Sanyo CH3082 user manual

User manual for the device Sanyo CH3082

Device: Sanyo CH3082
Category: Air Conditioner
Manufacturer: Sanyo
Size: 6.18 MB
Added : 5/29/2014
Number of pages: 109
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo CH3082. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo CH3082.

For your convenience

If looking through the Sanyo CH3082 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo CH3082 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo CH3082 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo CH3082 User manual - Online PDF
Advertisement
« Page 1 of 109 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo CH3082 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo CH3082. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL & SERVICE MANUAL
KHS3082 + CH3082
FILE NO.
KHS3682 + CH3682
Destination: North America
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Indoor Model No. Product Code No. Outdoor Model No. Product Code No.
KHS3082 1 852 354 28 CH3082 1 852 354 32
KHS3682 1 852 354 29 CH3682 1 852 354 33
Indoor Unit Outdoor Unit
KHS3082 CH3082
KHS3682 CH3682
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
REFERENCE NO. SM700858

Summary of the content on the page No. 2

SAFETY PRECAUTIONS • Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious consequence

Summary of the content on the page No. 3

Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. Prohibit If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." Prohibit When th

Summary of the content on the page No. 4

Table of Contents Page SAFETY PRECAUTIONS .............................................................................................................. 2 TABLE OF CONTENTS ..................................................................................................................... 4 1. OPERATING RANGE ................................................................................................................... 6 2. SPECIFICATIONS 2-1. Unit Specifications ..................

Summary of the content on the page No. 5

Page 9. CHECKING ELECTRICAL COMPONENTS 9-1. Measurement of Insulation Resistance ............................................................................... 51 9-2. Checking Continuity of Fuse on PCB Ass'y ......................................................................... 52 10. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT 10-1. Characteristics of New Refrigerant R410A ......................................................................... 53 10-2. Checklist bef

Summary of the content on the page No. 6

1. OPERATING RANGE Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum 95 °F D.B. / 71 °F W.B. 115 °F D.B. Cooling Minimum 67 °F D.B. / 57 °F W.B. 0 °F D.B. Maximum 80 °F D.B. / 67 °F W.B. 75 °F D.B. / 65 °F W.B. Heating _ _ _ Minimum D.B. / W.B. D.B. / 0 °F W.B. 6

Summary of the content on the page No. 7

2. SPECIFICATIONS 2-1. Unit Specifications Indoor Unit KHS3082 Outdoor Unit CH3082 < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 30,600 ( 10,900 to 30,600 ) 33,000 ( 14,000 to 33,000 ) kW 9.0 ( 3.2 to 9.0 ) 9.7 ( 4.1 to 9.7 ) Sensible Capacity 18,600 - BTU/h Latent Capacity BTU/h 12,000 - 3 3 Air Circulation (High) ft /min (m /h) 630 (1,070) 671 (1,140) Moisture Removal (High) Pints/h 9.57 - Available Voltage Range V 187 to 253 Running Amperes A 16.5 ( 5.

Summary of the content on the page No. 8

Indoor Unit KHS3082 Outdoor Unit CH3082 < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 30,600 ( 10,900 to 30,600 ) 33,000 ( 14,000 to 33,000 ) kW 9.0 ( 3.2 to 9.0 ) 9.7 ( 4.1 to 9.7 ) Sensible Capacity 18,600 - BTU/h Latent Capacity BTU/h 12,000 - 3 3 Air Circulation (High) ft /min (m /h) 630 (1,070) 671 (1,140) Moisture Removal (High) Pints/h 9.57 - Available Voltage Range V 187 to 253 Running Amperes A 18.0 ( 5.0 to 18.0 ) 16.8 ( 4.5 to 16.8 ) Power Input

Summary of the content on the page No. 9

Indoor Unit KHS3682 Outdoor Unit CH3682 < 230V > Voltage Rating 230V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 34,000 ( 10,900 to 34,000 ) 36,000 ( 14,000 to 36,000 ) kW 10.0 ( 3.2 to 10.0 ) 10.5 ( 4.1 to 10.5 ) Sensible Capacity 20,700 - BTU/h Latent Capacity BTU/h 13,300 - 3 3 Air Circulation (High) ft /min (m /h) 630 (1,070) 671 (1,140) Moisture Removal (High) Pints/h 10.64 - Available Voltage Range V 187 to 253 Running Amperes A 20.0 ( 5.0 to 20.0 ) 18.2 ( 4.5 to 18.2 ) Power I

Summary of the content on the page No. 10

Indoor Unit KHS3682 Outdoor Unit CH3682 < 208V > Voltage Rating 208V Single-Phase 60Hz Cooling Heating Total Capacity BTU/h 34,000 ( 10,900 to 34,000 ) 36,000 ( 14,000 to 36,000 ) kW 10.0 ( 3.2 to 10.0 ) 10.5 ( 4.1 to 10.5 ) Sensible Capacity 20,700 - BTU/h Latent Capacity BTU/h 13,300 - 3 3 Air Circulation (High) ft /min (m /h) 630 (1,070) 671 (1,140) Moisture Removal (High) Pints/h 10.64 - Available Voltage Range V 187 to 253 Running Amperes A 21.9 ( 5.0 to 21.9 ) 19.9 ( 4.5 to 19.9 ) Power

Summary of the content on the page No. 11

2-2. Major Component Specifications 2-2-1. Indoor Unit Indoor Unit KHS3082 Control PCB Part No. CB-KHS3082 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-8HVPULS4U Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-15/16 / L32-1 (D100/L838) Fan Motor Type DC Motor Model ... Q'ty SIC-39CVL-D847-10 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,370 / 1,450 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Ty

Summary of the content on the page No. 12

Indoor Unit KHS3682 Control PCB Part No. CB-KHS3682 Controls Microprocessor Control Circuit Fuse 250V 3A Remote Control Unit RCS-8HVPULS4U Fan Type Cross-Flow Q'ty ... Dia. and Length inch (mm) 1 ... D3-15/16 / L32-1 (D100/L838) Fan Motor Type DC Motor Model ... Q'ty SIC-39CVL-D847-10 ... 1 No. of Poles 8 Rough Measure RPM (Cool / Heat) 1,370 / 1,450 Nominal Output W 47 Coil Resistance Ohm - (Ambient Temp. 68 °F (20 °C)) Safety Device Type Internal Controller Over-Current Protection Yes Over-H

Summary of the content on the page No. 13

2-2-2. Outdoor Unit Outdoor Unit CH3082 P.C.Board Control P.C.B Noise Filer P.C.B H.I.C.Board Part No. CR-CH3082-F POW-CH3082-B1 HIC-CH3072R-C1 Controls Microprocessor - - Circuit Fuse 400V 3.5A 250V 25A - Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-9RVN273H0H / 2,250W Compressor Oil ... Amount Pints (cc) FV68S ... 2.98 (1,400) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm T - R : 0.169 T - S : 0.169 R - S : 0.169 Safety Device CT (Peak current cut-of

Summary of the content on the page No. 14

Outdoor Unit CH3682 P.C.Board Control P.C.B Noise Filer P.C.B H.I.C.Board Part No. CR-CH3682-F POW-CH3082-B1 HIC-CH3072R-C1 Controls Microprocessor - - Circuit Fuse 400V 3.5A 250V 25A - Compressor Type DC Twin Rotary (Hermetic) Compressor Model / Nominal Output C-9RVN273H0H / 2,500W Compressor Oil ... Amount Pints (cc) FV68S ... 2.98 (1,400) Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm T - R : 0.169 T - S : 0.169 R - S : 0.169 Safety Device CT (Peak current cut-off control) Yes Compre

Summary of the content on the page No. 15

2-3. Other Component Specifications Indoor Unit KHS3082 KHS3682 Outdoor Unit CH3082 CH3682 • Indoor heat exchanger sensor (Model:PTM-D51H-S6-1) • Indoor air temp sensor • Compressor temp sensor (Model:KTEC-35-S121-1) (Model:TKS335B) 10 200 9 180 8 160 7 140 6 120 5 100 4 80 3 60 2 40 1 20 0 0 50 59 68 77 86 95 104 32 50 68 86 104 122 140 158 176 194 (10) (15) (20) (25) (30) (35) (40) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature °F (°C) Temperature °F (°C) • Outdoor

Summary of the content on the page No. 16

3. DIMENSIONAL DATA Indoor Unit KHS3082 KHS3682 Unit: inch(mm) (852-0-0010-19600-0) 16 dia. 3-5/32 41-15/16 (1065) 2-3/32 25/32 1-27/32 1-3/32 2-3/8 7-25/32 5-27/32 9-1/16 (230) (3/32) Wide tube dia. 5/8" (15.88) Drain hose dia. 23/32" (18) Narrow tube dia. 3/8" (9.52) 15-1/8 17-23/32 9-3/32 5-1/2 3-3/4 3-3/4 7-7/8 7/16 3-3/8 2-5/8 2-5/8 6-7/32 5-3/16 16-11/32 16-11/32 17-5/16 17-21/32 19-9/16 22-3/8 dia. 3-5/32 2-3/8 5/16 2-3/4 11-13/16 (300) 11-13/16 4-9/16 1-7/8 23/32 7-23/32 2-11/16 2-3

Summary of the content on the page No. 17

Outdoor Unit CH3082 CH3682 17 AIR INTAKE 6-11/6 25-31/32 4-11/32 2-ID:1-1/4 holes (holes for drain) 2-15/16 4-1/8 8-5/8 2-15/16 2-3/8 Of the 4-ID:1-1/4 holes, use 1 of 2 holes specified for drain use to install the port. 1/2 Use rubber plugs to seal the remaining 3 holes. AIR INTAKE 1/2 AIR DISCHARGE 37-1/32 (940) Refrigerant tubing joint (Liquid tube) Flare connection dia.3/8" (9.52) Refrigerant tubing joint (Gas tube) Flare connection dia.5/8" (15.88) AIR DISCHARGE AIR INTAKE 3/4 Tubing o

Summary of the content on the page No. 18

4. REFRIGERANT FLOW DIAGRAM 4-1. Refrigerant Flow Diagram Indoor Unit KHS3082 Outdoor Unit CH3082 KHS3682 CH3682 Indoor unit Outdoor unit Sub Main Accumulator Accumulator Wide tube service Wide tube valve High pressure switch Muffler O.D H.P. 5/8" (15.88 mm) 4-way valve Electric Narrow expansion tube valve service Narrow tube M valve Cooling cycle (Defrosting cycle) Strainer O.D. 3/8" Heating cycle (9.52 mm) 18 Heat exchanger Heat exchanger Compressor

Summary of the content on the page No. 19

5. PERFORMANCE DATA 5-1. Temperature Charts Indoor Unit KHS3082 Outdoor Unit CH3082 Cooling Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) (1) Low pressure performance chart Lo fan Hi Fan 174 (1.2) 159 (1.1) 145 (1.0) 131 (0.9) 117 (0.8) 104 (0.7) -4 5 14 23 32 41 50 59 68 77 86 95 104 (-20) (-15) (-10) (-5) (0) (5) (10) (15) (20) (25) (30) (35) (40) Outdoor inlet air D.B. temp.°F(°C) (2) Operating current performance chart 28 Lo fan Hi Fan 26 24 22 20 18 16 14 12 10 -4

Summary of the content on the page No. 20

Indoor Unit KHS3082 Outdoor Unit CH3082 Heating Characteristics (RH : 46%, Indoor fan speed : High fan) (60Hz, 230V) (1) High pressure performance chart 494 (3.4) 421 (2.9) 348 (2.4) 275 (1.9) 23 32 41 50 59 68 77 (–5) (0) (5) (10) (15) (20) (25) Outdoor inlet air D.B. temp. °F(°C) (2) Operating current performance chart 19 18 17 16 15 14 13 23 32 41 50 59 68 77 (–5) (0) (5) (10) (15) (20) (25) Outdoor inlet air D.B. temp. °F(°C) (3) Indoor discharge air performance chart 131(55) 122(50) 1


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21