York FAN COIL YVF/YVS user manual

User manual for the device York FAN COIL YVF/YVS

Device: York FAN COIL YVF/YVS
Category: Air Conditioner
Manufacturer: York
Size: 0.83 MB
Added : 6/16/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York FAN COIL YVF/YVS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York FAN COIL YVF/YVS.

For your convenience

If looking through the York FAN COIL YVF/YVS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York FAN COIL YVF/YVS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York FAN COIL YVF/YVS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York FAN COIL YVF/YVS User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York FAN COIL YVF/YVS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York FAN COIL YVF/YVS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

FAN COIL
AIR CONDITIONERS
Supersedes: Form 115.20-NOM3 (105) Form 115.20-NOM3 (1006)
INSTALLATION, OPERATION, & MAINTENANCE
MODEL YVC -Vertical Concealed Model
The YVC model fan coil is designed to be furred into the
wall where the supply and return or both are connected
YVC
to short runs of ductwork. These units are often used
for perimeter heating and cooling of offices, corridors,
hospitals, apartments, hotels, and other multi-room
buildings.
00563VIPa
MODEL YVS I YVF -Vertical Cabinet Mo

Summary of the content on the page No. 2

FORM 115.20-NOM3 (1006) TABLE OF CONTENTS INSTALLATION ...............................................................................................................................................3-10 RECEIVING ...................................................................................................................................................3 STORAGE ..................................................................................................................................

Summary of the content on the page No. 3

FORM 115.20-NOM3 (1006) INSTALLATION RECEIVING 1. Pull firmly on the lower cabinet door (each side) until the cabinet releases from its friction fastener. Material in this shipment has been inspected at the 2. Proceed to lift the door assembly straight up and factory and released to the transportation agency in off the cabinet frame. good condition. When received, a visual inspection of all cartons should be made immediately. Any evidence of rough handling or apparent damage should be not

Summary of the content on the page No. 4

FORM 115.20-NOM3 (1006) INSTALLATION WIRING 3. Mount the unit in its permanent location; making All wiring must comply with the local and national code sure it is level to insure proper drainage requirements. Units are provided with wiring diagrams and operation. 2 – ½” holes have been provided on and nameplate data to provide information required for each end of the unit for securing the unit to the wall necessary field wiring. studs. For power wiring a control box is provide

Summary of the content on the page No. 5

FORM 115.20-NOM3 (1006) INSTALLATION 4-PIPE HEAT / COOL T B 3 - 3 T B 2 - 5 T B 3 - 3 T B 2 - 5 L 1 O N O F F M E D H I L O M E D O F F H E A T C O O L H I L O H E A T C O O L H E A T C O O L T B 1 - 1 T B 1 - 2 T B 2 - 4 T B 1 - 4 T B 2 - 3 T B 2 - 1 T B 3 - 1 T B 3 - 2 T B 2 - 2 T B 1 - 2 T B 2 - 3 T B 2 - 4 T B 1 - 4 T B 1 - 1 T B 3 - 1 T B 3 - 2 T B 2 - 1 T B 2 - 2 L ( L 1 ) P O W E R L ( L 1 ) P O W E R N ( L 2 ) S U P P L Y N ( L 2 ) S U P P L Y G R D G R D 3 2 4 1 T H E R M I S T O R 4 3

Summary of the content on the page No. 6

FORM 115.20-NOM3 (1006) INSTALLATION 6. Avoid rapid quenching of solder joints, as this will DRAIN PIPING produce joints of inferior quality. Drain line installation must adhere to all code requirements. 7. The valve package will not support the weight of The plastic auxiliary drain pan is to be located under the the connecting pipes. All pipes, which are connected coil/valve connections supported by its mounting bracket. to the units, must be completely supported prior to Make sure drain p

Summary of the content on the page No. 7

FORM 115.20-NOM3 (1006) INSTALLATION PLASTIC DISCHARGE CONTROL ACCESS GRILLE DOOR TOP LH RH A GENERAL DIMENSIONS SIZE MODEL 3 4 6 8 10 12 FRONT DIM "A" 43 51 59 67 75 83 RETURN AIR OPENING 1/2" PERMANENT LEFT HAND UNIT SHOWN FILTER REMOVABLE THRU RETURN AIR OPENING END END 8-1/8 8-1/8 9-1/4 1/2 9-1/4 1/2 2-3/8 1/2 DIA. MTG. HOLES 2 EACH SIDE BACK 25 19-3/8 27-5/8 19 5/16 DIA. MTG. HOLES 2 EACH SIDE 9 3-3/4 3-3/4 16 4-1/2 4-1/2 7-1/4* 5 7-7/8 7-7/8 5-1/8 OPTIONAL BACK FRESH AIR INTAKE SECOND

Summary of the content on the page No. 8

FORM 115.20-NOM3 (1006) INSTALLATION TOP SUPPLY AIR OPENING SECONDARY CONTROL BOX PLASTIC DRAIN PAN 0.84 O.D. FOR 3/4" PVC PIPE FRONT ACCESS PANEL FRONT END 1" SUPPLY DUCT A 9-1/4 COLLAR 5 5 B 2 5 1/2 DIA. MTG 6-5/8 HOLES 2 EACH SIDE SUPPLY & RETURN WATER 24-1/2 CONNECTIONS 19-3/8 7-1/4* 5-1/8 3 RETURN AIR OPENING 8 7/8 C 7/8 1/2" PERMANENT FILTER REMOVABLE THRU D RETURN AIR OPENING (MTG. HOLES) 1-7/8 1-7/8 E C L (RIGHT HAND UNIT SHOWN) *DIMENSIONS VARY FOR UNITS 2-1/2 WITH NON STAN

Summary of the content on the page No. 9

FORM 115.20-NOM3 (1006) INSTALLATION TOP SECONDARY PLASTIC DRAIN CONTROL BOX PAN 0.84 O.D. FOR 3/4" PVC PIPE FRONT A 5-1/4 1/2 DIA. MTG END HOLES 6-5/8 2 EACH SIDE SUPPLY & RETURN WATER CONNECTIONS 24-1/2 22-3/8 7-1/4* 5-1/8 RETURN AIR OPENING 3 8 7/8 C 7/8 1/2" PERMANENT FILTER D REMOVABLE THRU (MTG. HOLES) RETURN AIR OPENING 1-7/8 E 1-7/8 (RIGHT HAND UNIT SHOWN) A Hand of unit determined by ALL DIMENSIONS ARE IN INCHES *DIMENSIONS VARY FOR UNITS cooling coil connection when WITH

Summary of the content on the page No. 10

FORM 115.20-NOM3 (1006) INSTALLATION WIDTH 1/2 DIA. MTG HOLES 2 EACH SIDE SUPPLY & RETURN WATER CONNECTIONS HEIGHT (RIGHT (RIGHT HAND UNIT SHO HAND UNIT SHOWN) WN) RETURN AIR OPENING A MODEL DRYWALL CUTOUT DIMENSIONS MODEL HEIGHT WIDTH MINIMUM HEIGHT ABOVE FLOOR (A) 3YWC 28" 42" 6" 4YWC 28 50" 6" 6YWC 28 58" 6" 8YWC 28 68" 6" 10YWC 28 74" 6" 12YWC 28 82" 6" FIG. 10 - YWC FAN COIL INSTALLATION LOCATION DIMENSIONS 10 YORK INTERNATIONAL

Summary of the content on the page No. 11

FORM 115.20-NOM3 (1006) INSTALLATION FAN COILS START - UP CHECKLIST INSTALL CHECKLIST ❑ Equipment received as ordered. ❑ Unit checked for damage interior and exterior. ❑ Make sure all ductwork is complete and available for full air flow. ❑ Unit installed level to ensure proper drainage and operation. ❑ Unit installed with proper clearances. ❑ Ensure condensate water will drain toward the drain connection. An overflow drain may be required as a back up to a clogged primary drain. ❑ Check th

Summary of the content on the page No. 12

MAINTENANCE MOTOR The intervals at which filters require replacement depend on local conditions. The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of Because of dust and lint in the room, room-air filters load SAE 20 oil. Normally a few drops of oil in each bearing up much more rapidly than outdoor-air filters. Under is sufficient. normal conditions, the room air filter requires cleaning every six to eight weeks. If motor service is


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21