York PREDATOR DM150 user manual

User manual for the device York PREDATOR DM150

Device: York PREDATOR DM150
Category: Air Conditioner
Manufacturer: York
Size: 3.69 MB
Added : 2/7/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York PREDATOR DM150. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York PREDATOR DM150.

For your convenience

If looking through the York PREDATOR DM150 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York PREDATOR DM150 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York PREDATOR DM150 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York PREDATOR DM150 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York PREDATOR DM150 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York PREDATOR DM150. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

036-21044-003-A-0304
 
TECHNICAL
TECHNICAL
GUIDE 50Hz
GUIDE 50Hz
TM
DESCRIPTION
® ®
YORK Predator units are convertible single packages with a
common footprint cabinet and common roof curb for all 7-1/2
through 12-1/2 ton models. All units have two compressors with
independent refrigeration circuits. The units were designed for
light commercial applications and can be easily installed on a roof
curb, slab, roof jack, or frame.
SINGLE PACKAGE AIR CONDITIONERS AND
®
All Predator units ar

Summary of the content on the page No. 2

036-21044-003-A-0304 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # Pg. # 16 BLOWER PERFORMANCE 7-1/2 TON OPTIONAL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 MOTOR - SIDE DUCT (METRIC) . . . . . . . . . . . . . . . . 22 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . 5 17 BLOWER PERFORMANCE 10 TON STANDARD MOTOR - SIDE DUCT (IMPERIAL) . . . . . . . . . . . . . . . 22 FIELD INSTALLED ACCESSORIES . . . . .

Summary of the content on the page No. 3

036-21044-003-A-0304 ™ Control Board w/ Screw Connector for T-stat Filter Access Terminal Block Disconnect Location Filter-Drier (Solid Core) Wiring and Network Connection (2” Filters) for Hi-Voltage (Optional Disconnect Switch) Connection Condenser Section Second model Slide-out motor nameplate inside and blower hinged access assembly for panel easy adjustment and service Dual stage cooling for Belt-Drive maximum Blower Motor comfort Power Ventor Motor Compressor #2 Access

Summary of the content on the page No. 4

036-21044-003-A-0304 ® • Balanced Heating – The Predator offers “Ultimate • Nuisance Trip Protection and Strikes - To prevent st nd Heating Comfort” with a balance between 1 and 2 nuisance trouble calls, the control board uses a st ® stage gas heating. The 1 stage of a gas heat Predator “three times, you’re out” philosophy. The high and unit provides 60% of the heating capacity. Balanced low-pressure switches and the freezestats must trip heating allows the unit to better maintain desired t

Summary of the content on the page No. 5

036-21044-003-A-0304 • Wide Range of Indoor Airflows – All indoor fan motors • Alternate Indoor Blower Motor - For applications with are belt-drive type providing maximum flexibility to han- high static restrictions, units are offered with optional dle most airflow requirements. For high static applica- indoor motors that provide higher static output and/or tions, factory installed alternate indoor fan motors are higher airflow, depending upon the installer’s needs. available. With the opti

Summary of the content on the page No. 6

036-21044-003-A-0304 • CPC BAS Control - The Computer Process Controls • Motorized Outdoor Air Damper - The motorized out- Model 810-3060 ARTC Advanced Rooftop building auto- door air damper includes a slide-in/plug-in damper mation system controller is factory installed. Includes assembly with an outdoor air hood and filters. The out- supply air sensor, return air sensor, dirty filter indicator door air dampers open to the preset position when the switch, and air proving switch. indoor fan mo

Summary of the content on the page No. 7

036-21044-003-A-0304 • Low Limit / Compressor Lockout Kit in 8” (203 mm) and 14” (356 mm) heights. For applica- tions with security concerns, burglar bars are available 1. Compressor Lockout (CLO): To prevent mechani- for the duct openings of the roof curbs. cal (compressorized) operation of the unit during cold outdoor conditions where there is a risk of • Roof Curb Transition - Single Piece Adapter (10” (254 returning liquid refrigerant back to the compressors. mm) High) - Roof curbs for tr

Summary of the content on the page No. 8

036-21044-003-A-0304 NOMENCLATURE 7½ - 12½ Ton Predator Model Number Nomenclature D M 090 N10 AA 3 A 7 A Product Generation Product Category 3 = Third Generation D = Air Cond., Single Package Voltage Installation Options Additional Options Product Identifier A = No Options Installed 7 = 380/415-3-50 (See Next Page) B = Option 1 M = R-22 Standard Efficiency C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 Nominal Cooling Capacity - MBH J = Options 1, 2

Summary of the content on the page No. 9

036-21044-003-A-0304 NOMENCLATURE ADDITIONAL OPTIONS:ì AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Switch AE Phase Monitor & Coil Guard AF Phase Monitor & Dirty Filter Switch AG Coil Guard & Dirty Filter Switch AH Phase Monitor, Coil Guard, & Dirty Filter Switch CA CPC Controller with Dirty Filter Switch & Air Proving Switch CB CPC Controller, DFS, APS & Phase Monitor CC CPC Controller, DFS, APS & Coil Guard CD CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CE CPC Controller, D

Summary of the content on the page No. 10

036-21044-003-A-0304 HP Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor HQ Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard HR Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard JA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch JB Johnson UNT Controller, DFS, APS & Phase Monitor JC Johnson UNT Controller, DFS, APS & Coil Guard JD Johnson UNT Controlle

Summary of the content on the page No. 11

036-21044-003-A-0304 TG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch TH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TJ Technicoat Evaporator Coil TK Technicoat Evaporator Coil & Phase Monitor TL Technicoat Evaporator Coil & Coil Guard TM Technicoat Evaporator Coil & Dirty Filter Switch TN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard TP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch TQ Technicoat Evaporator Coil, Coil Gu

Summary of the content on the page No. 12

036-21044-003-A-0304 TABLE 1: PHYSICAL DATA Models Component 090 120 150 Blower, Centrifugal 15 x 15 15 x 15 15 x 15 Dia. X Wd. in. (381 x 381) (381 x 381) (381 x 381) (Dia. X Wd. mm.) Evaporator Blower Motor, Standard - HP (kW) 1-1/2 (1.1) 2 (1.5) 4 (3) Motor, Optional - HP (kW) 2 (1.5) 4 (3) N/A Rows 2 3 4 Fins per 2.54 cm (1 in.) 15 15 15 Evaporator Coil Height - in. (mm.) 32 (810) 40 (1020) 40 (1020) 2 2 10.6 (0.98) 13.2 (1.23) 13.2 (1.23) Face Area - ft. (m ) Propeller Dia. - in. (mm.) ea

Summary of the content on the page No. 13

036-21044-003-A-0304 TABLE 2: CAPACITY RATINGS IMPERIAL Cooling Capacity Nominal Gas Heat Capacity Model Electric Sound (80 / 67-95°F) Heat Gas Line Rating Input Output Temp Capacity Size (dB) (MBH) (MBH) Rise (°F) 1 Cooling Cap. (MBH) Options MBH EER (in. OD) (kW) 7, 14, DM 89 9.00 87 - - - - 18, 27 090 10 - - - - 120 96 15-45 3/4 15 - - - - 180 144 30-60 3/4 14, 18, DM 116 9.0 85 - - - - 27, 41 120 15 - - - - 180 144 20-50 3/4 14, 18, DM 138 9.0 84 - - - - 27, 41 150 15 - - - - 180 144 10-

Summary of the content on the page No. 14

036-21044-003-A-0304 TABLE 4: COOLING CAPACITY 7-1/2 TON UNIT - IMPERIAL Air On Temperature of Air on Condenser Coil 85°F Temperature of Air on Condenser Coil 95°F Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (MBH) Sensible Capacity (MBH) WB 1 2 1 2 CFM Return Dry Bulb (°F) Return Dry Bulb (°F) Cap. Input Cap. Input (°F) (MBH) (kW) 86 83 80 77 74 71 68 (MBH) (kW) 86 83 80 77 74 71 68 72 104 8.6 60 54 47 41 34 - - 98 9.2 57 50 44 37 31 - - 67 96 8.4 74 68 61 55 48 42 35 90 9.0 71 64 58 51

Summary of the content on the page No. 15

036-21044-003-A-0304 TABLE 5: COOLING CAPACITY 26.4 KW UNIT - METRIC Air On Temperature of Air on Condenser Coil 29°C Temperature of Air on Condenser Coil 35°C Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (kW) Sensible Capacity (kW) WB 3 1 2 1 2 Return Dry Bulb (°F) Return Dry Bulb (°C) m /s Cap. Input Cap. Input (°C) (kW) (kW) 30 28 27 25 23 22 20 (kW) (kW) 30 28 27 25 23 22 20 22 31 8.6 18 16 14 12 10 - - 29 9.2 17 15 13 11 9 - - 19 28 8.4 22 20 18 16 14 12 10 26 9.0 21 19 17 15 13 11

Summary of the content on the page No. 16

036-21044-003-A-0304 TABLE 6: COOLING CAPACITY 10 TON UNIT - IMPERIAL Air On Temperature of Air on Condenser Coil 85°F Temperature of Air on Condenser Coil 95°F Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (MBH) Sensible Capacity (MBH) WB 1 2 1 2 CFM Return Dry Bulb (°F) Return Dry Bulb (°F) Cap. Input Cap. Input (°F) (MBH) (kW) 86 83 80 77 74 71 68 (MBH) (kW) 86 83 80 77 74 71 68 72 148 11.2 82 73 65 56 48 - - 137 12.0 79 71 62 54 45 - - 67 134 10.8 102 94 85 77 68 60 51 124 11.6 98 90

Summary of the content on the page No. 17

036-21044-003-A-0304 TABLE 7: COOLING CAPACITY 35.1 KW UNIT - METRIC Air On Temperature of Air on Condenser Coil 29°C Temperature of Air on Condenser Coil 35°C Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (kW) Sensible Capacity (kW) WB 3 1 2 1 2 Return Dry Bulb (°C) Return Dry Bulb (°C) m /s Cap. Input Cap. Input (°C) (kW) (kW) 30 28 27 25 23 22 20 (kW) (kW) 30 28 27 25 23 22 20 22 43 11.2 24 22 19 16 14 - - 40 12.0 23 21 18 16 13 - - 19 39 10.8 30 28 25 22 20 17 15 36 11.6 29 26 24 21 1

Summary of the content on the page No. 18

036-21044-003-A-0304 TABLE 8: COOLING CAPACITY 12-1/2 TON UNIT - IMPERIAL Air On Temperature of Air on Condenser Coil 85°F Temperature of Air on Condenser Coil 95°F Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (MBH) Sensible Capacity (MBH) WB 1 2 1 2 CFM Return Dry Bulb (°F) Return Dry Bulb (°F) Cap. Input Cap. Input (°F) (MBH) (kW) 86 83 80 77 74 71 68 (MBH) (kW) 86 83 80 77 74 71 68 72 150 11.8 90 80 69 58 47 - - 143 13.0 88 78 67 56 45 - - 67 140 11.5 115 104 94 83 72 61 51 132 12.6 1

Summary of the content on the page No. 19

036-21044-003-A-0304 TABLE 9: COOLING CAPACITY 43.9 KW UNIT - METRIC Air On Temperature of Air on Condenser Coil 29°C Temperature of Air on Condenser Coil 35°C Evap. Coil 1 1 Tot. Tot. Tot. Tot. Sensible Capacity (kW) Sensible Capacity (kW) WB 3 1 2 1 2 Return Dry Bulb (°C) Return Dry Bulb (°C) m /s Cap. Input Cap. Input (°C) (kW) (kW) 30 28 27 25 23 22 20 (kW) (kW) 30 28 27 25 23 22 20 22 44 11.8 26 23 20 17 14 - - 42 13.0 26 23 20 16 13 - - 19 41 11.5 34 31 27 24 21 18 15 39 12.6 33 30 26 23 2

Summary of the content on the page No. 20

036-21044-003-A-0304 TABLE 10: ELECTRICAL DATA 7-1/2 TON MCA Max Fuse Size OD Min. Circuit 2 Supply Blower Pwr Exh w/Power w/Power Max Fuse Compressors Fan Ampacity Motor FLA Motor Exhaust Exhaust Electric Size (Amps) Motors (Amps) Actual Heater (Amps) (Amps) 1 Heater Voltage kW Amps Model No. 1.5 HP 2 HP 1.5 HP 2 HP 1.5 HP 2 HP 1.5 HP 2 HP 1.5 HP 2 HP RLA LRA FLA (1.1 (1.5 FLA (1.1 (1.5 (1.1 (1.5 (1.1 (1.5 (1.1 (1.5 ea. ea. ea. kW) kW) kW) kW) kW) kW) kW) kW) kW) kW) None - - 25.2 26.1 27.4


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21