Dell ? PowerEdge 6800 user manual

User manual for the device Dell ? PowerEdge 6800

Device: Dell ? PowerEdge 6800
Category: Computer Accessories
Manufacturer: Dell
Size: 9.75 MB
Added : 3/16/2014
Number of pages: 126
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dell ? PowerEdge 6800. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dell ? PowerEdge 6800.

For your convenience

If looking through the Dell ? PowerEdge 6800 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dell ? PowerEdge 6800 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dell ? PowerEdge 6800 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dell ? PowerEdge 6800 User manual - Online PDF
Advertisement
« Page 1 of 126 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dell ? PowerEdge 6800 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dell ? PowerEdge 6800. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Dell™ PowerEdge™ 6800 Systems
Information Update
信息更新
Mise à jour des informations
Aktuelle Informationen
アップデート情報
설명서 갱신본
Actualización de información
www.dell.com | support.dell.com

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Dell™ PowerEdge™ 6800 Systems Information Update www.dell.com | support.dell.com

Summary of the content on the page No. 4

Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death. ____________________ Information in this document is subject to change without notice. © 2006 Dell Inc. All rights reserved. Reproduction in any manner whatsoever wi

Summary of the content on the page No. 5

Information Update This document provides information for your system on the following topics:  Reconfiguring the system for regional power requirements  Processor upgrades  Adaptec SCSI Card 39160 expansion-card slot restrictions  System start-up behavior  Integrated NIC IPMI port functionality  Remote Access Controller card interaction with integrated video  System messages  Environmental data sheets  Removing and installing the cooling shroud  Linux operating system information ® ®

Summary of the content on the page No. 6

Reconfiguring the System for Regional Power Requirements CAUTION: If you relocate a system operating in the 120–127 VAC or 200–240 VAC range to a different geographic area, ensure that jumper CB_TYPE matches the AC line voltage range of your new location. If the new power source is less than 120 VAC and you do not reconfigure jumper CB_TYPE for the lower voltage power source, damage to the system power cable or the system itself may occur. Table 1-1 lists countries where the AC line voltage

Summary of the content on the page No. 7

Figure 1-1. Power Configuration Jumper Location Processor Upgrades If you add one or more processors to your system, ensure that all processors have the same stepping value and the same cache size and technology. If you install processors with different speeds, they will operate at the speed of the slowest processor. You must install all voltage regulator modules (VRMs) included in the upgrade kit, in addition to the processors. See "Processors" in your Installation and Troubleshooting Guide

Summary of the content on the page No. 8

System Start-Up Behavior The following system behaviors during system start-up are normal and do not indicate a problem with the system:  When AC power is applied to the system, if the System Setup program’s AC Power Recovery option is not set to allow the system to power up when AC power is applied, the cooling fans will spin-up briefly and then stop. (See your User’s Guide for information on the System Setup program.)  It may take 30 seconds or longer for video to display after the system

Summary of the content on the page No. 9

Table 1-3. LCD Status Messages Line 1 Line 2 Causes Corrective Actions Message Message SYSTEM SYSTEM NAME SYSTEM ID is a unique name, This message is for information ID five characters or less, defined by only. the user. You can change the system ID SYSTEM NAME is a unique and name in the System Setup name, 16 characters or less, program. See your User's Guide defined by the user. for instructions. The system ID and name display under the following conditions:  The system is powered on. 

Summary of the content on the page No. 10

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0119 TEMP PLANAR System board temperature is out See "Troubleshooting System of acceptable temperature range. Cooling Problems" in your Installation and Troubleshooting Guide. E0212 PROC VTT Processor VTT voltage is out See "Troubleshooting Power of acceptable voltage range. Supplies" in your Installation and Troubleshooting Guide. E0212 VOLT PG n System power supply is out of See "Troublesho

Summary of the content on the page No. 11

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0276 VRM # PG The voltage of the specified VRM See "Troubleshooting the is out of acceptable range. Microprocessors" in your Installation and Troubleshooting Guide. If the problem still persists, see "Getting Help" in your Installation and Troubleshooting Guide. E0276 VCACHE # PG The voltage of the specified See "Troubleshooting the VCACHE is out of acceptable Microprocessors" in your rang

Summary of the content on the page No. 12

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0780 PROC n PRESENCE Microprocessor is not installed Install a microprocessor in socket in socket n. n. See "Installing a Processor" in your Installation and Troubleshooting Guide. E07F0 PROC n IERR Faulty or improperly installed See "Troubleshooting the microprocessor. Microprocessors" in your Installation and Troubleshooting Guide. E07FA PROC n THERMTRIP Specified microprocessor is out See

Summary of the content on the page No. 13

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message E0880 PS REDUNDANCY Power supply redundancy has Reinstall the power supply LOST been lost because a power supply to restore redundancy. has been removed from the system. E0D76 BP DRIVE n Faulty or improperly installed See "Troubleshooting SCSI Hard hard drive or RAID controller. Drives," "Troubleshooting a RAID Controller Card," and "Troubleshooting the Integrated RAID Controller" in your In

Summary of the content on the page No. 14

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message EB10C ECC UNCORR ERR Uncorrectable ECC errors have See "Troubleshooting System occurred in system memory. The Memory" in your Installation ECC UNCORR ERR affected memory bank may be and Troubleshooting Guide. BANK # specified. EB113 I/O CHANNEL CHK System I/O channel check error See "Getting Help" in your has occurred. Installation and Troubleshooting Guide. EB113 PCI PARITY ERR PCI parity err

Summary of the content on the page No. 15

Table 1-3. LCD Status Messages (continued) Line 1 Line 2 Causes Corrective Actions Message Message EB113 CHIPSET ERR An error has occurred in the See "Troubleshooting the chipset. Microprocessors" in your Installation and Troubleshooting Guide. If the problem persists, see "Troubleshooting Expansion Cards" in your Installation and Troubleshooting Guide. If the problem still persists, see "Getting Help" in your Installation and Troubleshooting Guide. EFFF2 ROMB PRESENCE Integrated RAID

Summary of the content on the page No. 16

Removing and Installing the Cooling Shroud To remove the cooling shroud, grasp each end of the shroud and lift the shroud straight up from the system. To install the cooling shroud, slowly lower the shroud straight down into the system and then press down on the four icons (above the latches) until the shroud snaps into place. See Figure 1-2. Figure 1-2. Removing and Installing the Cooling Shroud icons (4) cooling shroud latches (4) 14 Information Update

Summary of the content on the page No. 17

Linux Operating System Information Booting Red Hat Enterprise Linux AS (Version 4) for Intel x86 With More than Eight Logical Processors A system running the Red Hat Enterprise Linux AS (version 4) for Intel x86 operating system will fail to boot if it is configured with more than eight logical processors. To work around this issue, pass the parameter apic=bigsmp to the kernel command line at system boot. A correction for this issue will be available in a future Red Hat Enterprise Linux Vers

Summary of the content on the page No. 18

Microsoft Windows 2000 Installation Installation of Microsoft Windows 2000 Server or Microsoft Windows 2000 Advance Server is not supported on PowerEdge 6800 systems featuring dual-core processors with L3 cache. NOTE: Installation of Microsoft Windows 2000 Server or Microsoft Windows 2000 Advanced Server is supported on PowerEdge 6800 systems featuring single-core processors (with or without L3 cache) and dual-core processors with L2 cache only. The processor type can be obtained by one of t

Summary of the content on the page No. 19

™ ™ Dell PowerEdge 6800系统 信息更新 www.dell.com | support.dell.com

Summary of the content on the page No. 20

注、注意和警告 注:注表示可以帮助您更好地使用计算机的重要信息。 注意:注意表示可能会损坏硬件或导致数据丢失,并告诉您如何避免此类问题。 警告:警告表示可能会导致财产损失、人身伤害甚至死亡。 ____________________ 本文件中的信息如有更改,恕不另行通知。 © 2006 Dell Inc.版权所有,翻印必究。 未经 Dell Inc. 书面许可,严禁以任何形式进行复制。 本文中使用的商标:Dell、DELL 徽标和 PowerEdge 是 Dell Inc. 商标; Intel 是 Intel Corporation 的注册商标; Microsoft 和 Windows 是 Microsoft Corporation 的注册商标,Windows Server 是 Microsoft Corporation 的商标; Red Hat 是 Red Hat Corporation 的注册商 标; SUSE 是 SUSE LINUX Products GmbH 的注册商标。 本文件中述及的其它商标和产品名称是指拥有相应商标和名称的公司或其制造的产品。Dell Inc.


Alternative user manuals
# User manual Category Download
1 Dell 3448 User manual Computer Accessories 1
2 Dell AY511 User manual Computer Accessories 2
3 Dell 3700 User manual Computer Accessories 13
4 Dell 64XX User manual Computer Accessories 1
5 Dell 8400 User manual Computer Accessories 4
6 Dell 650 User manual Computer Accessories 3
7 Dell IN2030MF User manual Computer Accessories 6
8 Dell IN1930 User manual Computer Accessories 0
9 Dell 3424P User manual Computer Accessories 0
10 Dell CPI User manual Computer Accessories 1
11 Dell R320 User manual Computer Accessories 0
12 Dell 3448P User manual Computer Accessories 0
13 Dell 34XX User manual Computer Accessories 0
14 Dell MD3220 User manual Computer Accessories 6
15 Dell IN1930F User manual Computer Accessories 1
16 Sony VGC-RB50(G) User manual Computer Accessories 1
17 Sony Movie Studio HD Platinum Suite 11 MSPSMS11000 User manual Computer Accessories 177
18 Sony Hi-MD Walkman MCMD-R1 User manual Computer Accessories 7
19 Sony Sound Forge V.10.0 Pro SF-10000 User manual Computer Accessories 435
20 Sony Rechargable Battery Pack VGP-BPSC31 User manual Computer Accessories 23