York PREDATOR R-410A user manual

User manual for the device York PREDATOR R-410A

Device: York PREDATOR R-410A
Category: Air Conditioner
Manufacturer: York
Size: 10.91 MB
Added : 6/16/2014
Number of pages: 128
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York PREDATOR R-410A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York PREDATOR R-410A.

For your convenience

If looking through the York PREDATOR R-410A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York PREDATOR R-410A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York PREDATOR R-410A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York PREDATOR R-410A User manual - Online PDF
Advertisement
« Page 1 of 128 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York PREDATOR R-410A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York PREDATOR R-410A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

246824-YTG-G-1208
 
Description
TECHNICAL GUIDE
ASHRAE 90.1 COMPLIANT

® ®
YORK Predator units are convertible single packages with a
common footprint cabinet and common roof curb for all 6-1/2
through 12-1/2 ton models. All units have two compressors with
independent refrigeration circuits to provide 2 stages of cooling.
The units were designed for light commercial applications and
can be easily installed on a roof curb, slab, or frame.
®
All Predator units are self-contained and assemb

Summary of the content on the page No. 2

246824-YTG-G-1208 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

246824-YTG-G-1208 Heat Pump Simplicity® Control board w/screw connec- tors for T-stat wiring and network connection Disconnect location Filter access Terminal block Filter drier (solid core) (optional disconnect switch) (2” throw-away) for hi-voltage connection Condenser Second Model section Nameplate Inside Control Door Slide-out motor and blower assembly for Dual stage cool- easy adjustment and ing for maximum service. comfort (7-1/2 - 12-1/2 Only) Compressor #2 Access (High-Eff Co

Summary of the content on the page No. 4

246824-YTG-G-1208 Nomenclature ® 6.5-12.5 Ton York Model Number Nomenclature Z H 090 N10 A 2 A AA 4 0 1 2 4 A Product Category Product Style Z = A/C, Single Pkg., R-410A A = Style A X = HP, Single Pkg., R-410A B = Style B C = Style C Product Identifier Configuration Options (not required for all units) H = 11.0+ EER A/C These four digits will not be assigned until a quote is requested, or an order placed. P = 11.0 EER HP SS Drain Pan R = Reheat CPC Controller, DFS, APS Johnson Controller UNT 112

Summary of the content on the page No. 5

246824-YTG-G-1208 pressure switches. Internal compressor protection is Features and Benefits standard on all compressors. Crankcase heaters are Standard Features standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are • High Efficiency – High efficiency units reach as high as standard on units with scroll compressors. This accessory 11.5 EER. Gas/electric units have electronic spark ignition monitors the incoming power to the unit and

Summary of the content on the page No. 6

246824-YTG-G-1208 flash an alarm code on the control board LED. Each less than the setpoint of the economizer logic module. See high and low-pressure switch alarm as well as each economizer options section to determine the correct freezestat alarm has its own flash code. The control economizer for your application. board saves the five most recent alarms in memory, • Downflow Economizer - (With barometric relief) - and these alarms can be reviewed at any time. The economizer is provided

Summary of the content on the page No. 7

246824-YTG-G-1208 • Motorized Outdoor Air Damper - The motorized outdoor • Dirty Filter Switch - This kit includes a differential air damper includes a slide-in/plug-in damper assembly pressure switch that energizes the fault light on the unit with an outdoor air hood and filters. The outdoor air thermostat, indicating that there is an abnormally high dampers open to the preset position when the indoor fan pressure drop across the filters. Factory installed option or motor is energized. The

Summary of the content on the page No. 8

246824-YTG-G-1208 • CPC BAS Control - The Computer Process Controls • Dual Enthalpy Control, Accessory - This kit contains Model 810-3060 ARTC Advanced Rooftop building the required components to convert a single enthalpy automation system controller is factory installed. Includes economizer to dual enthalpy. supply air sensor, return air sensor, dirty filter indicator • Barometric Relief Damper - Zero to 100% capacity switch and air proving switch. barometric relief dampers for use with ho

Summary of the content on the page No. 9

246824-YTG-G-1208 include an adapter panel for easy installation of the • Permanent Filters - Permanent filters are available. electric heaters. Necessary hardware and connectors are • Roof Curbs - The roof curbs have insulated decks and are included with the heaters. All heaters are intended for shipped disassembled The roof curbs are available in 8” and single point power supply. 14” heights. For applications with security concerns, burglar • Low Limit / Compressor Lockout Kit bars are a

Summary of the content on the page No. 10

246824-YTG-G-1208 Accessories (Continued) Part Number Description 2EC04700924 Dual Enthalpy Control (Use with Single Enthalpy Economizer) 1EH0407 Hood Kit, Downflow Economizer (Included with all Downflow Economizers) 1RD0411 Barometric Relief Kit, Ductmount for Horizontal Application (Incl. Damper & Hood) 1EH0408 Barometric Relief Kit, Ductmount for Horizontal Application w/Power Exhaust (Incl. Damper & Hood) 1EH0409 Barometric Relief / Hood Kit, for Field Installed Slab Econ. w/o ERV (Incl. Bar

Summary of the content on the page No. 11

246824-YTG-G-1208 accessible through hinged access door. Fan performance c. Accessible service gage connections on both suction measuring ports shall be provided on the outside of the cabinet and discharge lines to charge, evacuate, and measure to allow accurate air measurements of evaporator fan refrigerant pressure during any necessary servicing or performance without removing panels or creating bypass of the troubleshooting, without losing charge. coils. Condensate pan shall be slide out

Summary of the content on the page No. 12

246824-YTG-G-1208 d. Flame proving controls. Unit shall have two independent maximum leakage rate for the outdoor air intake dampers st nd stages of capacity (60% 1 stage, 100% 2 stage). shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A ELECTRIC HEATING SECTION (IF EQUIPPED) unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the An electric heating section, with nickel chro

Summary of the content on the page No. 13

246824-YTG-G-1208 • PROPANE CONVERSION KIT – Contains new orifices Anytime there is a call for 2 stages of cooling, the unit will not and gas valve springs to convert from natural to L.P. gas. operate in the reheat mode, even if there is a call for dehumidi- fication at "HUM". • 60ºF GAS HEAT KIT – Provides an electric heat kit for the gas compartment for use in extreme low ambient The unit will not operate in the reheat mode if there is any call conditions. for heating. • ECONOMIZER (Downflo

Summary of the content on the page No. 14

246824-YTG-G-1208 Reheat Control Board R Y1 P4 Y2 K1 G W1 K2 W2 OCC K4 C K3 COM ` P6 P5 P3 HGRR HGR HUM MODE DEHUMIDISTAT SELECTION HARNESS JUMPER CONNECTION 14 Johnson Controls Unitary Products

Summary of the content on the page No. 15

246824-YTG-G-1208 Physical Data ZH078-150 Physical Data Models Component ZH078 ZH090 ZH102 ZH120 ZH150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 79000 93000 106000 126000 156000 ARI net capacity (Btu) 76000 90000 102000 122000 150000 EER 11.4 11.4 11.5 11.5 11.2 SEER - ---- IPLV 12.7 12.4 12.4 12.1 12.7 Nominal CFM 2600 3000 3400 4000 5000 System power (KW) 6.67 7.90 8.87 10.61 13.40 Refrigerant type R-410a R-410a R-410a R-410a R-410a Refrig

Summary of the content on the page No. 16

246824-YTG-G-1208 ZH078-150 Physical Data (Continued) Models Component ZH078 ZH090 ZH102 ZH120 ZH150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 Quantity 2 2 2 2 4 Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 Number of motors 2 2 2 2 4 Motor HP each 1/3 1/3 3/4 3/4 1/3 RPM 850 850 1110 1110 850 Nominal total CFM 6800 6800 8800 8800 14000 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 1 1 Fan Size (Inch) 12 x 12 12 x 12 15 x

Summary of the content on the page No. 17

246824-YTG-G-1208 ZR078-150 Physical Data Models Component ZR078 ZR090 ZR102 ZR120 ZR150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 80000 91000 106000 125000 156000 ARI net capacity (Btu) 78000 88000 102000 120000 150000 EER 11.2 11.2 11.2 11.2 11.2 SEER - ---- IPLV 13.0 12.3 12.3 12.3 12.7 Nominal CFM 2600 3000 3400 4000 5000 System power (KW) 6.96 7.86 9.11 10.71 13.39 Refrigerant type R-410a R-410a R-410a R-410a R-410a Refrigerant charge (

Summary of the content on the page No. 18

246824-YTG-G-1208 ZR078-150 Physical Data (Continued) Models Component ZR078 ZR090 ZR102 ZR120 ZR150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 REHEAT COIL DATA Face area (Sq. Ft.) 6.66 6.66 10 10 10 Rows 22 222 Fins per inch 13 13 13 13 13 Tube diameter (in.) 3/8 3/8 3/8 3/8 3/8 CONDENSER FAN DATA Quantity 2 2 2 2 4 Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 Number of motors 2 2 2 2 4 Motor HP each 1/3 1/3 1/3 1/3

Summary of the content on the page No. 19

246824-YTG-G-1208 XP078-150 Physical Data Models Component XP078 XP090 XP102 XP120 XP150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 ARI COOLING PERFORMANCE Gross Capacity @ ARI A point (Btu) 80000 95000 104000 122000 156000 ARI net capacity (Btu) 78000 92000 100000 118000 150000 EER 11.0 11.0 11.0 11.0 11.0 SEER - ---- IPLV 12.4 12.4 12.4 12.4 11.9 Nominal CFM 2600 3000 3400 4000 5000 System power (KW) 7.10 8.35 9.10 10.70 13.60 Refrigerant type R-410a R-410a R-410a R-410a R-410a Refrigerant charge (

Summary of the content on the page No. 20

246824-YTG-G-1208 XP078-150 Physical Data (Continued) Models Component XP078 XP090 XP102 XP120 XP150 Nominal Tonnage 6.5 7.5 8.5 10 12.5 REHEAT COIL DATA Quantity 2 2 2 2 4 Fan diameter (Inch) 24 24 24 24 24 Type Prop Prop Prop Prop Prop Drive type Direct Direct Direct Direct Direct No. speeds 1 1 1 1 1 Number of motors 2 2 2 2 4 Motor HP each 1/3 1/3 1/3 1/3 1/3 RPM 850 850 850 850 850 Nominal total CFM 6800 6800 6800 6800 14000 CONDENSER FAN DATA Quantity 2 2 2 2 4 Fan diameter (Inch) 24 24 24


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21