York SUNLINE PLUS D1EG user manual

User manual for the device York SUNLINE PLUS D1EG

Device: York SUNLINE PLUS D1EG
Category: Air Conditioner
Manufacturer: York
Size: 2.88 MB
Added : 2/7/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York SUNLINE PLUS D1EG. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York SUNLINE PLUS D1EG.

For your convenience

If looking through the York SUNLINE PLUS D1EG user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York SUNLINE PLUS D1EG on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York SUNLINE PLUS D1EG to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York SUNLINE PLUS D1EG User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York SUNLINE PLUS D1EG but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York SUNLINE PLUS D1EG. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

036-21411-002-A-0204

TECHNICAL GUIDE FLEXIBLE EASY TO INSTALL SINGLE
PACKAGE UNITS.
SUNLINE PLUS™
GENERAL
AIR-COOLED
YORK Model DEE/DEG units are single package air condi-
AIR CONDITIONERS
tioners designed for outdoor installation on a rooftop or a
slab. These units can be equipped with field installed elec-
D1EG/D1EE036, 048, & 060
tric heaters for cooling/heating applications or factory
3, 4, AND 5 NOMINAL TONS installed gas heat. The units are completely assembled on
rigid, permanently

Summary of the content on the page No. 2

036-21411-002-A-0204 TABLE OF CONTENTS DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 SOUND POWER RATINGS . . . . . . . . . . . . . . . . . . . . . . 7 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 PHYSICAL DATA - BASIC UNIT . . . . . . . . . . . . . . . . . . 8 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . 4 5 COOLING CAPACITIES - 3 TON (DEE / DEG036) . . . . 9 FIELD-INSTALLED ACCESSORIES. . . . . . . . . . . . . 4 6 COOLING CAP

Summary of the content on the page No. 3

036-21411-002-A-0204 Adjustable belt drive blowers are available on all models from DESCRIPTION the factory for complete airflow flexibility. YORK Sunline Plus™ units are high efficiency, convertible, FIELD--INSTALLED ACCESSORIES -- Accessories were single package air conditioners with a common cabinet and a designed for quick and easy installation. The motorized common roof curb for the 3, 4 and 5 ton sizes. The units were damper and economizers simply slide in, and electrical con- designed for

Summary of the content on the page No. 4

036-21411-002-A-0204 voltage terminal strip. An additional set of pin connectors is DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - also provided to simplify the field interface of external con- Includes the same damper system and rain hood with filters trols. Mate--n--lock plug connectors are used where line and as described for a single enthalpy economizer except this low voltage wires pass through internal bulkheads. This accessory contains two enthalpy sensors. It uses a differen- allows for eas

Summary of the content on the page No. 5

036-21411-002-A-0204 PROPANE CONVERSION KIT - Converts a gas-fired heater GAS PIPING - This kit contains 1/2" pipe nipples, fittings and from natural gas to propane. It contains main burner orifices, gas cock (including panel access gaskets) required for bot- a pilot orifice and a regulator spring. tom gas supply connection with external shut-off. LOW NOx KIT (natural gas furnaces only) - Contains five OUTDOOR COIL GUARD - Consists of grille-type sections stainless steel expanded metal sheets fo

Summary of the content on the page No. 6

036-21411-002-A-0204 TABLE 1: CAPACITY RATINGS - COOLING / ELECTRIC HEATING 1 ARI RATINGS 2 NOMINAL ELECTRIC HEAT CAPACITY (kW) COOLING CAPACITY 80 / 67-95°F SOUND MODEL 3 RATING 4 5 MBH 240V 480V 600V SEER EER (dBels) 5, 7, 10, 15 & DEE036 42.5 11.5 10.10 86.0 7, 10, 15 & 20 10, 15, & 20 20 5, 7, 10, 15 & DEE048 49.5 11.0 10.0 86.0 7, 10, 15 & 20 10, 15, & 20 20 5, 7, 10, 15, 7, 10, 15, 10, 10, 15, 20 & DEE060 58.5 11.0 10.05 86.0 20, & 30 & 30 30 1. Certified in accordance with the Unitary

Summary of the content on the page No. 7

036-21411-002-A-0204 TABLE 4: PHYSICAL DATA - BASIC UNIT DEE/DEG MODELS 036 048 060 Centrifugal Blower (Dia. x Wd. in.) 12 x 10 12 x 10 12 x 10 EVAPORATOR Fan Motor HP (Direct - Drive) 1/2 3/4 1 BLOWER Fan Motor HP (Belt - Drive) 1.5 1.5 1.5 Rows Deep 3 3 3 EVAPORATOR Fins Per Inch 13 13 13 COIL Face Area (Sq. Ft.) 3.6 4.3 5.1 Propeller Dia. (in.) 22 22 22 CONDENSER Fan Motor HP 1/2 1/2 1/2 FAN Nom. CFM. Total 4,500 4,200 4,500 Rows Deep 2 2 2 CONDENSER Fins Per Inch 18 18 18 COIL Face Area (Sq.

Summary of the content on the page No. 8

036-21411-002-A-0204 TABLE 5: COOLING CAPACITIES - 3 TON (DEE / DEG036) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 SENSIBLE CAPACITY , MBH SENSIBLE CAPACITY , MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 .1 2 CAP. INPUT CAP INPUT WB MBH kW MBH kW. CFM 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F 72 55 3.4 35 31 26 22 18 - - 51 3.7 35 30 26 21 17 - - 67 52 3.3 47 42 38 33 29 24 20 48 3.6 45 41 36 32 28 23 19 1500 62 42 3.2 42 42 42 37

Summary of the content on the page No. 9

036-21411-002-A-0204 TABLE 6: COOLING CAPACITIES - 4 TON (DEE / DEG048) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 SENSIBLE CAPACITY , MBH SENSIBLE CAPACITY , MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 .1 2 CAP. INPUT CAP INPUT WB MBH kW MBH kW. CFM 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F 72 64 3.9 45 39 33 27 21 - - 60 4.2 44 38 32 26 20 - - 67 57 3.8 55494337312519 53 4.1 53 47 41 35 29 23 17 2000 62 54 3.8 54 54 53 47 41 35

Summary of the content on the page No. 10

036-21411-002-A-0204 TABLE 7: COOLING CAPACITIES - 5 TON (DEE / DEG060) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON 85°F 95°F EVAPORATOR 1 1 SENSIBLE CAPACITY , MBH SENSIBLE CAPACITY , MBH COIL TOTAL POWER TOTAL POWER ENTERING DRY BULB, °F ENTERING DRY BULB, °F 1 2 .1 2 CAP. INPUT CAP INPUT WB MBH kW MBH kW. CFM 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F 72 75 4.6 53 46 38 31 23 - - 73 5.0 53 46 38 31 23 - - 67 67 4.5 64 56 49 41 34 26 19 65 4.9 64 56 49 41 34 26 19 2500 62 62 4.5 62 62 62 54

Summary of the content on the page No. 11

036-21411-002-A-0204 1 2 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG036 W/ BELT DRIVE & SIDE DUCT 3 AVAILABLE EXTERNAL STATIC PRESSURE - IWG AIR MODEL FLOW 0.20 0.30 0.40 0.50 0.60 0.70 0.80 DEE/DEG CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 74

Summary of the content on the page No. 12

036-21411-002-A-0204 1 2 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG048 W/ BELT DRIVE & SIDE DUCT 3 AVAILABLE EXTERNAL STATIC PRESSURE - IWG AIR MODEL FLOW 0.20 0.30 0.40 0.50 0.60 0.70 0.80 DEE/DEG CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 74

Summary of the content on the page No. 13

036-21411-002-A-0204 1 2 TABLE 10: SUPPLY AIR BLOWER PERFORMANCE -DEE/DEG060 W/ BELT DRIVE & SIDE DUCT 3 AVAILABLE EXTERNAL STATIC PRESSURE - IWG AIR MODEL FLOW 0.20 0.30 0.40 0.50 0.60 0.70 0.80 DEE/DEG CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142

Summary of the content on the page No. 14

036-21411-002-A-0204 1 TABLE 11: SUPPLY AIR BLOWER PERFORMANCE - DEE/DEG036-060 W/ DIRECT DRIVE 2 AVAILABLE EXTERNAL STATIC PRESSURE - IWG MODEL MOTOR 0.20 0.30 0.40 0.50 DEE/DEG SPEED CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI - - - - 1699 825 1650 785 036 MED 1684 800 1631 780 1582 750 1524 720 LOW 1487 710 1464 690 1421 670 1367 650 HI 1996 960 1933 936 1868 910 1795 880 048 MED 1804 838 1765 810 1714 785 1650 765 LOW 1681 760 1640 738 1604 715 1541 695 HI 2400 1155 2338 1125 2274 1095 2167 1

Summary of the content on the page No. 15

036-21411-002-A-0204 TABLE 13: MOTOR AND DRIVE DATA - BELT-DRIVE BLOWER ADJUSTABLE FIXED 1 BELT MOTOR MOTOR PULLEY BLOWER PULLEY BLOWER MODEL RANGE PITCH PITCH PITCH FRAME SERVICE BORE BORE DESIG- RPM HP RPM DIA. DIA. LENGTH SIZE FACTOR (in.) (in.) NATION (in.) (in.) (in.) DEE / DEG 036 780 - 1120 1-1/2 1725 56 1.15 2.4-3.4 7/8 5.7 1 37.3 A36 DEE / DEG 048 790 - 1120 1-1/2 1725 56 1.15 2.4-3.4 7/8 5.7 1 37.3 A36 DEE / DEG 060 850 - 1220 1-1/2 1725 56 1.15 2.4-3.4 7/8 5.2 1 37.3 A36 1. All motors

Summary of the content on the page No. 16

036-21411-002-A-0204 TABLE 15: BASIC UNIT W/ BELT-DRIVE ELECTRICAL DATA VOLTAGE SUPPLY MAX. MAX. CON. COMPRESSOR 1 MODEL AIR MINIMUM HACR LIMITATIONS FUSE POWER FAN DEE/ BLOWER CIRCUIT BREAKER 2 SUPPLY MOTOR, SIZE DEG MOTOR, AMPACITY SIZE, MIN MAX RLA LRA FLA AMPS FLA AMPS 208/230-1-60 187 253 16.7 87 2.3 7.6 30.1 45 45 208/230-3-60 187 253 13.1 110 2.3 5.3 23.9 35 35 036 460-3-60 414 504 6.7 54 1.4 2.6 12.4 20 20 3 518 630 5.1 44 1.4 2.0 9.8 15 15 575-3-60 208/230-1-60 187 253 18.7 135 2.3 8.6

Summary of the content on the page No. 17

036-21411-002-A-0204 TABLE 16: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE036 SUPPLY ELECTRIC HEATERS MAX HEATER MAX. AIR MINIMUM FUSE MODEL POWER ACCESSORY SIZE BLOWER CIRCUIT TOTAL 1 DEE SUPPLY MODEL kW STAGES SIZE 2 MOTOR AMPACITY AMPS HACR NUMBER AMPS FLA 2CE04500506 4.0 1 19.1 30.7 45 45 2CE04500706 5.6 1 27.1 39.4 45 45 208-1-60 2CE04501006 4.4 8.0 1 38.3 53.4 60 60 2CE04501506 11.9 2 57.4 77.3 80 80 2CE04502006 15.9 2 76.6 101.2 110 110 2CE04500506 5.3 1 22.1 33.1 45 45 2CE

Summary of the content on the page No. 18

036-21411-002-A-0204 TABLE 17: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE048 SUPPLY ELECTRIC HEATERS MAX HEATER MAX. AIR MINIMUM FUSE MODEL POWER ACCESSORY SIZE BLOWER CIRCUIT TOTAL 1 DEE SUPPLY MODEL kW STAGES SIZE 2 MOTOR AMPACITY AMPS HACR NUMBER AMPS FLA 2CE04500506 4.0 1 19.1 38.6 60 60 2CE04500706 5.6 1 27.1 39.9 60 60 208-1-60 2CE04501006 5.0 8.0 1 38.3 54.3 60 60 2CE04501506 11.9 2 57.4 77.8 80 80 2CE04502006 15.9 2 76.6 101.8 110 110 2CE04500506 5.3 1 22.1 38.6 60 60 2CE

Summary of the content on the page No. 19

036-21411-002-A-0204 TABLE 20: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ DIRECT DRIVE DEE060 ELECTRIC HEATERS MAX. SUPPLY MAX. HEATER SIZE AIR MINIMUM FUSE MODEL POWER ACCESSORY 2 BLOWER CIRCUIT TOTAL HACR 1 DEE SUPPLY MODEL kW STAGES SIZE MOTOR AMPACITY AMPS BREAKER NUMBER AMPS FLA AMPS 2CE04500506 4.0 1 19.1 49.0 80 80 2CE04500706 5.6 1 27.1 49.0 80 80 2CE04501006 8.0 1 38.3 56.1 80 80 208-1-60 8.6 2CE04501506 11.9 2 57.4 80.0 90 90 2CE04502006 15.9 2 76.6 103.9 110 110 2CE04503006 22.2 2 106.9

Summary of the content on the page No. 20

036-21411-002-A-0204 TABLE 21: ELECTRICAL DATA COOLING/ELECTRIC HEAT W/ BELT DRIVE DEE036 & 048 ELECTRIC HEATERS MAX. SUPPLY MAX. HEATER SIZE AIR MINIMUM FUSE MODEL POWER ACCESSORY 2 BLOWER CIRCUIT TOTAL HACR 1 DEE SUPPLY MODEL kW STAGES SIZE MOTOR AMPACITY AMPS BREAKER NUMBER AMPS FLA AMPS 2CE04500506 4.0 1 19.1 34.9 50 50 2CE04500706 5.6 1 27.1 44.6 50 50 208-1-60 2CE04501006 5.3 8.0 1 38.3 58.6 60 60 2CE04501506 11.9 2 57.4 82.5 90 90 2CE04502006 15.9 2 76.6 106.4 110 110 2CE04500506 5.3 1 22


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21