York YMB user manual

User manual for the device York YMB

Device: York YMB
Category: Air Conditioner
Manufacturer: York
Size: 0.63 MB
Added : 5/22/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York YMB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York YMB.

For your convenience

If looking through the York YMB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York YMB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York YMB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York YMB User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York YMB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York YMB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FAN COIL
AIR CONDITIONERS
NEW RELEASE
Form 115.20-NOM4 (105)
INSTALLATION, OPERATION, & MAINTENANCE
MODELS: YMB, YMB-HW, YMBE
YMB Series
(2-pipe, cooling and heating)
(Replaces the MH Series)
YMB-HW Series
(4-pipe, cooling and heating)
(Replaces the MH-HW Series)
YMBE Series
(2-pipe, cooling with electric heat)
(Replaces the MHE Series)
00781VIP
LD07966
(See page 3 for details)
Notes:
1. For proper operation, control valve must be normally closed.
2. Aquastats provided where required.
3. Electri

Summary of the content on the page No. 2

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) TABLE OF CONTENTS INSTALLATION INSTALLATION.................................................................................................................................................3-6 RECEIVING ...................................................................................................................................................3 STORAGE ...............................................................................................

Summary of the content on the page No. 3

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) INSTALLATION RECEIVING HORIZONTAL APPLICATION Material in this shipment has been inspected at the These fan coil units are factory assembled for horizon- factory and released to the transportation agency in tal left side down application without any modification good condition. When received, a visual inspection of required. To convert to horizontal right side down, all cartons should be made immediately. Any evidence remove horizontal drain pan a

Summary of the content on the page No. 4

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) INSTALLATION INSTALLATION � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � FIG. 2 – YMBE WIRING CONNECTIONS, FIG. 3 – YMBE WIRING CONNECTIONS, 25 KW 15 & 20 KW � � � � � � � � � � � � � � � � � � � � � � � � �

Summary of the content on the page No. 5

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) INSTALLATION INSTALLATION YMB, YMB-HW: YMBE: 1) Separate cooling and heating coils (4 row cooling 1) Factory installed electric heat coil) 2) 208/240 volt Motor 2) 120V multi-speed motor. 3) 240/24 transformer 3) Vertical / Horizontal drain pan (right-to left and left-to 4) Circuit breaker disconnect (above 10 kW) right airflow) 5) Manual air vent 4) Manual air vent 6) Throwaway filter 5) Throw away filter 7) Vertical / Horizontal drain pan (right-

Summary of the content on the page No. 6

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) INSTALLATION PIPING • Heat can only be applied to the cup of the valve body for a min i mal time before damage occurs The supply and return piping must be adequately sized (even with the use of wet rags. to meet the design water flow requirements as specified • Avoid rapid quenching of solder joints, as this for the specific installation (see table 3 for connection sizes). All chilled water piping must be insulated to will produce joints of

Summary of the content on the page No. 7

FORM 115.20-NOM4 (105) FORM 115.20-NOM4 (105) INSTALLATION FAN COILS START-UP CHECKLIST INSTALL CHECKLIST  Equipment received as ordered.  Unit checked for damage interior and exterior.  Make sure all ductwork is complete and available for full air flow.  Unit installed level to ensure proper drainage and operation.  Unit installed with proper clearances.  Ensure condensate water will drain toward the drain connection. An overflow drain may be required as a ba

Summary of the content on the page No. 8

MAINTENANCE MOTOR The blower motor should be cleaned annually and if it Divide the total number of units on the job into six has oiling ports, it should be oiled with a good grade equal groups. Each week inspect, clean or replace of SAE 20 oil. Normally a few drops of oil in each the filters in each group, in rotation. This insures bearing is sufficient. a uniform servicing interval. The interval may be lengthened or shortened as determined by experience. If inspection shows only the


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21