HP (Hewlett-Packard) Hewlett-PackardB110I user manual

User manual for the device HP (Hewlett-Packard) Hewlett-PackardB110I

Device: HP (Hewlett-Packard) Hewlett-PackardB110I
Category: Computer Hardware
Manufacturer: HP (Hewlett-Packard)
Size: 0.4 MB
Added : 1/30/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for HP (Hewlett-Packard) Hewlett-PackardB110I. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with HP (Hewlett-Packard) Hewlett-PackardB110I.

For your convenience

If looking through the HP (Hewlett-Packard) Hewlett-PackardB110I user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual HP (Hewlett-Packard) Hewlett-PackardB110I on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual HP (Hewlett-Packard) Hewlett-PackardB110I to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
HP (Hewlett-Packard) Hewlett-PackardB110I User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual HP (Hewlett-Packard) Hewlett-PackardB110I but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to HP (Hewlett-Packard) Hewlett-PackardB110I. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


HP Smart Array B110i SATA RAID Controller
User Guide



Part Number 531480-003
March 2010 (Third Edition)

Summary of the content on the page No. 2

© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of M

Summary of the content on the page No. 3

Contents Enabling and configuring the controller ........................................................................................... 5 Enabling the controller and setting the boot order ............................................................................................ 5 HP ProLiant 100 Series servers ............................................................................................................ 5 HP ProLiant 300 Series servers ................................

Summary of the content on the page No. 4

Index ......................................................................................................................................... 26

Summary of the content on the page No. 5

Enabling and configuring the controller Enabling the controller and setting the boot order The HP Smart Array B110i SATA RAID Controller is not enabled by default and must be enabled in RBSU. For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation). HP ProLiant 100 Series servers To enable the controller and set boot order: 1. Power up the server. 2. When prompted during

Summary of the content on the page No. 6

Configuring an array The HP Smart Array B110i SATA RAID Controller supports SATA drives only. For the most efficient use of drive space, all drives within an array should have approximately the same capacity. Each configuration utility treats every physical drive in an array as if it has the same capacity as the smallest drive in the array. Any excess capacity of a particular drive cannot be used in the array. Therefore, the capacity is unavailable for data storage. The more physical dri

Summary of the content on the page No. 7

6. Press the F8 key to confirm the settings and save the new configuration. After several seconds, the Configuration Saved screen appears. 7. Press the Enter key to continue. Repeat this procedure to create additional logical drives. Array Configuration Utility ACU is a browser-based utility with the following features: • Runs as a local application or remote service • Supports assignment of online spares • Suggests the optimum configuration for an unconfigured system • Provides di

Summary of the content on the page No. 8

IMPORTANT: The license key is stored on the hard drive. If no hard drives are installed, the license key cannot be installed. Before installing the license key, be sure that hard drives are installed. For more information on installing hard drives, see the server user guide. To obtain the license key, see the entitlement certificate included with the HP Hot Plug Advanced Pack. Depending on the method of delivery, the certificate is provided either in a sealed envelope or in an ema

Summary of the content on the page No. 9

The ORCA main menu appears. 4. Select Manage License Keys. IMPORTANT: If no hard drives are installed, then this option does not appear. 5. Under the License Key menu, select Add License Key. 6. Enter the license key in the space provided. ORCA issues a notification after the license key activates successfully. Installing a license key with ACU To install a license key: 1. Power down the server, if necessary. 2. Power up the server. Enabling and configuring the controll

Summary of the content on the page No. 10

3. Open ACU. 4. Select a controller from the Controller/Device menu. The System Status, Systems And Devices, and Available Tasks panels appear. 5. In the Available Tasks panel, click Manage License Keys. IMPORTANT: If no hard drives are installed, then this option does not appear. Specific license key tasks appear. A complete list of existing license keys also appears. 6. Click Add License Key. 7. Enter the license key number. 8. Click Save. Enabling and configuring the con

Summary of the content on the page No. 11

Installing device drivers and Management Agents Installing device drivers IMPORTANT: Enable the HP Smart Array B110i SATA RAID Controller before installing device drivers. For more information see "Enabling the controller and setting the boot order (on page 5)." A device driver is required for the operating system to communicate with the disk drive controller. For more information on supported operating systems, see the HP Smart Array B110i SATA RAID Controller product page on

Summary of the content on the page No. 12

You can update the Management Agents by using the latest versions of the agents provided on the SmartStart CD or the Easy Set-up CD. The procedure is provided with the agents. To download the latest versions of the CDs, see the HP website: • SmartStart CD (http://h18013.www1.hp.com/products/servers/management/smartstart/documentation.html?jumpi d=hpr_R1002_USEN). • Easy Set-up CD (http://h18013.www1.hp.com/products/servers/management/remotemgmt/easy_setup_cd/index.h tml?jumpid=reg_R1002_

Summary of the content on the page No. 13

Replacing, moving, or adding hard drives Recognizing hard drive failure CAUTION: Sometimes, a drive that has previously been failed by the controller may seem to be operational after the system is power-cycled or (for a hot-pluggable drive) after the drive has been removed and reinserted. However, continued use of such marginal drives may eventually result in data loss. Replace the marginal drive as soon as possible. The HP Smart Array B110i SATA RAID Controller supports drive L

Summary of the content on the page No. 14

• RAID 0 configurations cannot tolerate drive failure. If any physical drive in the array fails, all RAID 0 logical drives in the same array also fail. • RAID 1 configurations can tolerate one drive failure. If one physical drive in a RAID 1 configuration fails, the RAID volume is still intact as a degraded RAID 1. • RAID 1+0 configurations can tolerate up to two drive failures as long as no failed drives are mirrored to one another. A RAID 1+0 configuration of four drives consists of tw

Summary of the content on the page No. 15

Replacing hard drives If you are replacing a drive in a fault-tolerant configuration while the system is powered down, a POST message appears when the system is powered up. When this message appears, press the F1 key to enable automatic data recovery. If you do not enable automatic data recovery, the logical volume remains in a ready-to-recover condition, and the same POST message appears when the system is restarted. In RAID 1 configurations, you can replace one failed drive. In RAID 1

Summary of the content on the page No. 16

• The brand, model, and age of the drives • The amount of unused capacity on the drives Allow approximately 15 minutes per gigabyte for the rebuild process to complete. System performance is affected during the rebuild, and the system is unprotected against further drive failure until the rebuild has finished. Therefore, replace drives during periods of low activity, when possible. When automatic data recovery has finished, the state of the logical volume is updated in ACU/ACU-CLI /age

Summary of the content on the page No. 17

You might be able to enable a recently failed drive temporarily by cycling the server power. To cycle the server power: 1. Power down the server. 2. Remove the replacement physical drive (the one undergoing a rebuild), and then reinstall the drive that it is replacing. 3. Power up the server. If the newly failed drive is operational, do the following: 1. Back up any unsaved data. 2. Remove the original drive that was being replaced, and then reinsert the replacement physical drive.

Summary of the content on the page No. 18

2. Power down the system. 3. Move the drives. 4. Power up the system. 5. Observe the POST messages: o If a 1785 POST message appears, the drive array did not configure properly. Continue with step 6. o If a 1724 or 1727 POST message appears, drive positions were changed successfully and the configuration was updated. Continue with step 7. 6. If the array did not configure properly, do the following: a. Power down the system immediately to prevent data loss. b. Return the drives to th

Summary of the content on the page No. 19

Migrating hard drives to an optional Smart Array controller Installing an optional Smart Array controller To install the component: 1. Power down the server. 2. Remove the access panel. 3. Remove components and cables as needed. 4. Install the Smart Array controller. For more information, see the server user guide or the documentation that ships with the option. 5. Install components and cables removed previously. 6. Install the access panel. 7. Power up the server. 8. Migrate hard

Summary of the content on the page No. 20

To install the driver from the Easy Set-up CD: 1. From the System Support Software menu, select the current operating system. 2. Select Driver – storage controller. 3. Download the HP ProLiant Smart Array SAS/SATA Controller Driver package. 4. To install the driver, run the Smart Array Controller package. When the driver is installed, complete the migration procedure. Completing the migration to an optional Smart Array controller—Microsoft® Windows® To complete the migration to the S


Alternative user manuals
# User manual Category Download
1 HP (Hewlett-Packard) AMD Geode GX466 User manual Computer Hardware 5
2 HP (Hewlett-Packard) gnu source-level debugger 5992-4701 User manual Computer Hardware 0
3 HP (Hewlett-Packard) Hewlett-PackardKayak PC Workstation User manual Computer Hardware 2
4 HP (Hewlett-Packard) 744 User manual Computer Hardware 3
5 HP (Hewlett-Packard) E1367A User manual Computer Hardware 0
6 HP (Hewlett-Packard) AMD Geode E2047551001R User manual Computer Hardware 0
7 HP (Hewlett-Packard) Hewlett-PackardXA User manual Computer Hardware 0
8 HP (Hewlett-Packard) GS1280 User manual Computer Hardware 0
9 HP (Hewlett-Packard) Hewlett Packard Hp Hp Tesla K20 Graphic Card C7S14A User manual Computer Hardware 0
10 HP (Hewlett-Packard) HP NC364T Quad Port Gigabit Server Adapter 435508-B21 User manual Computer Hardware 4
11 HP (Hewlett-Packard) Hewlett-PackardA5992-90100 User manual Computer Hardware 0
12 HP (Hewlett-Packard) Hewlett-PackardD300 DT User manual Computer Hardware 7
13 HP (Hewlett-Packard) E1366A User manual Computer Hardware 3
14 HP (Hewlett-Packard) Hewlett-PackardD500 DT User manual Computer Hardware 7
15 HP (Hewlett-Packard) HP blade PC bc1000 User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1