Bunn Dual Voltage Models Starting at Serial #024477 CDBC user manual

User manual for the device Bunn Dual Voltage Models Starting at Serial #024477 CDBC

Device: Bunn Dual Voltage Models Starting at Serial #024477 CDBC
Category: Coffeemaker
Manufacturer: Bunn
Size: 1.53 MB
Added : 2/4/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bunn Dual Voltage Models Starting at Serial #024477 CDBC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bunn Dual Voltage Models Starting at Serial #024477 CDBC.

For your convenience

If looking through the Bunn Dual Voltage Models Starting at Serial #024477 CDBC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bunn Dual Voltage Models Starting at Serial #024477 CDBC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bunn Dual Voltage Models Starting at Serial #024477 CDBC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bunn Dual Voltage Models Starting at Serial #024477 CDBC User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bunn Dual Voltage Models Starting at Serial #024477 CDBC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bunn Dual Voltage Models Starting at Serial #024477 CDBC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for 120V 15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf. CONTENTS Introduction & Warranty .................................................................................... 2 User Notices ......................................................................

Summary of the content on the page No. 3

USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. Optional Field Wiring 120 V, 15.0 A, 1800 W 1PH, 2-Wire, 60HZ #29710.0005 (3 Warmers) CDBC(F)-DV BREWERS Optional Field Wiring #00658.0000 120 V, 12.5 A, 1500 W 1PH, 2-Wire, 60HZ #29710.0006 (No Warmer) CDBC(F) APS-DV BREWERS Optional Field Wiring 120/208-240 V, 15.6-17.5 A, 2980-3850 W 1PH, 3-

Summary of the content on the page No. 4

USER NOTICES (CONT.) #02765.0000 #12364.0000 #00656.0000 29707.1 082803 Page 4

Summary of the content on the page No. 5

Models CDBC-DV, CDBC-APS DV & CDBCF TC-DV ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Requirements for brewers without an attached cord set are as follows: 120V VERSION 120/208-240V VERSION Requires 2-wire, Requires 3-wire, grounded service grounded service rated 120 volts ac, rated 120/208-240 15 amp, single volts ac, 20 amp, phase, 60 Hz. single phase, 60 Hz. ELECTRICAL HOOK-UP CAUTION – Improper electrical installa

Summary of the content on the page No. 6

PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 1 and 620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water 1 inlet fitting is ⁄4" flare. 1 3 NOTE - Bunn-O-Matic recommends ⁄4" copper tubing for installations of less than 25 feet and ⁄8"

Summary of the content on the page No. 7

CLEANING 1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. 2. Check and clean the sprayhead. The sprayhead holes must always remain open. OPERATING CONTROLS ON/OFF SWITCH Pressing the "ON/OFF" switch (indicator glowing) supplies power to the brew station warmer, enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator not glowing) stops tank refilling and br

Summary of the content on the page No. 8

Summary of the content on the page No. 9

Summary of the content on the page No. 10

TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the appl

Summary of the content on the page No. 11

TROUBLESHOOTING (cont.) REFILL CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Will not fill or refill 1. Power off to brewer Press OFF/ON switch on control panel to determine if power is ON. 2. Water shut off Make sure water is ON. 3. Display flashing Brewer has shut down due to mal- function (See Diagnostic Chart in manual, Page 20, or under top lid of brewer). Make sure ON/OFF Switch is "ON" 4. ON/OFF Switch and indicator is lit. Remove the Level Probe and check 5. Lime build up on Probe for lime depos

Summary of the content on the page No. 12

TROUBLESHOOTING (cont.) REFILL CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Fill or refill does not shut "OFF" (ON/ 1. Lime build up on probe Remove Level Probe and check for OFF Switch "ON") lime deposits on tip. Clean and rein- stall. 2. Water Level Probe Sensing Sys- Disconnect the brewer from the tem power source. Disconnect the J3 connector from the control board. Check for continuity from the nut on top of the level probe to pin 1 of the plug, continuity should be present. Pull the temper

Summary of the content on the page No. 13

TROUBLESHOOTING (cont.) HEATING CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper tem- 1. Display flashing Brewer has shut down due to mal- perature function (See Diagnostic Chart in manual, Page 20, or under top lid). IMPORTANT: Make sure no tem- perature tests are taken before the Remove temperature probe and 2. Water not touching temperature ready light is "ON". Tank tempera- grommet. Look into hole on tank probe ture must be stabilized before read- lid. Water must be within

Summary of the content on the page No. 14

TROUBLESHOOTING (cont.) HEATING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper tem- 6. Tank Heater Disconnect the brewer from the perature (cont.) power source. Check for continuity between the white terminal of the IMPORTANT: Make sure no tem- terminal block (or red terminal on perature tests are taken before the 208/240volt models) and the black ready light is "ON". Tank tempera- wire on the relay on the control ture must be stabilized before read- board (Toggle Sw

Summary of the content on the page No. 15

TROUBLESHOOTING (cont.) HEATING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming 1. Lime build up on temperature Inspect probe and tank assembly (cont.) probe, tank or tank heater for excessive lime deposits. Delime as required. 2. Temperature Probe Remove the probe from the grom- met and submerge in a water bath of approximately 70°F(21°C). Con- nect an ohmmeter to pins 3 and 4 of the J3 connector. At 60°F(16°C) the reading should be 15.3k ± 2k OHMS, at 70°F(21°C) th

Summary of the content on the page No. 16

TROUBLESHOOTING (cont.) BREWING CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start 1. Display flashing Brewer has shut down due to mal- function (See Diagnostic Chart in manual, Page 20, or under top lid of brewer). Water lines and valves to the brewer 2. No water must be open. Check for voltage across the termi- 3. No power or incorrect voltage to nals at the terminal block. the brewer The indicator lamp must be lit 4. ON/OFF switch not in the "ON" position Allow brewer to heat un

Summary of the content on the page No. 17

TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) 8. Control board or dispense valve If the switch panel is operating prop- erly, proceed as follows. Attach a voltmeter to the terminals of the dispense solenoid. Connect the brewer to the power source. Turn on the brewer and press the BREW switch. Voltage should be present at the solenoid terminals. If voltage is not present, refer to the wiring diagrams and check the wiring har- ness

Summary of the content on the page No. 18

TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Dripping from sprayhead 1. Lime build up Inspect the tank assembly for ex- cessive lime deposits. Delime as required. 2. Dispense valve Remove the dispense valve and clear any obstructions. Rebuild or re- place the valve if necessary. (See page 24) Weak beverage 1. Sprayhead A clean sprayhead must be used for proper extraction. 2. Water temperature Place an empty brew funnel on an empty decanter beneath the spray- head

Summary of the content on the page No. 19

TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Dry coffee grounds remain in the 1. Sprayhead Make sure sprayhead is present and funnel holes are clear and unobstructed. (See Weak Beverage Page 18) ® 2. Funnel loading The BUNN paper filter must be centered in the funnel and the bed of grounds leveled by shaking gen- tly. 1. Warmer Disconnect the brewer from the power source. Remove the warmer Low beverage serving temperature plate and turn upside down to ex- pose th

Summary of the content on the page No. 20

DIAGNOSTICS Intermittent flashing of the bank of temperature indicators, indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault. FLASHES CAUSE THINGS TO CHECK 1 Dry Plug - In Fault - Water Pressure (Is water shut "OFF"?) Sheath of temperature probe dry for 10 minutes after power-up Temperature probe wiring Fill valve wiring, function, & strainer Green wire between tank and circuit board 2 Low Tank Level Fault - Water pre


Alternative user manuals
# User manual Category Download
1 Bunn AUTOMATIC CEZF15 User manual Coffeemaker 6
2 Bunn 5S User manual Coffeemaker 0
3 Bunn CWT15 User manual Coffeemaker 12
4 Bunn CEZF User manual Coffeemaker 0
5 Bunn AutoPOD User manual Coffeemaker 3
6 Bunn A10 Automatic User manual Coffeemaker 41
7 Bunn IMIX-4 User manual Coffeemaker 0
8 Bunn 1.5 GALLON User manual Coffeemaker 6
9 Bunn 120/208V User manual Coffeemaker 17
10 Bunn 10 Cup Pourover Coffee Brewer A10 User manual Coffeemaker 20
11 Bunn CDBC-TSR User manual Coffeemaker 0
12 Bunn 12 CUP AUTOMATIC COFFEE BREWER RL35 User manual Coffeemaker 7
13 Bunn 37614 041410 User manual Coffeemaker 3
14 Bunn COFFEE BREWERNHB User manual Coffeemaker 2
15 Bunn AXIOM BREWWISE 39131.0004B User manual Coffeemaker 45
16 Philips coffee maker flavor select HD7606 User manual Coffeemaker 3
17 Sony WALKMAN D-EJ2000 User manual Coffeemaker 19
18 Philips HD 7820/65 User manual Coffeemaker 62
19 Philips coffee maker flavor select HD7612 User manual Coffeemaker 91
20 Philips HD7544 User manual Coffeemaker 8