Sanyo KS0951 user manual

User manual for the device Sanyo KS0951

Device: Sanyo KS0951
Category: Air Conditioner
Manufacturer: Sanyo
Size: 1.06 MB
Added : 11/14/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Sanyo KS0951. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Sanyo KS0951.

For your convenience

If looking through the Sanyo KS0951 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Sanyo KS0951 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Sanyo KS0951 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Sanyo KS0951 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Sanyo KS0951 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Sanyo KS0951. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTION MANUAL
COOL/DRY Model
Split System Air Conditioner KS0951
KS1251
KS1852
Save These Instructions!
Pub. OI-85264180330005 ©SANYO 2002 Printed on Recycled Paper

Summary of the content on the page No. 2

Features This air conditioner is equipped with cooling and drying functions. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • • Microprocessor Controlled Operation Air Sweep Control The interior compartment of the remote control This function moves a flap up and down in the unit contains several features to facilitate air outlet, directing air in a sweeping motion automatic operation, each logically displayed for around the room a

Summary of the content on the page No. 3

Contents Page Features..................................................................................................................2 Product Information..............................................................................................3 Alert Symbols........................................................................................................3 Installation Location..............................................................................................4 Electrical

Summary of the content on the page No. 4

InstallationLocation • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. • Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse. • Do not install the air cond

Summary of the content on the page No. 5

NamesofParts INDOOR UNIT Air intakes Air outlet Remote control unit Drain hose Refrigerant tubes OUTDOOR UNIT Air outlet This illustration is based on the external appearance of a standard model. NOTE Consequently, the shape may differ from that of the air conditioner which you have selected. This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit. Air Intakes Air from the room is drawn into these sections and passes t

Summary of the content on the page No. 6

Unit Display and Operation Selector Operation selector INDOOR UNIT INDOOR UNIT KS1852 KS0951 KS1251 ON ON OFF TEST OFF TEST Operation selector OPERATION lamp TIMER lamp Remote control receiver OPERATION TIMER Remote control receiver OPERATION TIMER IMPORTANT Avoid using radio equipment such as mobile phones near (within 4 ft. of) the indoor unit. Some radio equipment may cause the unit to malfunction. TIMER lamp OPERATION lamp If the trouble occurs, disconnect power and restart the air condition

Summary of the content on the page No. 7

Remote Control Unit (Display) “ROOM TEMP” is displayed when the temperature setting has not been made. Displayed when main unit sensor is in use “TEMP” is displayed when setting temperature. Displayed when transmitting data Displayed when temperature is shown Displayed when the temperature setting is at the upper or lower allowable limit Displayed when setting timer Symbols (1) Operation mode (4) Timer 24-hour clock with ON/OFF program Timer ....................... MILD DRY.....................

Summary of the content on the page No. 8

Remote Control Unit Sensor Transmitter Display (Cover closed) NIGHT SETBACK button ON/OFF operation button 1 HR. TIMER button Temperature setting buttons MODE selector button FAN SPEED selector button FLAP button TIMER SELECT button TIMER AND PRESENT TIME setting buttons PROGRAM button ADDRESS switch ACL button SENSOR button Battery compartment (Pull off the cover to expose the batteries.) NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed.

Summary of the content on the page No. 9

Remote Control Unit (continued) Program button For details, see “Setting the Timer” . Press this button to select the mode you want to program. TIMER SELECT button No display : The timer does not operate. : The air conditioner stops at the set time. : The air conditioner starts at the set time. : The air conditioner stops and starts, or starts and stops, at the set times every day. MODE selector button Use this button to select the DRY or COOL mode. (DRY) : The air conditioner reduces the humidi

Summary of the content on the page No. 10

Using the Remote Control Unit How to Install Batteries 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ACL button • The batteries last about six months, depending on how much you use NOTE the remote control unit. Replace the batteries when the remote control unit's display fails to

Summary of the content on the page No. 11

Using the Remote Control Unit (continued) Mounting the Remote Control Unit Truss-head tapping screws 5/32 x 5/8 “ (4 x 16 mm) (supplied) Press Remote control unit holder Hook When attaching to wall 1) Confirm the indoor unit beeps when the ON/OFF button is pressed at the wall location where the remote control unit is to be attached, then attach the holder to the wall. 2) When taking out the remote control unit, pull it from the holder. • When using the remote Point the transmitter on the remote

Summary of the content on the page No. 12

Operation with the Remote Control Unit 1. Manual Operation STEP 2 STEP 3 STEP 1 STEP 4 STEP 5 Check that the circuit breaker on the power panel is turned on and that the NOTE operation selector of the indoor unit is in the ON position. Press the setting buttons as described below and change the settings as desired. STEP 1 Press the MODE selector button and select the desired mode. For drying operation → → For cooling operation To start the air conditioner, press the ON/OFF STEP 2 operation butto

Summary of the content on the page No. 13

Operation with the Remote Control Unit (continued) • This appliance has a built-in three minutes time delay circuit to ensure NOTE reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. When the power is restored, the unit will restart automatically after five minutes. 2. Adjusting the Fan Speed A. Automatic Simply set the FAN SPEED selector button to the position. A microcompu

Summary of the content on the page No. 14

Operation with the Remote Control Unit (continued) 3. Night Setback Mode The Night Setback Mode is used for saving energy. Press the NIGHT SETBACK button while the air conditioner is operating. The mark appears in the display. To cancel the night setback function, press the NIGHT SETBACK button again. In Cooling and DRY Mode: When the night setback mode is selected, the air conditioner ( and ) automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was m

Summary of the content on the page No. 15

Special Remarks ``DRY'' ( ) Operation • How it works? Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. • During DRY operation, the fan speed is automatically set to LOW or VERY LOW; the fan speed then switches back and forth between LOW (for 20 seconds) and VERY LOW (for 10 seconds). • “DRY” operation is not possible if the indoor temperature is 59 °F or less. • In the event of power failure, the unit will stop. When the po

Summary of the content on the page No. 16

Setting the Timer 3 4 2 1 1. How to set the (Example) To set to 9:10 pm. present time Operation Indication 1. Press the Program button ( ) The time indication alone blinks. three times. 2. • Press the HH button until PM 9 is The display will automatically displayed. stop blinking except for the “:” symbol after 10 sec. • Press the MM button until 10 is displayed. (Example) To stop the air conditioner at 11:30 pm. 2. How to set the OFF time The timer indication blinks 1. Press the Program button

Summary of the content on the page No. 17

Setting the Timer (continued) (Example) To start operation at 7:10 am. 3. How to set the ON time Operation Indication 1. Press the Program button ( ) The timer indication blinks twice. and present ON time is shown. • 2. Press the HH button until AM 7 is The display will change displayed. automatically back to show the present time after 10 sec. • Press the MM button until 10 is displayed. 3. Press the ON/OFF button to start the The present time is displayed. air conditioner. 4. Press the TIMER

Summary of the content on the page No. 18

Setting the 1-Hour OFF Timer 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button. appears in the display. Cancellation procedure: Press the ON/OFF operation button to turn the unit off, wait for the unit to stop

Summary of the content on the page No. 19

Adjusting the Airflow Direction 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. When the humidity is high, the vertical vanes should be in the front CAUTION position during the cooling or drying operation. If the vertical vanes are positioned all the way to the right or left, condensation may begin to form around the air vent and drip down. 2. Vertical The vertical airflow can be adjusted by moving the flap with the remote

Summary of the content on the page No. 20

Operation without the Remote Control Unit INDOOR UNIT KS0951 KS1251 If you have lost the remote control unit or it has trouble, follow the steps below. ON OFF 1. When the air conditioner is not running TEST If you want to turn on the air conditioner, switch the operation selector to the OFF position, and then to the ON position. Operation The set temperature and fan speed are automatically set at the NOTE selector last selection before stopping. KS1852 2. When the air conditioner


Alternative user manuals
# User manual Category Download
1 Sanyo 000-24 User manual Air Conditioner 1135
2 Sanyo 09KLS51 User manual Air Conditioner 370
3 Sanyo 09KLS71 User manual Air Conditioner 160
4 Sanyo 000-31 User manual Air Conditioner 76
5 Sanyo 09KS51 User manual Air Conditioner 136
6 Sanyo 09KS71 User manual Air Conditioner 23
7 Sanyo 12KLS51 User manual Air Conditioner 22
8 Sanyo 12KS71 User manual Air Conditioner 18
9 Sanyo 12KLS71 User manual Air Conditioner 8
10 Sanyo 09KHS71 User manual Air Conditioner 22
11 Sanyo 12KS51 User manual Air Conditioner 14
12 Sanyo 12KHS32 User manual Air Conditioner 29
13 Sanyo 12RLS11 User manual Air Conditioner 10
14 Sanyo 12KHS71 User manual Air Conditioner 13
15 Sanyo 12XLS71 User manual Air Conditioner 9
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21