT
Category: Gas Heater
Manufacturer: Remington
Size: 1.14 MB
Added : 6/19/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Remington REM10PT. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Remington REM10PT.

For your convenience

If looking through the Remington REM10PT user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Remington REM10PT on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Remington REM10PT to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Remington REM10PT User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Remington REM10PT but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Remington REM10PT. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

BLUE FLAME VENT-FREE
PROPANE/LP GAS HEATER
®
OWNER’S OPERATION AND
INSTALLATION MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
REM10PT
10,000 Btu/Hr
Thermostatically-
Controlled Heater
WARNING: Improper installation,
WARNING: If the information in this manual is not
adjustment, alteration, service, or
followed exactly, a fire or explosion may result caus-
maintenance can cause injury or
ing property damage, personal injury, or loss of life.
prope

Summary of the content on the page No. 2

TABLE OF CONTENTS 2 SAFETY INFORMATION TABLE OF CONTENTS TROUBLESHOOTING .............................................................. 13 SAFETY INFORMATION ............................................................ 2 PRODUCT IDENTIFICATION ..................................................... 3 ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 16 SPECIFICATIONS .................................................................... 18 UNPACKING .................................................

Summary of the content on the page No. 3

SAFETY INFORMATION 3 PRODUCT IDENTIFICATION 3 UNPACKING SAFETY INFORMATION Continued 12. Turn off and let cool before servicing. Only a qualified service person should service and repair heater. Any safety screen or guard removed for servicing the 13. Operating heater above elevations of 4,500 feet could cause appliance must be replaced prior to operating the pilot outage. heater. 14. Turn off propane/LP supply when not in use. 15. Check heater for damage before each use. Do not use a dam- Keep

Summary of the content on the page No. 4

LOCAL CODES PRODUCT FEATURES 4 PROPANE/LP SUPPLY INSTALLATION Check Gas Type Locating Heater LOCAL CODES INSTALLATION Install and use heater with care. Follow all local codes. In the absence CHECK GAS TYPE of local codes, use the latest edition of National Fuel Gas Code, ANSI Use only propane/LP gas. If your gas supply is not propane/LP, do Z223.1/NFPA 54*. not install heater. Call dealer where you bought heater for proper *Available from: type heater. American National Standards Institute, Inc.

Summary of the content on the page No. 5

INSTALLATION 5 Thermostat Sensing Bulb 5 Installing Heater To Wall INSTALLATION Continued 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. THERMOSTAT SENSING BULB 4. For thin walls (1/2" or less), insert red key into wall anchor. The thermostat sensing bulb is located inside the heater. Do not Push red key to “pop” open anchor wings (see Figure 5). move this bulb during installation or operation of the heater. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick

Summary of the content on the page No. 6

INSTALLATION Installing Heater To Wall (Cont.) 6 Connecting to Portable Cylinder Gas Supply INSTALLATION Continued 1. Remove 90° gas fitting from hardware bag. Installing Bottom Mounting Screw 2. Apply pipe joint sealant lightly to male NPT threads (see Fig- 1. Locate bottom mounting hole. This hole is near bottom on back ure 10). This will prevent excess sealant from going into pipe. panel of heater (see Figure 9). Excess sealant in pipe could result in clogged heater valves. 2. Mark screw loca

Summary of the content on the page No. 7

INSTALLATION 7 Connecting to Portable Cylinder Gas Supply (Cont.) 7 Connecting To Permanent Gas Supply INSTALLATION Continued 7. Open propane/LP supply valve on propane/LP tank(s) slowly. If installing to a fixed fuel piping system, the installation must Note: If not opened slowly, excess-flow check valve on pro- conform with local codes or, in the absence of local codes, with the pane/LP tank may stop gas flow. If this happens, close pro- National Fuel Gas Code, ANSI Z223.1. pane/LP supply valve

Summary of the content on the page No. 8

INSTALLATION Connecting To Permanent Gas Supply (Cont.) 8 Checking Gas Connections For Permanent Gas Supply INSTALLATION Continued CONNECTING TO PERMANENT GAS SUPPLY CHECKING GAS CONNECTIONS FOR (CONTINUED) PERMANENT GAS SUPPLY Install sediment trap in supply line as shown in Figure 13. Locate WARNING: Test all gas piping and connections sediment trap where it is within reach for cleaning. Locate sediment for leaks after installing or servicing. Correct all leaks trap where trapped matter is no

Summary of the content on the page No. 9

INSTALLATION 9 Checking Gas Connections For Permanent Gas Supply (Cont.) 9 OPERATING HEATER For Your Safety Read Before Lighting Lighting Instructions INSTALLATION OPERATING HEATER Continued FOR YOUR SAFETY READ BEFORE LIGHTING CHECKING GAS CONNECTIONS FOR PERMANENT GAS SUPPLY (CONTINUED) WARNING: If you do not follow these instructions 3. Check all joints from supply tank to equipment shutoff valve exactly, a fire or explosion may result causing prop- (see Figure 15). Apply a noncorrosive leak

Summary of the content on the page No. 10

OFF HI OPERATING HEATER Lighting Instructions 10 To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure OPERATING HEATER Continued 6. With control knob pressed in, push down and release igni- TO TURN OFF GAS tor button. This will light pilot. The pilot is attached to the TO APPLIANCE front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights. Shutting Off Heater Note: If pilot does not stay lit, refer to

Summary of the content on the page No. 11

INSPECTING BURNER 11 Pilot Flame Pattern 11 Burner Flame Heater STORAGE INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an 1/2 GLASS HEIGHT incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to Figure 20 - Correct Burner Flame Pattern cool. When the thermocouple cools, the heater will shut down. Yellow Tipping If p

Summary of the content on the page No. 12

CLEANING AND MAINTENANCE ODS/Pilot and Burner 12 Cleaning Burner Pilot Air Inlet Cabinet CLEANING AND MAINTENANCE Pilot Air Inlet Hole WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have Pilot Assembly heater inspected yearly by a qualified service person. Pilot Assembly CAUTION: You must check and keep burner/ venturi tubes clean of insect and

Summary of the content on the page No. 13

TROUBLESHOOTING 13 13 TROUBLESHOOTING WARNING: Turn off heater CAUTION: Never use a wire, and let cool before servicing. needle, or similar object to clean Note: All troubleshooting items are listed in ODS/pilot. This can damage ODS/ Only a qualified service per- order of operation. pilot unit. son should service and repair heater. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, there is no 1. Ignitor electrode positioned wrong 1. Replace pilot assembly spark at ODS/pilot

Summary of the content on the page No. 14

TROUBLESHOOTING 14 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice is clogged 1. Clean burner orifice (see Cleaning and Maintenance, page 12) or replace burner orifice 2. Inlet gas pressure is too low 2. Contact local propane/LP gas company Delayed ignition of burner 1. Manifold pressure is too low 1. Contact local propane/LP gas company 2. Burner orifice is clogged 2. Clean burner orifice (see Cleaning and Maintena

Summary of the content on the page No. 15

TROUBLESHOOTING 15 15 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, ci

Summary of the content on the page No. 16

ILLUSTRATED PARTS BREAKDOWN REM10PT 16 ILLUSTRATED PARTS 22 BREAKDOWN 21 REM10PT 20 10 14 16 13 19 12 24 10 18 4 11 14 15 7 9 6 3 5 17 8 23 2 1 PILOT For more information, visit www.desatech.com For more information, visit www.desatech.com 110373-01B

Summary of the content on the page No. 17

PARTS LIST 17 REM10PT 17 PARTS LIST REM10PT This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 18 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-03 Front Panel Assembly 1 3 099318-04 Grill Guard 1 4 101108-01 Grill Guard Clip 2 5 102017-02 Bottom Glass Retainer 1 6 098260-11 Glass Panel 1 7 098532-06AA Top Glass Retainer 1 8 M11084-38 Screw, #8 x 3/8" 8 9 0993

Summary of the content on the page No. 18

SPECIFICATIONS 18 TECHNICAL SERVICE SERVICE HINTS SERVICE PUBLICATIONS ACCESSORIES REPLACEMENT PARTS ACCESSORIES SPECIFICATIONS REM10PT Purchase this heater accessory from your local dealer. If they cannot Btu(Variable) 5,000/10,000 supply this accessory, call DESA International at 1-866-672-6040 Type Gas Propane/LP Only for referral information. You can also write to the address listed on the back page of this manual. Ignition Piezo Internal Regulator Setting 8" W.C. Part Number Description Inl

Summary of the content on the page No. 19

19 19 OWNER'S REGISTRATION FORM In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information: Brand: (Comfort Glow, V

Summary of the content on the page No. 20

20 Postage Required TM 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 For more information, visit www.desatech.com For more information, visit www.desatech.com 110373-01B TAPE TAPE


Alternative user manuals
# User manual Category Download
1 Allied Air Enterprises 506271-01 User manual Gas Heater 0
2 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
3 Breckwell ECONOMY P22FSL User manual Gas Heater 0
4 Breckwell ECONOMY P22FSA User manual Gas Heater 0
5 Breckwell ECONOMY P22I User manual Gas Heater 1
6 Briggs & Stratton 32K400 User manual Gas Heater 2
7 Bryan Boilers CLM240WP User manual Gas Heater 2
8 Bryan Boilers CLM180WP User manual Gas Heater 0
9 Bryan Boilers CLM270WP User manual Gas Heater 1
10 Bryan Boilers CLM300WP User manual Gas Heater 0
11 Bryan Boilers CLM90WP User manual Gas Heater 0
12 Cannon CANTFS-03-NG User manual Gas Heater 0
13 Cannon CANTFS-03-LP User manual Gas Heater 0
14 Bryant 585A/YAC User manual Gas Heater 7
15 Bryant 584B User manual Gas Heater 0