York SUNLINE 2000 DM 072 user manual

User manual for the device York SUNLINE 2000 DM 072

Device: York SUNLINE 2000 DM 072
Category: Air Conditioner
Manufacturer: York
Size: 0.67 MB
Added : 2/7/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York SUNLINE 2000 DM 072. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York SUNLINE 2000 DM 072.

For your convenience

If looking through the York SUNLINE 2000 DM 072 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York SUNLINE 2000 DM 072 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York SUNLINE 2000 DM 072 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York SUNLINE 2000 DM 072 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York SUNLINE 2000 DM 072 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York SUNLINE 2000 DM 072. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

036-21502-003-A-1105
 
DESCRIPTION
YORK Sunline 2000™ units are convertible single package
TECHNICAL GUIDE
air conditioners with a common cabinet and a common roof
curb for the 3, 4, 5 and 6 ton sizes. The units were designed
for light commercial and commercial applications. They can
easily be installed on a roof curb, slab, roof jack or frame.
All units include:
SINGLE PACKAGE GAS/ELECTRIC UNITS
• Powder Paint finish that meets ASTM-B-117 1000 hour
AND SINGLE PACKAGE
salt spray standards

Summary of the content on the page No. 2

036-21502-003-A-1105 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 9 SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 20 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 10 SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 21 FACTORY-INSTALLED OPTIONS . . . . . . . . . .

Summary of the content on the page No. 3

036-21502-003-A-1105 PRODUCT NOMENCLATURE Unitary Products Group 3

Summary of the content on the page No. 4

036-21502-003-A-1105 PRODUCT NOMENCLATURE - Continued 3-6T Sunline Model Number Nomenclature Standard Cabinet AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Switch AE Phase Monitor & Coil Guard AF Phase Monitor & Dirty Filter Switch AG Coil Guard & Dirty Filter Switch AH Phase Monitor, Coil Guard, & Dirty Filter Switch AJ SS Drain Pan AK SS Drain Pan & Phase Monitor AL SS Drain Pan & Coil Guard AM SS Drain Pan & Dirty Filter Switch AN SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filte

Summary of the content on the page No. 5

036-21502-003-A-1105 Standard Cabinet JR Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard JS Johnson UNT Controller, DFS, APS, SS Drain Pan JT Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard JU Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils JV Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil JW Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils JX J

Summary of the content on the page No. 6

036-21502-003-A-1105 Standard Cabinet TD Technicoat Condenser Coil & Dirty Filter Switch TE Technicoat Condenser Coil, Phase Monitor, & Coil Guard TF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch TG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch TH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TJ Technicoat Evaporator Coil TK Technicoat Evaporator Coil & Phase Monitor TL Technicoat Evaporator Coil & Coil Guard TM Technicoat Evaporator

Summary of the content on the page No. 7

036-21502-003-A-1105 Standard Cabinet WF Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor WG Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard WH Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard WJ Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil WK Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor WL Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil

Summary of the content on the page No. 8

036-21502-003-A-1105 Hinged Filter Door & Toolless Access Cabinet DX CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels EA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels EB Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels EC Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & T

Summary of the content on the page No. 9

036-21502-003-A-1105 Hinged Filter Door & Toolless Access Cabinet PE Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels PF Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels PG Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels PH Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, H

Summary of the content on the page No. 10

036-21502-003-A-1105 Hinged Filter Door & Toolless Access Cabinet QG Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels QH Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access QJ Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels QK Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Ph

Summary of the content on the page No. 11

036-21502-003-A-1105 switch on gas heat units. The unit control board will FEATURES alarm on ignition failures, compressor lockouts and repeated limit switch trips. All models are available with a wide variety of factory- mounted options such as stainless steel heat exchangers, • Nuisance Trip Protection- To prevent nuisance electric heaters, phase monitor, convenience outlet, dirty filter trouble calls, the control board uses a “three strikes, switch, disconnect switch, smoke detectors,

Summary of the content on the page No. 12

036-21502-003-A-1105 FIGURE 1 - UNIT CUTAWAY TM FACTORY-INSTALLED OPTIONS Technicoat 10-1 processes. Coating is applied by total immersion of the complete coil for maximum protection. • SINGLE INPUT ELECTRONIC ENTHALPY ECONO- • ELECTRIC HEATERS - Wired for single point power MIZERS - Includes a slide-in / plug-in damper assembly supply. These nickel chromium heater elements are pro- with fully modulating spring-return motor actuator capa- vided with limit and automatic reset capability to pre

Summary of the content on the page No. 13

036-21502-003-A-1105 switch, an Outside Air Humidity sensor, a Return Air • STAINLESS STEEL HEAT EXCHANGER - For applica- Humidity sensor, an Inside IAQ sensor, and an Outside tions in corrosive environments, this option provides a Air IAQ sensor. Construction mode operation, 365-day full stainless steel heat exchanger assembly. real time clock with 7 day programming plus holiday • STAINLESS STEEL DRAIN PAN - An optional rust- scheduling is built-in. Two different modes of demand proof stainl

Summary of the content on the page No. 14

036-21502-003-A-1105 • ROOF CURBS - Eight and fourteen-inch high roof curbs • BAROMETRIC RELIEF DAMPER - This damper acces- provide a water-tight seal between the unit and the finished sory can be used to relieve internal building air pressure roof. These full perimeter curbs meet the requirements of on units with an economizer without power exhaust. This the National Roofing Contractors Association (NRCA) and accessory includes a rain hood, a bird screen and a fully are shipped knocked-down

Summary of the content on the page No. 15

036-21502-003-A-1105 1 TABLE 1: SOUND POWER RATING -12 SOUND POWER (db 10 Watts) ESP BLOWER UNIT Octave Band Centerline Frequency (Hz) dB(A) CFM SIZE SWL @ dB(A) IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 2 10Ft. 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 072 2,200 0.3 HIGH 1.35 87877770726560557744 1. These values have been accessed using a model of sound propagation

Summary of the content on the page No. 16

036-21502-003-A-1105 TABLE 5: DM036 COOLING CAPACITIES (3 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 SENSIBLE CAPACITY SENSIBLE CAPACITY TOTAL TOTAL COIL POWER POWER 1 1 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CAP. CAP. 2 2 INPUT kW INPUT kW MBH MBH CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 45 3.1 35 30 26 21 17 - - 43 3.3 35 30 26 21 17 - - 67 43 3.0 43 38 34 29 25 20 16 41 3.3 41 38 34 29 25 21 16 1750

Summary of the content on the page No. 17

036-21502-003-A-1105 TABLE 6: DM048 COOLING CAPACITIES (4 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 TOTAL SENSIBLE CAPACITY TOTAL SENSIBLE CAPACITY COIL POWER POWER 1 1 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CAP. CAP. 2 2 INPUT kW INPUT kW MBH MBH CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 60 4.1 44 39 33 28 23 - - 60 4.5 44 39 33 28 23 - - 67 55 4.1 53 48 42 37 32 26 21 52 4.5 52 47 42 36 31 25 20 2000 62 51 4.0 51 51 51 45 40 34 29 48 4.4 48 48

Summary of the content on the page No. 18

036-21502-003-A-1105 TABLE 7: DM060 COOLING CAPACITIES (5 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 TOTAL SENSIBLE CAPACITY TOTAL SENSIBLE CAPACITY COIL POWER POWER 1 1 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CAP. CAP. 2 2 INPUT kW INPUT kW MBH MBH CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 68 4.9 50 44 38 32 25 - - 65 5.6 50 43 37 31 24 - - 67 62 4.8 62 56 50 43 37 31 24 60 5.3 60 54 48 42 35 29 23 2500 62 57 4.7 57 57 57 51 44 38 32 53 5.3 53 53

Summary of the content on the page No. 19

036-21502-003-A-1105 TABLE 8: DM072 COOLING CAPACITIES (6 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 TOTAL SENSIBLE CAPACITY TOTAL SENSIBLE CAPACITY COIL POWER POWER 1 1 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CAP. CAP. 2 2 INPUT kW INPUT kW MBH MBH CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 80 5.7 63 55 47 40 32 - - 77 6.3 63 55 47 40 32 - - 67 80 5.7 76 68 60 53 45 37 30 77 6.3 75 68 60 53 45 37 30 2700 62 70 5.5 70 70 70 62 55 47 39 71 6.3 71 71

Summary of the content on the page No. 20

036-21502-003-A-1105 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION 3 AVAILABLE EXTERNAL STATIC PRESSURE-IWG AIR UNIT FLOW 0.20 0.30 0.40 0.50 0.60 0.70 0.80 TONNAGE CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 1700 835 705 880 745 923 795 969 860 1013 970 ---- 1600 811 655 854 695 898 740 942 790 986 840 1029 900 - - 1500 782 610 827 650 871 685 917 730 960 775 1003 825 1046 905 1400 - - 798 595 844 640 889 680 932 720 975 765 101


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21