York 035-18843-000-a-0402 user manual

User manual for the device York 035-18843-000-a-0402

Device: York 035-18843-000-a-0402
Category: Air Conditioner
Manufacturer: York
Size: 0.22 MB
Added : 5/22/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York 035-18843-000-a-0402. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York 035-18843-000-a-0402.

For your convenience

If looking through the York 035-18843-000-a-0402 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York 035-18843-000-a-0402 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York 035-18843-000-a-0402 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York 035-18843-000-a-0402 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York 035-18843-000-a-0402 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York 035-18843-000-a-0402. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


CONTENTS
USER’S, MAINTENANCE
SAFETY INFORMATION
FORYOURSAFETY. .. .................... 2
and
SYSTEMOPERATION .... ... ... ... ... .. 2
THERMOSTATS . ......................... 2
INTERMITTENT IGNITIONDEVICE .......... 2
SERVICE INFORMATION
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . 3
TOSHUTDOWNTHEFURNACE: ........... 3
TO LIGHT THE FURNACE:. . . . . . . . . . . . . . . . . . 3
MANUAL
VENT SAFETY SYSTEM: . . . . . . . . . . . . . . . . . . . 3
100% SHUT OFF: ......................... 3

Summary of the content on the page No. 2

035-18843-000-A-0402 SAFETY INFORMATION SYSTEM OPERATION FORYOURSAFETY THERMOSTATS  Make sure that the furnace area is clear and free of Set your thermostat for either heating or cooling then set it for the desired temperature. DO NOT MOVE THE combustible materials, gasoline and other flamma- THERMOSTAT RAPIDLY ON AND OFF, OR BACK ble vapors and liquids. AND FORTH FROM HEAT TO COOL. THIS COULD DAMAGE YOUR EQUIPMENT.  Be sure the furnace is free and clear of insulating material. Examine the fur

Summary of the content on the page No. 3

035-18843-000-A-0402 When the room thermostat is satisfied, the electrical VENT SAFETY SYSTEM: circuit to the gas valve is opened, closing off both main This gas furnace is equipped with an automatic reset burner and pilot gas simultaneously. If the pilot burner high temperature sensor or rollout switch which in the should fail to light, contact your heating contractor or unlikely event of a sustained main burner flame rollout gas utility for service to insure that proper operating will shut off

Summary of the content on the page No. 4

035-18843-000-A-0402 If the furnace continues to lock out, a qualified service bustion air inlets or vent outlets on your unit. These technician should be called to determine the cause of provide air for combustion and ventilation. Adequate air the problem. is important to the safe and proper operation of the unit. HEATING SYSTEM INSPECTION It is the owner's responsibility to insure that an annual ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD inspection of the entire heating portion of the unit is

Summary of the content on the page No. 5

035-18843-000-A-0402 mary air shutters to give a distinct, sharp blue flame as 10.After brushing is complete, blow all brushed areas explained under BURNER AIR SHUTTER ADJUST- with air or nitrogen. Vacuum as needed. MENT. If it is not possible to adjust for the proper flame, the burners may need cleaning. 11.Replace parts in the order they were removed in Steps 1 thru 5. CLEANING BURNERS 12.When replacing the center and top of the flue collec- Remove them from the furnace as explained in tor box

Summary of the content on the page No. 6

035-18843-000-A-0402 To install the filters, remove the filter access panel located to the left of the condensate drain connection as showninFigure5. INDOOR COIL (2) 14" X 20" FILTERS NOTE: Filters must be installed with “Air Flow” arrows CONDENSATE DRAIN pointing inward -- toward the indoor coil. In the CONNECTION (1) 14" X 25" event the spacers in the filter section are FILTERS removed, they must be reinstalled in their origi- nal position. 3 - 6 TON UNIT Slide filters all the way into the fil

Summary of the content on the page No. 7

035-18843-000-A-0402 CONDENSER COIL REGISTERS An annual check and cleaning, if necessary, of the out- Supply and return air registers must be open when the door coil should be done. Cleaning should be as often unit is in operation. Obstructions must not be allowed as necessary to keep the coil clean. Clean any debris to block airflow in or out of the registers. and dirt from the outside coil face with a brush being careful not to damage the fins. If extremely dirty, a hose TROUBLESHOOTING canbe

Summary of the content on the page No. 8

REPLACEMENT PARTS OWNER please have your installer fill in the following information immediately after unit has been installed and properly operating. Installed by____________________________________________________________________________________________ Installer’s Address ______________________________________________________________________________________ Installation Date ________________________________________________________________________________________ Owner’s Name _________________


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21