York PREDATOR 150 user manual

User manual for the device York PREDATOR 150

Device: York PREDATOR 150
Category: Air Conditioner
Manufacturer: York
Size: 1.53 MB
Added : 2/7/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York PREDATOR 150. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York PREDATOR 150.

For your convenience

If looking through the York PREDATOR 150 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York PREDATOR 150 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York PREDATOR 150 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York PREDATOR 150 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York PREDATOR 150 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York PREDATOR 150. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


INSTALLATION
MANUAL
SINGLE PACKAGE AIR CONDITIONERS AND
CONTENTS
SINGLE PACKAGE ELECTRIC UNITS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
DM090, 120 and 150
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . .5
7-1/2 TO 12-1/2 TON
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
(380V, 3 Phase, 60 HZ)
REFERENCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
APPROVALS. . . . . . . . .

Summary of the content on the page No. 2

035-17311-002-A-0803 TABLE OF CONTENTS METHOD ONE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 METHOD TWO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . 5 SUPPLY AIR DRIVE ADJUSTMENT . . . . . . . . . . . . . . . . . 32 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

035-17311-002-A-0803 LIST OF FIGURES Fig. # Pg.# Fig. # Pg.# 1 UNIT SHIPPING BRACKET . . . . . . . . . . . . . . . . . . . . 10 13 SIDE PANELS WITH HOLE PLUGS . . . . . . . . . . . . . 16 2 CONDENSER COVERING . . . . . . . . . . . . . . . . . . . . 10 14 RETURN DOWNFLOW PLENUM WITH PANEL . . . 16 3 COMPRESSOR SECTION . . . . . . . . . . . . . . . . . . . . . 10 15 DISCHARGE PANEL IN PLACE . . . . . . . . . . . . . . . . 16 ® 4 PREDATOR COMPONENT LOCATION . . . . . . . . . 11 16 CONDENSATE DRA

Summary of the content on the page No. 4

035-17311-002-A-0803 LIST OF TABLES Tbl.# Pg.# Tbl.# Pg.# 1 UNIT VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . 11 20 10 TON OPTIONAL MOTOR DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . 26 2 UNIT TEMPERATURE LIMITATIONS . . . . . . . . . . . . 11 21 12-1/2 TON STANDARD MOTOR DOWN SHOT 3 UNIT WEIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . 27 4 6 POINT LOAD WEIGHT . . . . . . . . . .

Summary of the content on the page No. 5

035-17311-002-A-0803 GENERAL REFERENCE Additional information is available in the following reference  ® YORK Predator units are single package air conditioners forms: designed for outdoor installation on a rooftop or slab and for non-residential use. These units can be equipped with factory  General Installation - DM090 - 150, 035-17311-002 or field installed electric heaters for heating applications.  Pre-start & Post-start Check List - 035-18466-000 These units are completely assembled on

Summary of the content on the page No. 6

035-17311-002-A-0803 NOMENCLATURE 6½ - 12½ Ton Predator Model Number Nomenclature D M 090 C00 A 3 A AA 3 Product Generation Product Category 3 = Third Generation D = Air Cond., Single Package Product Identifier Voltage Installation Options Additional Options M = R-22 Standard Efficiency A = No Options Installed (See Next Page) 3 = 380-3-60 B = Option 1 C = Option 2 D = Options 1 & 2 Nominal Cooling Capacity - MBH E = Option 3 F = Option 4 090 = 7-½ Ton G = Options 1 & 3 120 = 10 Ton H = Options

Summary of the content on the page No. 7

035-17311-002-A-0803 NOMENCLATURE, ADDITONAL OPTIONS: AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Switch AE Phase Monitor & Coil Guard AF Phase Monitor & Dirty Filter Switch AG Coil Guard & Dirty Filter Switch AH Phase Monitor, Coil Guard, & Dirty Filter Switch CA CPC Controller with Dirty Filter Switch & Air Proving Switch CB CPC Controller, DFS, APS & Phase Monitor CC CPC Controller, DFS, APS & Coil Guard CD CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CE CPC Controller, DF

Summary of the content on the page No. 8

035-17311-002-A-0803 HN Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils HP Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor HQ Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard HR Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard JA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch JB Johnson UNT Controller, DFS, APS & Phase Monito

Summary of the content on the page No. 9

035-17311-002-A-0803 TE Technicoat Condenser Coil, Phase Monitor, & Coil Guard TF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch TG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch TH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TJ Technicoat Evaporator Coil TK Technicoat Evaporator Coil & Phase Monitor TL Technicoat Evaporator Coil & Coil Guard TM Technicoat Evaporator Coil & Dirty Filter Switch TN Technicoat Evaporator Coil, Phase Mon

Summary of the content on the page No. 10

035-17311-002-A-0803 INSTALLATION INSTALLATION SAFETY INFORMATION Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cool- ing unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference. 1. Install this furnace only in a location and position as specified on Page 11 of these instructions. 2. This equipment is not to be used for temporary hea

Summary of the content on the page No. 11

035-17311-002-A-0803 Simplicity™ Control board w/screw connector Disconnectlocation for T-stat wiring and (optionaldisconnectswitch) Filteraccess(2”throw-away) Terminalblockfor network connection Filterdrier(solid hi-voltageconnection core) Condenser Secondmodelname- section plateinsidehinged accesspanel Belt-drive blowermotor Slideout motor & blower assembly for easy access Dualstage adjustment & coolingfor service max.comfort Compressor#2 Compressor#1access(high- access(high- efficiencycompres

Summary of the content on the page No. 12

035-17311-002-A-0803 TABLE 4: 6 POINT LOAD WEIGHT * Location (lbs.) Model A BCD E F Before lifting, make sure the unit weight is distrib- DM090 158 142 128 187 207 230 uted equally on the rigging cables so it will lift evenly. DM120 168 151 136 198 219 244 DM150 180 161 145 212 235 262 Units may be moved or lifted with a forklift. Slotted openings in the base rails are provided for this purpose. *. Weights include largest gas heat option. LENGTH OF FORKS MUST BE A MINIMUM OF 60 TABLE 5: 4 PO

Summary of the content on the page No. 13

035-17311-002-A-0803 Do not permit overhanging structures or shrubs to obstruct condenser air discharge outlet, combustion air inlet or vent outlets.    " "       !     & '     )    ) *    *    "  & '  !  " !    ) *    "    $      %  & '   (                 ) *                           "    " #     " #                 !   " # #  

Summary of the content on the page No. 14

035-17311-002-A-0803 . 32-11/16 6-13/16 6-13/16 6-13/16 Supply Air Return Air 24 27-1/2 LEFT 21 18 21-3/16 19-3/16 17-3/16 12-15/16 7-1/8 FRONT 14- 23/32 Bottom Bottom Gas Bottom Power, Control Supply Entry Condensate 16-3/8 and Entry Convenience 18-1/16 Outlet Wiring Entries 19-5/8 63-1/2 FIGURE 9 - BOTTOM DUCT OPENINGS (FROM ABOVE) "   " !    &  ( 3    (     " !    ( / /  )   "   " ! &   % 1  &          2   (  "   " " #      &   

Summary of the content on the page No. 15

035-17311-002-A-0803 DUCTWORK DUCT COVERS Ductwork should be designed and sized according to the Units are shipped with the side duct openings covered and a methods in Manual D of the Air Conditioning Contractors of covering over the bottom of the unit. For bottom duct applica- America (ACCA) or as recommended by any other recog- tion, no duct cover changes are necessary. For side duct nized authority such as ASHRAE or SMACNA. application, remove the side duct covers and install over the bottom

Summary of the content on the page No. 16

035-17311-002-A-0803 CONDENSATE DRAIN The side condensate drain is reversible and maybe re-ori- ented to the rear of the cabinet to facilitate condensate pip- When fastening ductwork to side duct flanges on ing. A condensate drain connection is available through the unit, insert screws through duct flanges only. DO base pan for piping inside the roof curb. Trap the connection NOT insert screws through casing. Outdoor duct- per Figure 16. The trap and drain lines should be protected from freezing

Summary of the content on the page No. 17

035-17311-002-A-0803 THERMOSTAT WIRING The thermostat should be located on an inside wall approxi- mately 56 inches above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or Avoid damage to internal components if drilling appliances. Follow the manufacturer's instructions enclosed holes for disconnect mounting. with thermostat for general installation procedure. Seven (7) color-coded, insulated wires should be used to connect the NOTE: Since not all

Summary of the content on the page No. 18

035-17311-002-A-0803 "  9  8       8 0    6 0     8 0      0 &    "  9 4 " 4 " 4  4  - " - " -  -  . .    !  +       ,   ; " ; ;     ; !  "        8           !   "   !  0   6    "     %    %  / 3     <     1                "    !  =   %  ( 2     ( < <    > 5             "    2     / $  2    

Summary of the content on the page No. 19

035-17311-002-A-0803   8 0       7    "     4    0    . 6   6 & &  0     0       6 .  9   & 9    & -   6 & &  4 FIGURE 19 - FIELD WIRING DISCONNECT TABLE 8: ELECTRICAL DATA - DM090 (7-1/2 TON) WITHOUT POWER CONVENIENCE OUTLET Min. MCA Max Max Fuse* Supply Pwr Pwr OD Fan Circuit w/Power Fuse* Size Compressors Blower Exh Conv Motors Electric Heater Actual Heater Ampacity Exhaust Size w/Power Voltage Motor FLA Motor Outlet

Summary of the content on the page No. 20

035-17311-002-A-0803 TABLE 10: ELECTRICAL DATA - DM120 (10 TON) WITHOUT POWER CONVENIENCE OUTLET MCA Max Max Fuse* Supply Pwr Pwr Min. Circuit OD Fan w/Power Fuse* Size Compressors Blower Motor Exh Conv Ampacity Motors Electric Heater Actual Heater Exhaust Size w/Power Voltage FLA Motor Outlet (Amps) Model No. KW Amps (Amps) (Amps) Exhaust RLA LRA FLA 2 3 2323 2 3 2 3 FLA FLA ea. ea. ea. HP HP HP HP HP HP HP HP HP HP None -- -- 33.2 34.4 35.4 36.6 40 45 45 45 2TP04521850 11.3 17.2 33


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21