York YCAL0065 user manual

User manual for the device York YCAL0065

Device: York YCAL0065
Category: Air Conditioner
Manufacturer: York
Size: 1.95 MB
Added : 2/7/2014
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York YCAL0065. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York YCAL0065.

For your convenience

If looking through the York YCAL0065 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York YCAL0065 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York YCAL0065 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York YCAL0065 User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York YCAL0065 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York YCAL0065. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FORM 150.64-EG1 (505)
AIR-COOLED
SCROLL CHILLERS
STYLE D
YCAL0041 – YCAL0065
50 AND 60HZ
47 – 60 TON
165 – 210 KW
R-22

Summary of the content on the page No. 2

Table of Contents FORM 150.64-EG1 (405) ....................................................................................................................................................................................... 1 Introduction ........................................................................................................................................................................................................... 3 Specification ..........................................

Summary of the content on the page No. 3

FORM 150.64-EG1 Introduction YORK Air-Cooled Scroll Chillers provide chilled water for all air conditioning applications using central station air handling or terminal units. They are completely self-contained and are designed for outdoor (roof or ground level) installation. Each unit includes hermetic scroll compressors, a liquid cooler, air cooled condenser, and a weather resistant microprocessor control center, all mounted on a pressed steel base. YORK INTERNATIONAL 3

Summary of the content on the page No. 4

Specification GENERAL tion for the cooler down to -20°F (-29°C) ambient. The cooler is covered with 3/4” (19mm) flexible, closed-cell, The 47 - 60 Ton (165 - 210 kW) YCAL models are foam insulation (K~0.25). shipped complete from the factory ready for installation and use. Brazed plate heat exchangers shall be UL (Underwriters Laboratories) listed. Installing contractor must include The unit is pressure-tested, evacuated, and fully charged accommodations in the chilled water piping to allow

Summary of the content on the page No. 5

FORM 150.64-EG1 MILLENNIUM CONTROL CENTER All controls are contained in a NEMA 3R/12 (and equivalent to IP55*) cabinet with hinged outer door and UNIT ON/OFF switch includes: The microprocessor control center is capable of dis- Liquid Crystal Display with Light Emitting Diode back- playing the following: lighting for outdoor viewing: Two display lines • Return and leaving liquid temperature Twenty characters per line • Low leaving liquid temperature cutout setting Color coded 12-button

Summary of the content on the page No. 6

Provisions are included for: pumpdown at shutdown; POWER PANEL optional remote chilled water temperature reset and two steps of demand load limiting from an external building Each panel contains: automation system. Unit alarm contacts are standard. • Compressor power terminals • Compressor motor starting contactors per l.E.C.** The operating program is stored in non-volatile memory • Control power terminals to accept incoming for (EPROM) to eliminate chiller failure due to AC powered fail

Summary of the content on the page No. 7

FORM 150.64-EG1 Options and Accessories includes the Discharge Pressure Transducer / Readout- POWER OPTIONS: Capability option.) (Field-Mounted.) COMPRESSOR POWER CONNECTIONS – Single- BUILDING AUTOMATION SYSTEM INTERFACE – The point (YCAL0041-0065) terminal block connection(s) are factory addition of a Printed Circuit Board to accept a provided as standard. The following power connections 4-20 milliamp, 0-10VDC or contact closure input to reset are available as options. (See electrical dat

Summary of the content on the page No. 8

chilling below 30°F (-1°C) leaving brine temperature REMOTE DX COOLER – A split system arrangement for YCAL0041 - 0065 models. Option includes resized with the cooler, leaving & return water sensors, liquid thermal expansion valve. (Factory-Mounted) line solenoid valves, filter driers, sightglasses & TXVs shipped loose for field connection to the air-cooled con- CHICAGO CODE RELIEF VALVES – Unit will be pro- densing section. The DX cooler and outdoor section will vided with relief valves to me

Summary of the content on the page No. 9

FORM 150.64-EG1 residential or other similar sound-sensitive locations. of welded PVC, reinforced for temperature and UV Louvered Panels can be ordered for winter applications resistance. (Factory-Mounted.) where wind gusts may exceed five miles per hour. The following types of enclosure options are available: ULTRA QUIET FANS – Lower RPM, 8-pole fan motors are used with steeper-pitch fans. (Factory-Mounted.) COMPRESSOR ACOUSTIC SOUND BLANKET – Each compressor is individually enclosed by an a

Summary of the content on the page No. 10

This page intentionally left blank. 10 YORK INTERNATIONAL

Summary of the content on the page No. 11

FORM 150.64-EG1 Selection Data GUIDE TO SELECTION 6. Ethylene Glycol Correction Factors – The fol- lowing factors are to be applied to the standard Capacity ratings for YORK YCAL Packaged Air-Cooled ratings for units cooling ethylene glycol. Liquid Chillers, shown on pages 16 through 39 cover ETHYLENE GLYCOL the majority of design applications for these units. For % COMPR GPM PRESS FREEZE unusual applications or uses beyond the scope of this TONS WEIGHT KW °F/TON DROP PT catalog, please co

Summary of the content on the page No. 12

a. 56.1 Tons 7. Determine average full load Compressor kW at 34 tons b. 55.9 Compressor KW c. 10.7 Unit EER 3 4 t o n s x ( 4 1 . 7 7 ) = 4 1 . 9 3 C o m p r e s s o r k W 4. Calculate Compressor kW at 50 Tons: 3 3 . 8 7 t o n s 8. Determine E.G. GPM: 5 0 k W = x 5 5 . 9 k W = 4 9 . 8 k W T o n s × G a l . ° F / m i n / T o n f a c t o r 5 6 . 1 G P M = 5. Calculate GPM: R a n g e 3 4 . 0 × 2 6 . 1 G P M = = 8 8 . 7 ( G P M ) ( 5 0 T o n s ) × 2 4 1 0 G P M = = 1

Summary of the content on the page No. 13

FORM 150.64-EG1 Design Parameters ENGLISH LEAVING WATER YCAL COOLER FLOW (GPM) AIR ON CONDENSER (°F) TEMPERATURE (°F) MIN MAX MIN MAX MIN MAX 0041 40 55 40 200 0 125 0045 40 55 40 200 0 125 0051 40 55 40 200 0 125 0055 40 55 60 300 0 125 0061 40 55 60 300 0 125 0065 40 55 60 300 0 125 SI UNITS LEAVING WATER YCAL COOLER FLOW (L/S) AIR ON CONDENSER (°C) TEMPERATURE (°DC) MIN MAX MIN MAX MIN MAX 0041 4.4 12.8 2.5 12.6 -17.7 51.7 0045 4.4 12.8 2.5 12.6 -17.7 51.7 0051 4.4 12.8 2.5 12.6 -17.7 51.7 00

Summary of the content on the page No. 14

Water Pressure Drop ENGLISH 100 A C D B 10 1 10 100 1000 FLOW, GPM Note: Water Pressure Drop Curves may extend past the minimum and maximum water flow ranges. See page 13 for minimum and maximum flow points. 14 YORK INTERNATIONAL Press Drop, Ft H O 2

Summary of the content on the page No. 15

FORM 150.64-EG1 SI 1000 A C B D 100 10 1 1 10 100 FLOW, L/S Note: Water Pressure Drop Curves may extend past the minimum and maximum water flow ranges. See page 13 for minimum and maximum flow points. YORK INTERNATIONAL 15 Press Drop, kPA

Summary of the content on the page No. 16

Ratings - R-22 (60Hz - English Units) IPLV= 13.9 MODEL: YCAL0041EC AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 35.8 30.3 12.0 35.1 32.0 11.2 34.4 33.8 10.5 33.7 35.7 9.8 32.9 37.7 9.1 32.1 39.9 8.5 42.0 37.0 30.6 12.3 36.2 32.2 11.5 35.5 34.0 10.8 34.8 35.9 10.0 34.0 38.0 9.4 33.2 40.1 8.7 44.0 38.1 30.8 12.6 37.4 32.5 11.8 36.7 34.3 11.0 35.9 36.2 10.3 35.1 38.2 9.6 34.3 40.4 8.9 45.

Summary of the content on the page No. 17

FORM 150.64-EG1 IPLV= 13.9 MODEL: YCAL0041EC AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 31.3 42.2 7.9 30.5 44.7 7.3 29.6 47.4 6.7 28.7 50.2 6.2 27.8 53.2 5.7 42.0 32.4 42.5 8.1 31.5 45.0 7.5 30.6 47.6 6.9 29.7 50.4 6.4 28.7 53.4 5.8 44.0 33.4 42.7 8.3 32.5 45.2 7.7 31.6 47.9 7.1 30.7 50.7 6.5 29.7 53.7 6.0 45.0 34.0 42.9 8.4 33.1 45.3 7.8 32.1 48.0 7.2 31.2 50.8 6.6 30.2 53.8 6.1 46.0 34.5 43.0 8.5

Summary of the content on the page No. 18

Ratings - R-22 (60Hz - English Units) - Cont. IPLV= 13.6 MODEL: YCAL0055EC AIR TEMPERATURE ON - CONDENSER (°F) 75.0 80.0 85.0 90.0 95.0 100.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 48.6 42.1 11.9 47.6 44.4 11.2 46.6 46.8 10.5 45.6 49.4 9.7 44.6 52.2 9.1 43.5 55.1 8.4 42.0 50.2 42.4 12.3 49.2 44.7 11.5 48.2 47.1 10.7 47.1 49.7 10.0 46.1 52.5 9.3 44.9 55.4 8.7 44.0 51.8 42.7 12.6 50.8 44.9 11.8 49.8 47.4 11.0 48.7 50.0 10.3 47.6 52.8 9.6 46.4 55.7

Summary of the content on the page No. 19

FORM 150.64-EG1 IPLV= 13.6 MODEL: YCAL0055EC AIR TEMPERATURE ON - CONDENSER (°F) 105 110.0 115.0 120.0 125.0 LCWT (°F) TONS KW EER TONS KW EER TONS KW EER TONS KW EER TONS KW EER 40.0 42.3 58.2 7.8 41.2 61.4 7.2 39.9 64.8 6.7 29.0 48.0 6.4 28.0 50.6 5.9 42.0 43.8 58.5 8.1 42.6 61.8 7.5 41.3 65.2 6.9 30.0 48.3 6.6 29.0 50.9 6.0 44.0 45.3 58.8 8.3 44.0 62.1 7.7 42.7 65.6 7.1 31.1 48.5 6.8 30.1 51.2 6.2 45.0 46.0 59.0 8.4 44.7 62.3 7.8 43.4 65.8 7.2 31.6 48.6 6.9 30.6 51.3 6.3 46.0 46.8 59.1 8.5

Summary of the content on the page No. 20

Ratings - R-22 (60Hz - SI Units) MODEL: YCAL0041EC AIR TEMPERATURE ON - CONDENSER (°C) 25.0 30.0 35.0 40.0 45.0 50.0 LCWT (°C) KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP KW KW COP 5.0 126.9 31.1 3.5 122.4 34.3 3.1 117.6 37.9 2.7 112.5 41.9 2.4 107.1 46.4 2.1 101.3 51.5 1.8 6.0 130.6 31.3 3.5 125.9 34.5 3.1 121.0 38.1 2.8 115.8 42.1 2.4 110.3 46.6 2.1 104.4 51.7 1.8 7.0 134.3 31.6 3.6 129.6 34.7 3.2 124.5 38.3 2.8 119.2 42.3 2.5 113.6 46.9 2.2 107.6 51.9 1.9 8.0 138.1 31.8 3.7 133.2 35.0


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21