Honeywell F100 user manual

User manual for the device Honeywell F100

Device: Honeywell F100
Category: Air Cleaner
Manufacturer: Honeywell
Size: 2.28 MB
Added : 4/25/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell F100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell F100.

For your convenience

If looking through the Honeywell F100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell F100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell F100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell F100 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell F100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell F100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GETTING
SPECIFICATIONS
MOUNTING
STARTED
APPENDICES
F100 Media Air Cleaner

PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
INCLUDED IN THIS BOX
Tools needed to install Enhanced Air Cleaner
Standard screwdriver


Phillips screwdriver
Metal cutter
Drill
Duct Sealant
Replacement Air Filters
Filter Size (in.) Part Number
12.5 x 20 FC100A1052
16 x 25 FC100A1029
16 x 20 FC100A1003
20 x 25 FC100A1037
20 x 20 FC100A1011
68-0239EF-05

Summary of the content on the page No. 2

Summary of the content on the page No. 3

GETTING MOUNTING SPECIFICATIONS STARTED F100 Media Air Cleaner What to Expect From Your Honeywell Choosing a Mounting Position ..................................6 Media Air Cleaner .....................................................2 Mounting the F100 Media Air Cleaner ......................9 When Installing this Product... .......................................2 Checkout .................................................................10 How it Works .......................................

Summary of the content on the page No. 4

What to Expect From Your Honeywell Media Air Cleaner Congratulations for selecting the Honeywell Media Air Cleaner for your home comfort system! The F100 Media Air Cleaner captures and removes a significant amount of the air-borne particles from the air circulated through the high-efficiency pleated media filter. The Media Air Cleaner easily mounts in any position within the return air duct of any gas, oil, and electric forced warm air furnaces and to compressor cooling up to 5 tons. Addition

Summary of the content on the page No. 5

GETTING STARTED Application Considerations The Honeywell F100 Media Air Cleaner is designed to work with gas, oil, and electric forced warm air furnaces and with compressor cooling. It can also be used with heat pumps if the filter is changed regularly to prevent excessive pressure drop. The F100 Media Air Cleaner is not recommended for applications where pressure drop may be critical. Models F100F Media Air Cleaner includes cabinet, access door and pleated media filter. F100B Media Air Clea

Summary of the content on the page No. 6

DUCT SIZE CHANGED GRADUALLY TO PREVENT TURBULENCE. Transitions 20 DEGREE EXPANSION PER SIDE PER For most efficient air cleaning, spread airflow evenly FITTING (4 IN. PER RUNNING FOOT [100 MM PER 300 LINEAR MM]) across the face of the media. If the duct is a different size than the media air filter cabinet, gradual transitions RETURN AIR are required. Follow these guidelines when fabricating: DUCT • Use gradual transitions to reduce air turbulence and increase efficiency. TRANSITION F

Summary of the content on the page No. 7

GETTING STARTED Important Installation Requirements Failure to comply with these requirements will result in voided warranty, improper installation, and service callbacks. Personal Safety • Wear safety glasses while installing the unit. • Do not cut into any air conditioning or electrical line. • Follow professional safety standards and all local codes for plumbing, electrical, and mechanical considerations. Before Mounting • Using the figure on the cover and the lists on the inside cover, ma

Summary of the content on the page No. 8

Choosing a Mounting Position The Media Air Cleaner mounts in any position within the return air duct, usually next to the furnace blower compartment, but the arrow on the cartridge must point in the same direction as the airflow. See Figs. 3-10 for proper location of the media air cleaner for a variety of furnace installations. NOTE: The media air cleaner cabinet is sturdy enough to easily support the weight of the furnace and evaporator coil. M939B M940B Fig. 1. Highboy furnace with side in

Summary of the content on the page No. 9

MOUNTING M942B M941A Fig. 3.Highboy furnace, with closet installation. Media air Fig. 4. Lowboy furnace, with media air cleaner cleaner is mounted vertically on furnace between mounted horizontally in return plenum just above furnace and louvered return air opening in closet door. furnace and opposite heating plenum. F100 Media Air Cleaner 68-0239EF—05 7

Summary of the content on the page No. 10

M943B M944B Fig. 5. Counterflow furnace, with media air cleaner Fig. 6. Central fan installation, with media air cleaner mounted horizontally in return duct or plenum just above mounted horizontally in central return duct. furnace. M945B M946B Fig. 7. Horizontal furnace, with media air filter mounted Fig. 8. Two or more media air cleaners used in a high vertically in return duct near furnace. capacity system. F100 Media Air Cleaner 68-0239EF—05 8 MOUNTING

Summary of the content on the page No. 11

MOUNTING Mounting the F100 Media Air Cleaner The following procedure describes a typical side installation on an existing highboy furnace (Fig. 1). Alternate procedures are noted as appropriate. Other changes in installation procedures may be necessary to complete your installation. NOTE: Before starting the installation, remove and discard the existing furnace filter (if used). Thoroughly clean the blower compartment. If possible, power vacuum the ductwork to remove accumulated dust in an o

Summary of the content on the page No. 12

Checkout Visually check the installation and make sure that: • Airflow is in the direction of the arrow on the media air filter cartridge. • Turning vanes and transitions, if used, are properly installed. • Joints in sheetmetal between media air filter and furnace are sealed. • All sheetmetal connections are complete. • Original furnace filter has been removed and blower compartment is cleaned. When you have verified that checkout has been completed: • Replace any access doors removed duri

Summary of the content on the page No. 13

SPECIFICATIONS Capacity And Pressure Drop Approvals Initial Pressure Drop: 0.23 in. wc at 492 fpm. Underwriters Laboratories, Inc.: Listed to UL 900, FILTER SIZE 20 X 25 16 X 25 Class 2. 20 X 20 16 X 20 0.500 Upgrade Path 1 0.400 The F100 uses the same cabinet as the F300 Electronic Air Cleaner. Upgrade may require installing 0.300 PRESSURE the cell key, electronic cells, protective screens and DROP 0.200 (IN. WC) installation and wiring of the power box, depending on 0.100 model. (Note th

Summary of the content on the page No. 14

Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com ® U.S. Registered Trademark. © 2011 Honeywell International Inc. 68-0239EF—05 M.S. 07-11 Printed in U.S.A.

Summary of the content on the page No. 15

POUR CARACTÉRISTIQUES MONTAGE COMMENCER TECHNIQUES Épurateur d’air à fibres F100 • PROFESSIONAL INSTALLATION GUIDE. • GUIDE D’INSTALLATION PROFESSIONNELLE. INCLUS DANS LA BOÎTE Outils requis pour installer l’épurateur d’air amélioré Tournevis normal Tournevis cruciforme Cisailles à tôle Perceuse Produit d’étanchéité de gaine Filtres à air de rechange Dimension du filtre (po) Référence de pièce 12,5 x 20 FC100A1052 16 x 25 FC100A1029 16 x 20 FC100A1003 20 x 25 FC100A1037 20 x 2

Summary of the content on the page No. 16

Summary of the content on the page No. 17

CARACTÉRISTIQUES POUR MONTAGE COMMENCER TECHNIQUES Épur ateur d’air à fibr es F100 À propos de l’épur ateur d’air à fibr es Sélection de la position de montage ........................6 F100 de Honeywell ...................................................2 Montage de l’épur ateur d’air à fibr es F100 ..............9 Lors de l’installation du produit... ...................................2 Vérification .............................................................10 Fonctionnement .............

Summary of the content on the page No. 18

À propos de l’épur ateur d’air à fibr es de Honeywell Félicitations pour votre choix de l’épurateur d’air à fibres Honeywell pour votre système de confort d’intérieur! L’épurateur d’air à fibres F100 capture et retire une quantité considérable de particules contenues dans l’air circulant par le filtre à fibres à plis haute efficacité. L’épurateur d’air à fibres se monte facilement dans toutes les positions dans la gaine d’air de retour de tout appareil de chauffage à gaz, mazout, électrique e

Summary of the content on the page No. 19

POUR COMMENCER Considérations relatives à l’application L’épurateur d’air à fibres F100 de Honeywell est conçu pour fonctionner avec les appareils de chauffage à gaz, mazout, électrique et air pulsé et les systèmes de refroidissement par compresseur. Il peut aussi être utilisé avec des thermopompes uniquement si le filtre est remplacé régulièrement pour éviter les chutes de pression excessives. L’épurateur d’air à fibres F100 n’est pas recommandé dans les applications pour lesquelles une ch

Summary of the content on the page No. 20

DIMENSION DE GAINE MODIFIÉE GRADUELLEMENT POUR Transitions ÉVITER LES TURBULENCES. EXPANSION DE 20° PAR CÔTÉ PAR RACCORD Pour un nettoyage de l’air optimal, le débit d’air doit (100 MM TOUS LES 300 MM LINÉAIRES [4 PO PAR PIED DE LONGUEUR]) passer uniformément sur la face du filtre. Si la taille de la gaine est différente de l’armoire du filtre à fibres, GAINE D’AIR DE RETOUR des transitions graduelles sont requises. Suivre ces instructions lors de la fabrication : • Utiliser des transitio


Alternative user manuals
# User manual Category Download
1 Honeywell 11500 User manual Air Cleaner 260
2 Honeywell 11255 User manual Air Cleaner 27
3 Honeywell 13350 User manual Air Cleaner 25
4 Honeywell 12500 User manual Air Cleaner 50
5 Honeywell 14500 User manual Air Cleaner 54
6 Honeywell 13500 User manual Air Cleaner 4
7 Honeywell 18150 Series User manual Air Cleaner 2
8 Honeywell 18150 User manual Air Cleaner 3
9 Honeywell 16200 User manual Air Cleaner 66
10 Honeywell 17000 User manual Air Cleaner 34
11 Honeywell 203365A User manual Air Cleaner 1
12 Honeywell 17005 User manual Air Cleaner 2
13 Honeywell 18155 User manual Air Cleaner 2
14 Honeywell 50100 User manual Air Cleaner 10
15 Honeywell 50200 User manual Air Cleaner 2
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9