Summary of the content on the page No. 1 
                    
                         
 
 
 
 
ALARM MONITOR 
MODEL AM-255 
 
OPERATING AND SERVICE MANUAL 
 
 
Version 1.01z 
December 20,2004 
 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Summary of the content on the page No. 2 
                    
                            AM-255  TABLE OF CONTENTS  1. INTRODUCTION..................................................................................................................... 1  1.1.  SCOPE AND PURPOSE OF MANUAL.................................................................... 1  1.2.  GENERAL DESCRIPTION ....................................................................................... 1  1.3.  SAFETY PRECAUTIONS ......................................................................................
                    
                    Summary of the content on the page No. 3 
                    
                            APPENDIX .................................................................................................................................. 19  A. WARRANTY.......................................................................................................................... 19  B. GLOSSARY ............................................................................................................................ 20  C. FORMULAS .............................................................
                    
                    Summary of the content on the page No. 4 
                    
                        1. INTRODUCTION  page 1    1. INTRODUCTION    1.1.  SCOPE AND PURPOSE OF MANUAL    This manual is designed to enable operating and service personnel to properly operate and care  for the AM-255.  Since applications are necessarily site-specific, operation procedures are given  in general terms.  Service and repair are covered to the board level.  Anything more complex  than this requires that the instrument or assembly be returned to TSA.    1.2.  GENERAL DESCRIPTION    The TSA Model AM-255 Alar
                    
                    Summary of the content on the page No. 5 
                    
                        1. INTRODUCTION  page 2    1.4.  SPECIFICATIONS    Display:  4 alarm indicator LEDs per pillar being monitored;       One systems ready LED, one power on LED    Power:   Internal:  12 volt, 7Ah sealed lead-acid battery pack    Relay Power:  Maximum 0.6 amp at 120Vac    Battery life:  More than 24 hours of normal operation    Controls:  Momentary contact alarm acknowledge switch, key lock switch,     and lamp test switch    Connectors:     Input:  One 4 pin, quick connect type terminal strip per 
                    
                    Summary of the content on the page No. 6 
                    
                        2. INSPECTION AND SET-UP  page 3    2. INSPECTION AND SETUP    The following procedures should allow on-site personnel to correctly install and set up the   AM-255 for normal operation.  Follow the procedures in the order given.  It is recommended that  a copy of the Initial Installation Set-Up Checklist (section 2.4.). be filled out after initial  installation and whenever the AM-255 is put into service after prolonged storage.    If necessary, consult TSA Systems for assistance in case of unus
                    
                    Summary of the content on the page No. 7 
                    
                        2. INSPECTION AND SET-UP  page 4    2.1.4.  Shipping:  Before returning the instrument for any reason, notify TSA Systems of the difficulty  encountered, giving the model and serial numbers of the equipment.  TSA will furnish specific  shipping instructions.    2.2.  SET-UP PROCEDURES    An Initial Setup Checklist is included at the end of this section.  It is recommended that a copy  of this be filled out when the AM-255 is first installed, and whenever it is put into service after  prolonged s
                    
                    Summary of the content on the page No. 8 
                    
                        2. INSPECTION AND SET-UP  page 5    2.2.3.  Connect the Positive Battery Cable:  The positive battery cable is disconnected for shipping, and must be connected to the positive   battery terminal.    2.2.4.  Power:  Plug the power cord into a standard 90 to 250Vac outlet.    2.2.5.  Toggle Power Switch:  There is a toggle power switch on the circuit board.  This switch must be turned on (away  from  the connector edge of the board).  The green power LED on the front panel will be  illuminated  to
                    
                    Summary of the content on the page No. 9 
                    
                        2. INSPECTION AND SET-UP  page 6    Connect the wires to the appropriate connections on the terminal strips.  The following tables  outline the connections.    SYSTEM #1  INPUT SIGNALS RELAY OUTPUTS  Signal Terminal Strip, Pin Signal Terminal Strip, Pin  Radiation Alarm J3-1 Radiation, C J4-1  High Background J3-2 Radiation, NC J4-2  Low Background J3-3 Radiation, NO J4-3  Tamper J3-4* High Background, C J4-4  Common J3-5 High Background, NC J4-5      High Background, NO J4-6    Low Background, 
                    
                    Summary of the content on the page No. 10 
                    
                        2. INSPECTION AND SET-UP  page 7      SYSTEM #2  INPUT SIGNALS  RELAY OUTPUTS  Signal Terminal Strip, Pin Signal Terminal Strip, Pin  Radiation Alarm J5-1 Radiation, C J2-1  High Background J5-2 Radiation, NC J2-2  Low Background J5-3 Radiation, NO J2-3  Tamper J5-4* High Background, C J2-4  Common J5-5 High Background, NC J2-5    High Background, NO J2-6    Low Background, C J2-7    Low Background, NC J2-8    Low Background, NO J2-9    Tamper, C J2-10    Tamper, NC J2-11    Tamper, NO J2-12    
                    
                    Summary of the content on the page No. 11 
                    
                        2. INSPECTION AND SET-UP  page 8    2.4.  INITIAL SETUP CHECKLIST    ___  Initial inspection done    ___  Cabling properly connected    ___  AC power available    ___  READY and POWER lamps go on when unit is plugged in    ___  ACKNOWLEDGE button operates correctly    ___  TEST function operates properly    ___  Alarm test    ___  All indicator lamps operate properly    ___  Sonalert sounds when alarm indicated    ___  Relays setup and operate correctly (if used)      Performed by: _____________
                    
                    Summary of the content on the page No. 12 
                    
                        3. OPERATING INSTRUCTIONS  page 9    3. OPERATING INSTRUCTIONS    3.1.  CONTROLS AND INDICATORS    The controls and indicators can be made to operate in several different ways.  How they operate  is controlled by the software installed.    The front panel contains the power LED, ready LED, alarm indicator LEDs, and the  acknowledge switch.  The power LED is on whenever the system has power.  The ready LED  shows that the system is clear of alarms and working properly.  The alarm indicator LEDs b
                    
                    Summary of the content on the page No. 13 
                    
                        3. OPERATING INSTRUCTIONS  page 10     Acknowledge:  This is a momentary contact pushbutton switch which clears the audio and visual  indication of alarm conditions.     Key Switch:  The key switch is used to clear alarm lamps or test relays during maintenance.     Test:  A momentary contact pushbutton switch used to test the lamps, LEDs, and  Relays.     Sonalert:  The Sonalert provides audible alarm.    3.2.  SUMMARY OF ALARM INDICATIONS    SUMMARY OF ALARM INDICATIONS The AM-255 provides  bot
                    
                    Summary of the content on the page No. 14 
                    
                        3. OPERATING INSTRUCTIONS  page 11    3.3.  OPERATION    During normal operation no operator intervention is needed.  If an alarm condition is indicated,  the AM-255 will sound an audible alarm and the panel lamps will indicate the nature of the  alarm so that proper action may be taken.    Pressing the test button will cause all the alarm lamps to flash, the ready LED to illuminate and  the audio alarm to sound.  If the key switch is in the normal position, it will energize the relays.  Model A
                    
                    Summary of the content on the page No. 15 
                    
                        4. THEORY OF OPERATION  page 12    4. THEORY OF OPERATION    The alarm monitor model AM-255 is a battery powered, remote monitor unit used with TSA’s  pedestrian and vehicle portal monitors.  The AM-255 provides both audible and visual alarm  indications for radiation alarms, low and high background alarms, and tamper conditions.   Parallel relay outputs are provided to permit interfacing with existing alarm systems.    Please reference the wiring/signal flow diagram drawings package provided wi
                    
                    Summary of the content on the page No. 16 
                    
                        4. THEORY OF OPERATION  page 13    4.2.  COMPONENTS    4.2.1.  AM-255 Board:  The AM-255 Board is the controller board for the system.  It receives information from the  system, and enables the appropriate lamps, relays, and the Sonalert.  All functions of the  AM-255 board are controlled by a Programmable Logic Device.    There is also a battery monitoring circuit on the board.  If the battery voltage drops below 10.5  Vdc the load disconnect will turn off the system power.  When the battery vo
                    
                    Summary of the content on the page No. 17 
                    
                        5. MAINTENANCE  page 14    5. MAINTENANCE    5.1.  MAINTENANCE PROCEDURES    The AM-255 has been designed for continuous use, and once initial installation has been  completed, little maintenance is required.  Periodic inspection is recommended to insure proper  functioning.  This should include (but is not limited to):    -  checking the alarm lamps and Sonalert with the TEST switch  -  performing an alarm test, High, Radiation, Low, Tamper  -  visual inspection for loose cables, wires, etc.   
                    
                    Summary of the content on the page No. 18 
                    
                        5. MAINTENANCE  page 15    5.2.  PERFORMANCE VERIFICATION CHECKLIST    ___  Repairs made (if any):  list component and type of repair:    ______________________________________________________________________________  ______________________________________________________________________________  ______________________________________________________________________________  ______________________________________________________________________________  __________________________________________
                    
                    Summary of the content on the page No. 19 
                    
                        6.  TROUBLESHOOTING  page 16    6. TROUBLESHOOTING    This guide is designed so that on-site personnel can service the AM-255 and effect necessary  minor repairs.  It covers procedures and parts down to the board level.  Any other problems  should be referred to factory authorized service personnel.  Unauthorized repair voids warranty.    When repairs are completed and the unit returned to operation, a copy of the Performance  Verification Checklist (section 5.2.) should be filled out and filed 
                    
                    Summary of the content on the page No. 20 
                    
                        6.  TROUBLESHOOTING  page 17    6.1.3.  Battery Charger:  The Battery Charger is wired directly into Molex connector to the AM-255 board. To disconnect,  the Molex pins must be removed from the housing by inserting a small screwdriver or sharp  pointed object into the slots in the housing and pressing down, while pulling gently on the wire.  The ac input plugs into the charger with a standard IEC connector.  To reinstall the battery  charger insert the pins into the Molex housing, and reconnect