Grizzly G0572 user manual

User manual for the device Grizzly G0572

Device: Grizzly G0572
Category: Air Cleaner
Manufacturer: Grizzly
Size: 3.32 MB
Added : 12/21/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Grizzly G0572. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Grizzly G0572.

For your convenience

If looking through the Grizzly G0572 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Grizzly G0572 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Grizzly G0572 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Grizzly G0572 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Grizzly G0572 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Grizzly G0572. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HANGING AIR FILTER
WITH REMOTE
MODEL G0572
INSTRUCTION MANUAL
COPYRIGHT © JANUARY, 2005 BY GRIZZLY INDUSTRIAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE
OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
#BL6810 PRINTED IN CHINA

Summary of the content on the page No. 2

WARNING Some dust created by power sanding, sawing, grind- ing, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are: • Lead from lead-based paints. • Crystalline silica from bricks, cement, and other masonry products. • Arsenic and chromium from chemically treated lumber. Your risk from these exposures varies, depending on how often yo

Summary of the content on the page No. 3

Table of Contents INTRODUCTION ............................................................................................................................... 2 Foreword .................................................................................................................................... 2 Contact Info ................................................................................................................................ 2 SECTION 1: SAFETY .................................

Summary of the content on the page No. 4

INTRODUCTION Foreword Contact Info We are proud to offer the Model G0572 Hanging If you have any comments regarding this manual, Air Filter with Remote. This machine is part of please write to us at the address below: a growing Grizzly family of fine woodworking machinery. When used according to the guide- Grizzly Industrial, Inc. C lines set forth in this manual, you can expect /O Technical Documentation years of trouble-free, enjoyable operation and P.O. Box 2069 proof of Grizzly’s commi

Summary of the content on the page No. 5

MACHINE DATA SHEET Customer Service #: (570) 546-9663 • To Order Call: (800) 523-4777 • Fax #: (800) 438-5901 MODEL G0572 HANGING AIR FILTER WITH REMOTE Overall Dimensions: 1 Unit Dimensions (L x W x H) ...................................... 26" x 19 ⁄4" x 15" Shipping Weight .........................................................................64 lbs. Installed Weight ......................................................................... 55 lbs. Capacities: Air Flow at Low Speed ....

Summary of the content on the page No. 6

SECTION 1: SAFETY For Your Own Safety, Read Instruction Manual Before Operating this Machine The purpose of safety symbols is to attract your attention to possible hazardous conditions. This manual uses a series of symbols and signal words which are intended to convey the level of importance of the safety messages. The progression of symbols is described below. Remember that safety messages by themselves do not eliminate danger and are not a substitute for proper accident prevention measure

Summary of the content on the page No. 7

Safety Instructions for Machinery 7. ONLY ALLOW TRAINED AND PROP- 16. MAKE SURE GUARDS ARE IN PLACE ERLY SUPERVISED PERSONNEL TO AND WORK CORRECTLY BEFORE OPERATE MACHINERY. Make sure USING MACHINERY. operation instructions are safe and clearly understood. 17. REMOVE ADJUSTING KEYS AND WRENCHES. Make a habit of checking for 8. KEEP CHILDREN AND VISITORS AWAY. keys and adjusting wrenches before turn- Keep all children and visitors a safe dis- ing machinery ON. tance from the work area. 18

Summary of the content on the page No. 8

Additional Safety for Hanging Air Filters 1. FILTER CAPABILITIES. DO NOT allow 6. MINIMIZING DUST EXPOSURE. Use a this air filter unit to operate in an environ- respirator along with a dust collection sys- ment that has volatile fumes from fuels, tem when operating woodworking machin- paints, pesticides, chemicals, smoke; and ery, and keep the filters of your air filter never operate in an environment that has unit clean for optimum performance to particles of silica, metal, asbestos, or min

Summary of the content on the page No. 9

SECTION 2: CIRCUIT REQUIREMENTS Plug Type 110V Operation The Model G0572 is supplied with a 5-15 plug, similar to Figure 1. Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so. Amperage Draw 1 The ⁄5 HP motor on the Model G0572 will draw the following amps on the highest setting: Motor Load ..............................................3 Am

Summary of the content on the page No. 10

Grounding Extension Cords We do not recommend using an extension cord In the event of an electrical short, grounding with most equipment because the cord can reduces the risk of electric shock by providing generate heat that may cause fire or circuit a path of least resistance to disperse electric damage. If you must use an extension cord, use current. This tool is equipped with a power cord the guidelines below. that has a plug with an equipment-grounding prong. The outlet must be p

Summary of the content on the page No. 11

SECTION 3: SET UP Set Up Safety Items Needed For Set Up The following items may be needed to complete This machine presents the set up process, depending upon how you plan serious injury hazards to set up your air filter, but are not included: to untrained users. Read through this entire manu- DESCRIPTION QTY al to become familiar with • Phillips Head Screwdriver .......................... 1 the controls and opera- • Safety Glasses (for each person) .............. 1 tions before starting

Summary of the content on the page No. 12

Inventory A After all the parts have been removed from the two boxes, you should have the following items: Components (Figure 2) QTY C A. Model G0572 Hanging Air Filter ................. 1 B B. Primary Filter (5-Micron, Pleated-Type) ..... 1 C. Secondary Filter (1-Micron, Bag-Type) ...... 1 Remote Control and Mounting Hardware (Figure 3) D. Hand-Held Remote Control Unit ................ 1 Figure 2. Model G0572 Hanging Air Filter and E. AAA Batteries .........................................

Summary of the content on the page No. 13

Hardware Recognition Chart -11- G0572 Hanging Air Filter with Remote

Summary of the content on the page No. 14

Shop Preparation Site Planning Machine Mobility Site planning is an important step to maximize the The Model G0572 has a balanced fan and uses effectiveness of the hanging air filter. Air circulation digital components that are sensitive to jarring. must be thought out and all obstructions to the air Move this air filter unit with care, and do not drop path considered. or handle it roughly. Think of air circulation in terms of the circular Operating Location motion of the air before and

Summary of the content on the page No. 15

Figure 5 shows an example of poor air circulation, Filter Capacity where the air filter is placed too close to obstruc- tions. In this situation, the velocity of the air is lost and circulation is diminished. The G0572 Hanging Air Filter with Remote will recirculate the entire volume of air in a room measuring 25' X 25' X 8' approximately 12 times in one hour. We recommend that the volume of air in your room be recirculated at least 6-8 times every hour. To calculate the recirculating ra

Summary of the content on the page No. 16

Dust System Mounting Preparation When used in conjunction with a dust collector system, the Model G0572 filter efficiently removes It is very important that the hanging air filter most fine wood particles in the air that many dust be supported properly. Please use these guide- collectors cannot. lines when preparing to mount the unit: • For the sake of clarity, the face where the mounting eye bolts and flush mount USE the correct dust collection system in flange brackets attach will b

Summary of the content on the page No. 17

Beginning Mounting Keep the air filter unit ! unplugged during all You can install the air filter unit one of the installation procedures. following ways: Ignoring this warning may result in serious personal • Table-Top Mount: Use the rubber feet and/or injury to you or others! the flush mount flange brackets (see Figures 6 & 7) for a table-top application). • Hanging Mount: Use the eye bolts (see Figures 6 & 7) for a high ceiling application. Refer to Page 16. Table-Top Mount • Flus

Summary of the content on the page No. 18

To make the unit operate at the optimum height Flange Bracket Mounting Rubber Feet of 7' from the floor, you can install the air filter Holes unit in your shop by hanging it by chain, cable, or steel strapping. ONLY hang the air filter to load bearing ceil- ing studs or joists that can hold at least 100 lbs. DO NOT mount the unit to sheet rock, pressboard, paneling, or honeycomb ceil- ing panels with expansion-type fasteners like the ones shown in Figure 9. The fasten- ers can tear out a

Summary of the content on the page No. 19

2. Remove the plug screw. Retain the screws, Flush Mount because if you remove the eye bolts for the flush mounting configuration, you must reinstall these screws to seal the air filter unit. (Figure Components and Hardware Needed Qty 10). Mounting Brackets ............................................. 4 1 1 Hex Bolts ⁄4"-20 X ⁄4" ........................................ 8 Optional Plug Screw 1 ⁄4" Lag Bolts ...................................................... 4 1 ⁄4" Nuts .............

Summary of the content on the page No. 20

1 2. Drill the bolt pattern to accept at least ⁄4" lag 4. Install the flat washers and the hex bolts to 1 bolts for studs; or use ⁄4" nuts, bolts, and secure the flange brackets to the unit (Figure washers for mounting to supports. 14). 3. Position the flange bracket under the air filter Flange Bracket unit lip at the mounting hole location (Figure Mounted Under Lip 12). For permanent table-top mounting, use the lower-lip holes (Figure 13). Lip Mounting holes Flange Bracket Figure 14. F


Alternative user manuals
# User manual Category Download
1 Grizzly G4702 User manual Air Cleaner 5
2 Grizzly Heavy Duty Hanging Air Filter G5955 User manual Air Cleaner 1
3 Grizzly G4705 User manual Air Cleaner 1
4 Grizzly G0573 User manual Air Cleaner 2
5 Grizzly HEAVY-DUTY DOUBLE AIR FILTER G9956 User manual Air Cleaner 3
6 Sony PK-HS1FL User manual Air Cleaner 1920
7 Sony PK-R1FL User manual Air Cleaner 11
8 Philips AC4053 User manual Air Cleaner 30
9 Philips AC4002/00 User manual Air Cleaner 13
10 Philips AC4055 User manual Air Cleaner 9
11 Philips AC4054 User manual Air Cleaner 13
12 Philips AC4004/00 User manual Air Cleaner 21
13 Philips AC4055/00 User manual Air Cleaner 10
14 Philips AC4062 User manual Air Cleaner 5
15 Philips AC4054/00 User manual Air Cleaner 5