York 12 user manual

User manual for the device York 12

Device: York 12
Category: Air Conditioner
Manufacturer: York
Size: 0.27 MB
Added : 5/22/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York 12. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York 12.

For your convenience

If looking through the York 12 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York 12 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York 12 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York 12 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York 12 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York 12. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION OUTDOOR SPLIT-SYSTEM
AIR CONDITIONER
INSTRUCTION
MODELS: 10, 12, 13 AND 14 SEER
1 PHASE - 1.5 TO 5 TONS
TABLE OF CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHECK ELECTRICAL POWER SUPPLY . . . . . . . . . 2
SELECTING EQUIPMENT LOCATION

Summary of the content on the page No. 2

035-13606-003 Rev. A (202) GENERAL INFORMATION These outdoor units are designed to be connected to a matching UPG indoor coil with sweat connection lines. These units are factory charged with refrigerant for a matching The manufacturer is not responsible for the per- indoor coil plus 15 feet of field supplied line. The outside unit formance of a mismatched system. The outdoor is designed to be placed alongside or at the back of the unit must be installed with a compatible indoor home, remote fro

Summary of the content on the page No. 3

035-13606-003 Rev. A (202) A minimum clearance of 18 inches is required for service at Provide ample clearance from shrubs to allow adequate air to the control panel and compressor compartments access. A pass across the outdoor coil without leaves or branches 10 inch clearance is required for the air inlet to the outdoor being pulled into the coil. coil around the perimeter of the unit. The air discharge of the Consideration should be given to the distance and routing of unit requires a 60 inch

Summary of the content on the page No. 4

035-13606-003 Rev. A (202) Use only ACR grade copper tubing and keep ends sealed INSTALLATION until joints are made. OUTDOOR UNIT The correct diameters of the refrigerant lines are listed in the After the site has been selected, a solid base pad that will not Tabular Data Sheet. shift or settle should be provided. The base pad should not For best performance, select routing of refrigerant lines for come in contact with the foundation or side of the structure minimum distance and fewest number of

Summary of the content on the page No. 5

035-13606-003 Rev. A (202) When recovering refrigerant from a system, with a burnout, RE-ASSEMBLING, BRAZING AND CLEANING OF follow a safe procedure due to possible contamination. JOINT CONNECTIONS Avoid getting the refrigerant in the eyes or on the When using hard solder, an inert gas such as dry skin. nitrogen must be introduced and permitted to flow through tubing during brazing to displace air Contaminated refrigerant must be recovered and returned to and prevent oxidation. the local refrig

Summary of the content on the page No. 6

035-13606-003 Rev. A (202) ELECTRICAL WIRING REFRIGERANT VALVE OPERATION To prevent electrical shock, open remote discon- All outdoor units are shipped with the service nect so electrical supply to outdoor unit is shut valves in the closed position. After installation of off. Contactor does not open both sides of the the refrigerant and proper evacuation, make sure 208/230 volt electrical circuit. that all valves are in the open position and that the caps are securely tightened before turning P

Summary of the content on the page No. 7

035-13606-003 Rev. A (202) LOW VOLTAGE 1. Route the low voltage cable through the fingered bush- ing in the low voltage junction box. See Figures 9, 10 & Control wiring may vary depending upon the type of thermo- 11. stat and furnace being connected. 2. Using wire nuts, connect the low voltage wiring within the Low voltage wiring diagrams can be found with the furnace or low voltage box. air conditioning blower package installation instructions. 3. A minimum of 19 AWG wire must be used in conne

Summary of the content on the page No. 8

035-13606-003 Rev. A (202) E ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING POWER WIRING 208/230-1-60 CONTROL WIRING 230-1-50 24 VOLT CONTROL WIRING FACTORY WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) FURNACE OR AIR HANDLER TERMINAL BLOCK CY R G W * TERMINAL W IS ONLY REQUIRED ON SYSTEMS CONTACTOR WITH HEAT. TERMINALS * GND. COIL YR G W LUG ROOM THERMOSTAT CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. FIGURE 5 :

Summary of the content on the page No. 9

035-13606-003 Rev. A (202) Table 3: SUPERHEAT VALUE INDOOR WB OUTDOOR DB °F 1 °F 55 60 65 70 75 80 85 90 95 100 105 110 115 50 9 7 52 12 10 6 54 14 12 10 7 56 17 15 14 10 6 58 20 18 16 13 9 5 60 23 21 19 16 12 8 6 62 26 24 22 19 16 12 8 5 64 29 27 24 21 18 15 11 9 6 66 32 31 30 24 23 18 15 11 9 6 68 35 33 30 27 24 21 19 16 14 12 9 6 70 35 33 30 28 25 22 20 18 15 13 11 8 72 35 33 30 28 26 24 20 20 17 15 14 74 34 31 30 27 25 23 22 20 18 76 35 33 31 29 27 26 25 23 1. Evaporator Entering Air °F Tabl

Summary of the content on the page No. 10

035-13606-003 Rev. A (202) 3. Measure and record the suction pressure at the suction 6. Is air filter installed and clean? service valve port. 7. Is the blower motor speed set correctly? 4. Using Table 4, note the superheat value corresponding IMPORTANT - Installer should place unit data sheet and to the intersection of the indoor wet bulb and the outdoor installation instructions in customer packet and give to home dry bulb. owner after installation is complete. 5. With the superheat value obta

Summary of the content on the page No. 11

035-13606-003 Rev. A (202) SERVICE RECORDS Unitary Products Group 11

Summary of the content on the page No. 12

Subject to change without notice. Printed in U.S.A. 035-13606-003 Rev. A (202) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 035-13606-002, 550.46-N1Y (199) Unitary 5005 Norman Products York OK Group Drive 73069


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21