Honeywell 68-0308EFS-03 user manual

User manual for the device Honeywell 68-0308EFS-03

Device: Honeywell 68-0308EFS-03
Category: Air Cleaner
Manufacturer: Honeywell
Size: 9.14 MB
Added : 4/25/2013
Number of pages: 96
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell 68-0308EFS-03. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell 68-0308EFS-03.

For your convenience

If looking through the Honeywell 68-0308EFS-03 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell 68-0308EFS-03 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell 68-0308EFS-03 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell 68-0308EFS-03 User manual - Online PDF
Advertisement
« Page 1 of 96 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell 68-0308EFS-03 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell 68-0308EFS-03. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GETTING OPERATION
MOUNTING WIRING APPENDICES
STARTED AND SERVICE
TrueCLEAN™ Enhanced Air Cleaner
Sizes: Air Handler 16x20, 20x20, 25x20 • Furnace 16x25 and 20x25

PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
GUÍA DE INSTALACIÓN PROFESIONAL.
INCLUDED IN THIS ENHANCED AIR CLEANER BOX
A1 A2 B C D E
F
J1 J2
I
G
K
H
68-0308EFS-03
M28898
Tools needed to install Enhanced Air Cleaner
A1 Door FH8000A

Standard screwdriver

Door FH8000F
A2

Phillips screwdriver

Cabi

Summary of the content on the page No. 2

Summary of the content on the page No. 3

GETTING OPERATION MOUNTING WIRING APPENDICES STARTED AND SERVICE TrueCLEAN™ Enhanced Air Cleaner GETTING STARTED WIRING What to Expect From Your Honeywell Before Wiring the Honeywell Enhanced Air TrueCLEAN™ Enhanced Air Cleaner ....................................2 Cleaner ..............................................................................14 How it Works ........................................................................2 Wiring the FH8000A (Air Handler) Honeywell Applicatio

Summary of the content on the page No. 4

What to Expect From Your Honeywell TrueCLEAN™ Enhanced Air Cleaner Congratulations for selecting the Honeywell TrueCLEAN™ Enhanced Air Cleaner for your home comfort system! The Honeywell Enhanced Air Cleaner is proven to remove and destroy airborne germs and allergens, including viruses, bacteria, and mold spores from air moving through the filter. The Honeywell Enhanced Air Cleaner is a cornerstone of Honeywell’s home comfort solutions for providing cleaner air in your home. The installer s

Summary of the content on the page No. 5

GETTING STARTED Application Considerations The Honeywell Enhanced Air Cleaner is designed for use in the return air duct of a forced air heating, cooling, and ventilation system. Models FH8000A1620, FH8000A2020 and FH8000A2520 are specifically designed for use in systems with an air handler. Models FH8000F1625 and FH8000F2025 are specifically designed for use in systems with a forced air furnace. The Honeywell Enhanced Air Cleaner is CSA certified for shock and electrical fire hazard only.

Summary of the content on the page No. 6

Application Considerations Electrical Power / Airflow Switch The Honeywell Enhanced Air Cleaner should only be powered when airflow is present. FH8000A – These models are designed for use with an air handler and are equipped with an airflow switch (see Fig. 1), which provides power only when the air handler blower is operating. These models are designed to be powered from a 208 to 230 VAC single phase power source. M28899 Fig. 1. Airflow Switch. FH8000F – The furnace control EAC terminals pro

Summary of the content on the page No. 7

GETTING STARTED Important Installation Requirements Failure to comply with these requirements will result in voided warranty, improper installation, and service callbacks. Personal Safety • Wear safety glasses while installing the unit. • Do not cut into any air conditioning or electrical line. • Follow professional safety standards and all local codes for plumbing, electrical, and mechanical considerations. Before Mounting • Using the figure on the cover and the lists on the inside cover, ma

Summary of the content on the page No. 8

Choosing a Mounting Method There are two Honeywell Enhanced Air Cleaner designs. One designed for air handlers and one designed for furnaces. Follow the installation instructions for the Air Cleaner model you have: Which Honeywell Enhanced Air Cleaner model do you have? Models FH8000A for air handlers: Models FH8000F for furnaces: These models are installed upstream of the air handler. These models are installed upstream of both the This will help keep the air handler clean. furnace and the ai

Summary of the content on the page No. 9

MOUNTING Mounting the FH8000A (Air Handler) Honeywell Enhanced Air Cleaner NOTE: For mounting a FH8000F model go to page 10. CAUTION: Personal Injury Hazard. Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, eye protections, and gloves when handling parts. STEP ONE: Identify the Mounting Location and Orientation a. Identify a mounting orientation for the Honeywell Enhanced Air Clea

Summary of the content on the page No. 10

Mounting the FH8000A (Air Handler) Honeywell Enhanced Air Cleaner STEP TWO: Mount Cabinet WARNING: Electrocution and Unit Damage Hazard. Failure to follow this warning could result in personal injury or death. Only a trained, experienced service person should install the Honeywell Enhanced Air Cleaner. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. 1. Be

Summary of the content on the page No. 11

MOUNTING Mounting the FH8000A (Air Handler) Honeywell Enhanced Air Cleaner e. Use return duct adapters provided to attach return ductwork (see Fig. 6). f. Seal seams with tape or caulking after the Honeywell Enhanced Air Cleaner cabinet has been secured. RETURN DUCT ADAPTORS NOTE: SLIP THE ADAPTOR S-CLEATS ONTO FLANGES ON THE RETURN DUCT SIDE. M28904 Fig. 6. Use of Return Duct Adapters for FH8000A. Before proceeding to Wiring on page 14: I mounted and secured the Honeywell Enhanced Air Cle

Summary of the content on the page No. 12

Mounting the FH8000F (Furnace) Honeywell Enhanced Air Cleaner NOTE: For mounting a FH8000A model go back to page 7. CAUTION: Personal Injury Hazard. Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. STEP ONE: Identify the Mounting Location and Orientation a. Identify a mounting orientation for the Honeywell Enhanced Air Cleaner in the return air duct

Summary of the content on the page No. 13

MOUNTING Mounting the FH8000F (Furnace) Honeywell Enhanced Air Cleaner NOTE: WHEN TRANSITIONING BEWTWEEN TWO DIFFERENT SIZED COMPONENTS (FURNACE AND AIR CLEANER), THE MINIMUM TRANSITION ANGLE AT THE LARGER OF THE TWO COMPONENTS MUST BE NO LESS THAN 45 DEGREES. AIRFLOW AIRFLOW AIRFLOW AIRFLOW DOWNFLOW 14” FURNACE UPFLOW 14” FURNACE HORIZONTAL 14” FURNACE UPFLOW FURNACE WITH TOP MOUNT WITH BOTTOM MOUNT WITH SIDE MOUNT AIRFLOW AIRFLOW AIRFLOW AIRFLOW PLENUM BOX DOWNFLOW 24” FURNACE UPF

Summary of the content on the page No. 14

Mounting the FH8000F (Furnace) Honeywell Enhanced Air Cleaner STEP TWO: Mount Cabinet WARNING: Electrocution and Unit Damage Hazard. Failure to follow this warning could result in personal injury or death. Only a trained, experienced service person should install the Honeywell Enhanced Air Cleaner. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. 1. Before

Summary of the content on the page No. 15

MOUNTING Mounting the FH8000F (Furnace) Honeywell Enhanced Air Cleaner f. Return air duct adapters have been included for installer convenience. They should be used to connect the upstream side of the Honeywell Enhanced Air Cleaner cabinet to the return air duct (see Fig. 10). g. Install foam tape between the furnace and the Honeywell Enhanced Air Cleaner cabinet. h. Mounting holes are provided for ductwork and furnace attachment. i. Seal seams with tape or caulking after the Honeywell Enhance

Summary of the content on the page No. 16

Before Wiring the Honeywell Enhanced Air Cleaner WARNING: Electrocution Hazard. Be sure the Honeywell Enhanced Air Cleaner is not plugged in before beginning wiring. Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than one disconnect switch. Before wiring the Honeywell Enhanced Air Cleaner: I understand and will comply with applicable local wiring codes and regulations. NOTE:

Summary of the content on the page No. 17

WIRING Wiring the FH8000A (Air Handler) Honeywell Enhanced Air Cleaner STEP ONE: Wiring the FH8000A (Air Handler) a. Ensure power has been shut off from the heating and cooling system. b. Turn the Honeywell Enhanced Air Cleaner power switch off. c. Plug the power cord and the airflow switch cord into their power supply connectors (see Fig. 11). d. Secure the power cord ground wire to the ground terminal on the cabinet using the screw provided in the ground terminal (see Fig 11). POWER CORD INS

Summary of the content on the page No. 18

Wiring the FH8000A (Air Handler) Honeywell Enhanced Air Cleaner AIR PURIFIER FUSED POWER CONNECTOR LEADS POWER CORD FROM INSTALLATION COMPONENTS (IN BAG ATTACHED TO POWER CORD) TO L2 FIELD POWER SUPPLY 5 AMP IN-LINE FUSES TO AIR HANDLER FIELD POWER CONNECTION GROUND: ATTACH TO AIR HANDLER TO L1 FIELD POWER SUPPLY GROUND (CHASSIS) CABLE CONNECTOR TO SECURE POWER CORD TO AIR HANDLER CABINET M28911 Fig. 13. Honeywell Enhanced Air Handler chassis ground. AIR FLOW SENSOR 1) SLIDE FLOW SENSOR TABS 2)

Summary of the content on the page No. 19

O C S WIRING IHI/LOR IDM HSIR 1 PL2 IDR L1 ACRDJ PL1 1 1 2 3 ON PLT OFF W2 Y1 DHUM GCOMWW1Y/Y2R HI HEAT LO HEAT 24V U T A T Wiring the FH8000F (Furnace) Honeywell Enhanced Air Cleaner STEP ONE: Wiring the FH8000F (Furnace) a. Ensure power has been removed from the heating and cooling system. b. Turn the Honeywell Enhanced Air Cleaner power switch off. c. Connect the power cord to the power supply connector (see Fig. 15). d. Secure the power cord ground wire to the ground terminal on the cabine

Summary of the content on the page No. 20

Wiring the FH8000F (Furnace) Honeywell Enhanced Air Cleaner f. Attach the quick connect terminals to the furnace EAC-1 and EAC-2 spade connections, which are polarity neutral. g. Attach the ground ring to furnace chassis ground. NOTE: The FH8000F Honeywell Enhanced Air Cleaner is to be powered by 120 VAC at 60 Hz. NOTE: The Honeywell Enhanced Air Cleaner should only be powered when airflow is present. The furnace control EAC spade connections provide power only when the furnace blower is oper


Alternative user manuals
# User manual Category Download
1 Honeywell 11500 User manual Air Cleaner 260
2 Honeywell 11255 User manual Air Cleaner 27
3 Honeywell 13350 User manual Air Cleaner 25
4 Honeywell 12500 User manual Air Cleaner 50
5 Honeywell 14500 User manual Air Cleaner 54
6 Honeywell 13500 User manual Air Cleaner 4
7 Honeywell 18150 Series User manual Air Cleaner 2
8 Honeywell 18150 User manual Air Cleaner 3
9 Honeywell 16200 User manual Air Cleaner 66
10 Honeywell 17000 User manual Air Cleaner 34
11 Honeywell 203365A User manual Air Cleaner 1
12 Honeywell 17005 User manual Air Cleaner 2
13 Honeywell 18155 User manual Air Cleaner 2
14 Honeywell 50100 User manual Air Cleaner 10
15 Honeywell 50200 User manual Air Cleaner 2
16 Sony PK-HS1FL User manual Air Cleaner 1920
17 Sony PK-R1FL User manual Air Cleaner 11
18 Philips AC4053 User manual Air Cleaner 30
19 Philips AC4002/00 User manual Air Cleaner 13
20 Philips AC4055 User manual Air Cleaner 9