York SUNLINE MAGNUM DY 060 user manual

User manual for the device York SUNLINE MAGNUM DY 060

Device: York SUNLINE MAGNUM DY 060
Category: Air Conditioner
Manufacturer: York
Size: 2.19 MB
Added : 2/7/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York SUNLINE MAGNUM DY 060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York SUNLINE MAGNUM DY 060.

For your convenience

If looking through the York SUNLINE MAGNUM DY 060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York SUNLINE MAGNUM DY 060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York SUNLINE MAGNUM DY 060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York SUNLINE MAGNUM DY 060 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York SUNLINE MAGNUM DY 060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York SUNLINE MAGNUM DY 060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

343615-YTG-B-0308
 
DESCRIPTION
YORK Sunline Magnum™ units are convertible single pack-
TECHNICAL GUIDE
age air conditioners with a common cabinet and a common
roof curb for the 3, 4 and 5 ton sizes. The units were
designed for light commercial and commercial applications.
They can easily be installed on a roof curb, slab, roof jack or
frame.
SINGLE PACKAGE GAS/ELECTRIC UNITS
All units include:
AND SINGLE PACKAGE • Powder Paint finish that meets ASTM-B-117 750 hour salt
spray standards
AI

Summary of the content on the page No. 2

343615-YTG-B-0308 TABLE OF CONTENTS Pg. # DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 8 DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . . . . 11 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 9 DY048 INDOOR SOUND POWER LEVELS FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . 6 (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . . . . 11 FI

Summary of the content on the page No. 3

343615-YTG-B-0308 PRODUCT NOMENCLATURE 3-5 Ton Sunline Magnum™ Model Number Nomenclature D Y 048 N04 A 2 A AA 2 0 1 2 4 A Product Category Product Style D = A/C, Single Pkg., R-22 A = Style A Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. Y = 14.0 SEER SS Drain Pan CPC Controller, DFS, APS Johnson Controller, DFS, APS Nominal Cooling Capacity Honeywell Controller, DFS, APS 036 = 3.0 Ton

Summary of the content on the page No. 4

343615-YTG-B-0308 gas valve, if applicable, and the temperature limit FEATURES switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and All models are available with a wide variety of factory- repeated limit switch trips. mounted options such as stainless steel heat exchangers, electric heaters, phase monitor, convenience outlet, dirty filter • Nuisance Trip Protection- To prevent nuisance switch, disconnect switch, smoke detectors, and coil

Summary of the content on the page No. 5

343615-YTG-B-0308 Gas/Electric Electric heat accessory location 20 Gauge aluminized Power ventor motor with steel tubular heat exchanger post purge cycle Direct drive High efficiency HACR blower compressor breaker Economizer hood Copper tube/ aluminum fin condensing coil Knockout for side power entry Slide-in economizer Smoke detector Full perimeter baserails with forklift slots and lifting holes Knockout for side 3/4" PVC female gas supply entry condensate drain GFCI Simplicity® Lite™ convenie

Summary of the content on the page No. 6

343615-YTG-B-0308 scheduling is built-in. Two different modes of demand FACTORY-INSTALLED OPTIONS ventilation are achieved through the INTELLI-Comfort™ • SINGLE INPUT ELECTRONIC ENTHALPY ECONO- using CO2 sensors. It uses an inside CO2 sensor to per- MIZERS - Includes a slide-in / plug-in damper assembly form Demand Ventilation. It can also use an Outside with fully modulating spring-return motor actuator capa- CO2 sensor to perform Differential Demand Ventilation. ble of introducing up to 1

Summary of the content on the page No. 7

343615-YTG-B-0308 • MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in / plug-in damper assembly with a 2- position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is Factory installed Smoke Detectors in the Return operating and will drive fully closed when the blower unit Air, may be subjected to freezing temperatures shuts down. during "off" times due to Out Side Air infiltration. These Smoke Detectors have an operational limit The r

Summary of the content on the page No. 8

343615-YTG-B-0308 • ENTHALPY ACCESSORY CONTROL KIT - This kit • CO SENSOR - Senses CO levels and automatically 2 2 contains the required components to convert a single overrides the economizer when levels rise above the enthalpy economizer to dual enthalpy. present limits. • BURGLAR BARS - Mount in the supply and return • COIL GUARD - Customers can purchase a coil guard kit openings to prevent entry into the duct work. to protect the condenser coil from damage. This is not a hail guard kit.

Summary of the content on the page No. 9

343615-YTG-B-0308 TABLE 4: DY036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY036 / 3 Ton CONFIGURATION Horizontal Ducted Inlet Indoor Blower Speed (RPM) 630 631 879 885 Blower Static Pressure (IWG) 0.2 0.3 0.2 0.7 Airflow (CFM) 1116 928 1979 1020 Blower Motor BHP 0.41 0.37 0.76 0.53 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (dB) On

Summary of the content on the page No. 10

343615-YTG-B-0308 TABLE 6: DY036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY036 / 3 Ton CONFIGURATION Vertical Ducted Inlet Indoor Blower Speed (RPM) 632 632 881 883 Blower Static Pressure (IWG) 0.2 0.3 0.2 0.7 Airflow (CFM) 1069 870 1903 917 Blower Motor BHP 0.36 0.33 0.71 0.49 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (dB) Only (dB) (dB)

Summary of the content on the page No. 11

343615-YTG-B-0308 TABLE 8: DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY048 / 4 Ton CONFIGURATION Horizontal Ducted Inlet Indoor Blower Speed (RPM) 766 769 1077 1087 Blower Static Pressure (IWG) 0.2 0.5 0.4 1.0 Airflow (CFM) 1484 993 2270 1406 Blower Motor BHP 0.67 0.54 1.24 0.90 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (dB) Only (dB

Summary of the content on the page No. 12

343615-YTG-B-0308 TABLE 10: DY048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY048 / 4 Ton CONFIGURATION Vertical Ducted Inlet Indoor Blower Speed (RPM) 791 794 1084 1095 Blower Static Pressure (IWG) 0.2 0.5 0.2 1.0 Airflow (CFM) 1408 1000 2336 1275 Blower Motor BHP 0.54 0.42 1.12 0.73 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (dB) Only (dB)

Summary of the content on the page No. 13

343615-YTG-B-0308 TABLE 12: DY060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY060 / 5 Ton CONFIGURATION Horizontal Ducted Inlet Indoor Blower Speed (RPM) 840 845 1166 1188 Blower Static Pressure (IWG) 0.2 0.6 0.3 1.3 Airflow (CFM) 1695 1100 2618 1323 Blower Motor BHP 0.67 0.50 1.51 0.80 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (dB) Only (

Summary of the content on the page No. 14

343615-YTG-B-0308 TABLE 14: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL DY060 / 5 Ton CONFIGURATION Vertical Ducted Inlet Indoor Blower Speed (RPM) 834 840 1171 1194 Blower Static Pressure (IWG) 0.2 0.6 0.2 1.3 Airflow (CFM) 1525 1019 2624 1256 Blower Motor BHP 0.61 0.44 1.43 0.83 Cooling Cooling Cooling Cooling ID Blower ID Blower ID Blower ID Blower 2 2 2 2 Octave Center Freq. Operation Operation Operation Operation Only (dB) Only (dB) Only (d

Summary of the content on the page No. 15

343615-YTG-B-0308 TABLE 16: DY036 COOLING CAPACITIES (3 TON) Temperature of Air on Condenser Coil Air on Evap- orator Coil 75°F 85°F 1 1 2 2 Sensible Capacity (MBH) Sensible Capacity (MBH) Total Total Total Total WB 1 1 Return Dry Bulb (°F) Return Dry Bulb (°F) CFM Cap. Input Cap. Input (°F) (MBH) (kW) (MBH) (kW) 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 44 2.3 24 21 19 16 14 - - 41 2.5 23 20 18 15 12 - - 67 42 2.3 30 28 25 23 20 18 15 38 2.5 29 26 24 21 18 16 13 900 62 40 2.3 40 35 33 30 28

Summary of the content on the page No. 16

343615-YTG-B-0308 TABLE 17: DY048 COOLING CAPACITIES (4 TON) Temperature of Air on Condenser Coil Air on Evap- orator Coil 75°F 85°F 1 1 2 2 Sensible Capacity (MBH) Sensible Capacity (MBH) Total Total Total Total WB 1 1 Return Dry Bulb (°F) Return Dry Bulb (°F) CFM Cap. Input Cap. Input (°F) (MBH) (kW) (MBH) (kW) 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 58 2.8 32 28 25 22 18 - - 54 3.1 30 27 23 20 17 - - 67 57 2.8 43 39 36 32 29 26 22 51 3.1 40 36 33 29 26 23 19 1200 62 53 2.8 53 47 44 40 37

Summary of the content on the page No. 17

343615-YTG-B-0308 TABLE 18: DY060 COOLING CAPACITIES (5 TON) Temperature of Air on Condenser Coil Air on Evap- orator Coil 75°F 85°F 1 1 2 2 Sensible Capacity (MBH) Sensible Capacity (MBH) Total Total Total Total WB 1 1 Return Dry Bulb (°F) Return Dry Bulb (°F) CFM Cap. Input Cap. Input (°F) (MBH) (kW) (MBH) (kW) 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 73.9 3.7 39.9 35.6 31.3 27.0 22.8 - - 69.2 4.3 38.6 34.3 30.1 25.8 21.5 - - 67 67.1 3.7 50.5 46.3 42.0 37.7 33.4 29.2 24.9 63.1 4.2 48.9 44.

Summary of the content on the page No. 18

343615-YTG-B-0308 TABLE 19: SUPPLY AIR BLOWER PERFORMANCE (DY036, 048, & 060 DIRECT DRIVE) SIDE DUCT APPLICATION 2 AVAILABLE EXTERNAL STATIC PRESSURE - IWG 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1 UNIT MOTOR TONNAGE SPEED HI 1582 320 1538 335 1496 349 1458 363 1418 376 1381 390 1338 403 1298 417 1255 430 MED/HI 1488 263 1440 276 1396 290 1354 303 1309 316 1263 329 1214 343 1158 358 1085 374 3 3 MED 1339 208 1292 221 1247 234 1201 246 1152 258 1102 272 1036 288 967 303 924 313 MED/LOW 1233 171 118

Summary of the content on the page No. 19

343615-YTG-B-0308 TABLE 21: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 1,3 ECONOMIZER 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 7-15KW 0.040.050.060.070.080.100.120.140.160.190.22 ELECTRIC 1 HEATERS 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 2 COOLING ONLY 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 1. Deduct these resistance values from the available external static pressure shown in SUPPL

Summary of the content on the page No. 20

343615-YTG-B-0308 TABLE 23: ELECTRICAL DATA - DY036, 048 & 060 DIRECT DRIVE W/O POWERED CONVENIENCE OUTLET OD Fan Supply Pwr Max Compressors 2 Motors Blower Conv Electric Heat Option Fuse / 1 Size (each) MCA 3 Volt (each) Motor Outlet Breaker (Tons) (Amps) Size RLA LRA MCC FLA FLA FLA Model kW Stages Amps (Amps) None - - - 22.4 30 E05 4.0 1 19.2 31.5 35 E07 5.6 1 26.9 41.2 45 208-1-60 11.3 68.0 17.5 2.3 6.0 0.0 E10 8.0 1 38.5 55.6 60 E15 11.9 2 57.2 79.0 80 E20 15.9 2 76.4 103.1 110 None - -


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21