York AFFINITY R-410A user manual

User manual for the device York AFFINITY R-410A

Device: York AFFINITY R-410A
Category: Air Conditioner
Manufacturer: York
Size: 1.27 MB
Added : 6/10/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York AFFINITY R-410A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York AFFINITY R-410A.

For your convenience

If looking through the York AFFINITY R-410A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York AFFINITY R-410A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York AFFINITY R-410A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York AFFINITY R-410A User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York AFFINITY R-410A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York AFFINITY R-410A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

R-410A
AFFINITY SERIES
DEX024-048

DEY060

2-5 Ton
TABLE OF CONTENTS
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
L

Summary of the content on the page No. 2

288429-YIM-A-0307 Wear safety glasses and work gloves. Use quenching cloth and have a fire extinguisher available during brazing operations. Inspection This product must be installed in strict compliance with As soon as a unit is received, it should be inspected for possible the installation instructions and any applicable local, damage during transit. If damage is evident, the extent of the state and national codes including, but not limited to damage should be noted on the carrier’s freight

Summary of the content on the page No. 3

288429-YIM-A-0307 Refer to Table 6 for unit physical data and to Table 5 for electrical Installation data. Limitations If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer's These units must be installed in accordance with the following expense. national and local safety codes. 1. National Electrical Code ANSI/NFPS No. 70 or Canadian Size of unit for proposed installation should be based on heat Electrical Code Part 1, C2

Summary of the content on the page No. 4

288429-YIM-A-0307 Location Rigging And Handling Use the following guidelines to select a suitable location for Exercise care when moving the unit. Do not remove any these units. packaging until the unit is near the place of installation. Rig the unit by attaching chain or cable slings to the lifting holes 1. Unit is designed for outdoor installation only. provided in the base rails. Spreader bars, whose length 2. Condenser must have an unlimited supply of air. Where a exceeds the largest di

Summary of the content on the page No. 5

288429-YIM-A-0307 Table 2: Unit Accessory Weights Weight (lbs.) Unit Accessory Model Shipping Operating Add Economizer All 45 40 1 Add Electric Heat All 13 12 1. Weight given is for the maximum heater size available (25 kW). Figure 3: Unit Dimensions Table 3: Unit Dimensions Front Dimensions Unit Size “A” 024, 030, 036 33-1/2 1 042, 048, 060 41-1/2 1. DEY Models Table 4: Unit Clearances Distance Distance Direction Direction (in.) (in.) 1 Top 36

Summary of the content on the page No. 6

288429-YIM-A-0307 Figure 4: Dimensions Front and Bottom Figure 5: Dimensions Back and Bottom 6 Unitary Products Group

Summary of the content on the page No. 7

288429-YIM-A-0307 1 Figure 6: Roof Curb Ductwork NOTE: Be sure to note supply and return openings. Refer to Figures 4 and 5 for information concerning rear and These units are adaptable to downflow use as well as rear bottom supply and return air duct openings. supply and return air duct openings. To convert to downflow, use the following steps: Roof Curb 1. Remove the duct covers found in the bottom return and On applications when a roof curb is used, the unit must b

Summary of the content on the page No. 8

288429-YIM-A-0307 Service Access Thermostat Access to all serviceable components is provided at the The room thermostat should be located on an inside wall following locations: approximately 56" above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or • Blower compartment access panel appliances. Follow manufacturer's instructions enclosed with • Electrical/Filter access panel the thermostat for general installation procedure. Six color • Comp

Summary of the content on the page No. 9

288429-YIM-A-0307 NOTE: HEAT ANTICIPATOR SHOULD BE SET AT 0.35 2 STAGE UNIT CONTROL BOARD AMPS FOR ALL MODELS. THERMOSTAT TERMINAL STRIP ** = Minimum wire size of 18 AWG ** R R wire should be used for all field installed 24 volt wire. G G Y1 Y1 24 VOLT Y2 Y/Y2 TRANSFORMER W W2 W1 C C PROGRAMMABLE THERMOSTAT ONLY Figure 8: Typical Field Control Wiring Diagram 2 Stage Thermostat Figure 9: Typical Field Power Wiring Diagram Table 5: Electrical Data 2 OD Fan Supply Max Fuse / Compressors 1

Summary of the content on the page No. 10

288429-YIM-A-0307 Table 5: Electrical Data (Continued) 2 OD Fan Supply Max Fuse / Compressors 1 3 Motors Blower Electric Heat Option Size MCA Breaker (each) Model Volt (each) Motor (Tons) (Amps) Size (Amps) RLA LRA MCC FLA FLA Model kW Stages Amps None - - - 29 35 2NH04500506 3.8/5 1 18.1/20.8 51.5/55 60/60 208/230-1-60 16.6 96 26 1.4 6.8 2NH04500706 5.6/7.5 2 27.1/31.3 62.8/68 70/70 2NP04501006 7.5/10 2 36.1/41.7 74.1/81 80/90 2NP04501506 11.3/15 2 54.2/62.5 96.7/107.1 100/110 042 DEX None -

Summary of the content on the page No. 11

288429-YIM-A-0307 Table 6: Physical Data (Continued) Models Component DEX024 DEX030 DEX036 DEX042 DEX048 DEY060 Nominal Tonnage 2.0 2.5 3.0 3.5 4.0 5.0 DIMENSIONS (inches) Length 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 49 1/8 Width 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 47 1/4 Height 33 1/2 33 1/2 33 1/2 41 1/2 41 1/2 41 1/2 OPERATING WT. (lbs.) 355 390 400 410 440 460 COMPRESSORS Type Scroll 2-spd Scroll 2-spd Scroll 2-spd Scroll 2-spd Scroll 2-spd Scroll 2-spd Quantity 1 1 1 1 1 1 CONDENSER COIL DATA

Summary of the content on the page No. 12

288429-YIM-A-0307 Procedures which risk oil leakage include, but are not limited to, Phasing compressor replacement, repairing refrigerant leaks, replacing Three-phase, scroll compressors operate in only one direction. refrigerant components such as filter drier, pressure switch, If the scroll is drawing low amperage, has similar suction and metering device or coil. discharge pressures, or is producing a high noise level, the Units are shipped with compressor mountings which are factory s

Summary of the content on the page No. 13

288429-YIM-A-0307 Table 7: Side Duct Application (Continued) External Static Pressure (Inch Water Gauge) Size Thermostat Speed Model Mode CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (Tons) Input Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 1050 184 216 248 280 313 346 380 414 449 Y1 COOL-B 920 139 166 195 224 255 286 319 352 386 Low Y1 COOL-C 980 159 188 218 249 281 313 346 379 414 Y1 COOL-D 1120 211 245 279 313 348 382 417 452 486 Cool Y1+Y2 COOL-A 1600 448 500 551 600 647 69

Summary of the content on the page No. 14

288429-YIM-A-0307 Table 8: Bottom Duct Application (Continued) External Static Pressure (Inch Water Gauge) Size Thermostat Speed Model Mode CFM 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 (Tons) Input Tap Watts Watts Watts Watts Watts Watts Watts Watts Watts Y1 COOL-A 920 139 166 195 224 255 286 319 352 386 Y1 COOL-B 790 100 124 149 176 205 235 266 299 333 Low Y1 COOL-C 850 117 143 170 198 227 257 289 322 356 Y1 COOL-D 980 159 188 218 249 281 313 346 379 414 Cool Y1+Y2 COOL-A 1400 338 383 426 468 509 54

Summary of the content on the page No. 15

288429-YIM-A-0307 Table 9: Additional Static Resistance (Continued) Size 1 Model CFM Wet Indoor Coil Economizer Filter/Frame Kit Electric Heat (Tons) 1100 0.03 0.01 0.03 0.05 1200 0.04 0.02 0.03 0.06 042 1300 0.04 0.03 0.03 0.07 DEX (3.5) 1400 0.04 0.04 0.03 0.08 1500 0.05 0.05 0.04 0.09 1600 0.06 0.06 0.05 0.10 1100 0.03 0.01 0.03 0.05 1200 0.04 0.02 0.03 0.06 1300 0.04 0.03 0.03 0.07 1400 0.04 0.04 0.03 0.08 048 1500 0.04 0.05 0.04 0.09 DEX (4.0) 1600 0.04 0.06 0.05 0.10 1700 0.05 0.07 0.05 0.

Summary of the content on the page No. 16

288429-YIM-A-0307 Table 13: DEX024 Superheat Charging Superheat at Compressor Suction (°F), Airflow = 800 CFM Outdoor Temp Indoor Wet Bulb Temp (°F) (°F) 55 57 59 61 63 65 67 69 71 73 75 65 23.4 24.2 25.0 25.8 26.7 27.5 28.3 28.1 27.9 27.8 27.7 70 20.8 21.6 22.4 23.2 24.0 24.8 25.6 25.7 25.9 25.9 26.0 75 18.3 19.1 19.8 20.6 21.3 22.1 22.8 23.3 23.8 24.1 24.3 80 15.8 16.5 17.2 17.9 18.6 19.3 20.1 20.9 21.8 22.2 22.6 85 13.2 13.9 14.6 15.3 15.9 16.6 17.3 18.5 19.7 20.3 20.9 90 12.9 13.5 14.0

Summary of the content on the page No. 17

288429-YIM-A-0307 Table 17: DEX048 Superheat Charging Superheat at Compressor Suction (°F), Airflow = 1600 CFM Outdoor Temp Indoor Wet Bulb Temp (°F) (°F) 55 57 59 61 63 65 67 69 71 73 75 65 10.1 10.0 9.9 9.8 9.8 9.7 9.6 9.6 9.7 9.7 9.7 70 9.9 9.8 9.7 9.7 9.6 9.5 9.5 9.5 9.6 9.6 9.6 75 9.7 9.6 9.5 9.5 9.4 9.4 9.3 9.4 9.5 9.5 9.5 80 9.5 9.4 9.4 9.3 9.3 9.2 9.2 9.3 9.4 9.4 9.5 85 9.2 9.2 9.2 9.1 9.1 9.0 9.0 9.1 9.2 9.3 9.4 90 8.8 8.9 8.9 8.9 9.0 9.0 9.1 9.2 9.4 9.5 9.5 95 8.4 8.5 8.6 8.7 8.9 9.0 9

Summary of the content on the page No. 18

288429-YIM-A-0307 Fan Only CFM: operate the blower at high speed and energizes the compressor solenoid to close the bypass ports so that the When the connection is made from “R” to “G”, the fan only compressor operates at full capacity. If the outdoor fan mode is activated. In this mode, the blower will deliver 75% of motor has an ECM controller, the 24 volts at "Y2" signals the cooling system CFM. This connection is factory set from the the motor to operate at high speed. manufacturer a

Summary of the content on the page No. 19

288429-YIM-A-0307 Table 20: Thermostat Signals (Single Phase Units) Signal State Board Function ON BLOWER INSTANT ON AT 75% RATED AIRFLOW G OFF BLOWER INSTANT OFF BLOWER INSTANT ON ON COMPRESSOR AND OUTDOOR FAN INSTANT ON (AFTER ANTI-SHORT CYCLE DELAY) G & Y1 SYSTEM OPERATES IN FIRST STAGE COOLING COMPRESSOR AND OUTDOOR FAN INSTANT OFF OFF BLOWER OFF DELAY DETERMINED BY “DELAY” JUMPER SETTING BLOWER INSTANT ON ON COMPRESSOR AND OUTDOOR FAN INSTANT ON (AFTER ANTI-SHORT CYCLE DELAY) G, Y1 & Y2 SYS

Summary of the content on the page No. 20

288429-YIM-A-0307 Maintenance Normal Maintenance Exercise care when cleaning the coil so that the coil fins are not damaged. Do not permit the hot condenser air discharge to be obstructed by overhanging structures or shrubs. Prior to any of the following maintenance procedures, shut off all power to the unit, to avoid personal injury. Troubleshooting Periodic maintenance consists of changing or cleaning filters and general cleaning of the outdoor coil. FILTERS - Inspect once a month. Replace


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21