Streszczenie treści zawartej na stronie nr. 1 
                    
                         
FBCR18 & FBKR18 Series 
Gas Rethermalizers 
Installation, Operation, Service, and Parts Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Frymaster, a member of the Commercial Food Equipment Service Association, recommends 
using CFESA Certified Technicians. 
 
819-5686
 
24-Hour Service Hotline 1-800-551-8633 
March 2005
 
                                                                                                                                                                                    
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        NOTICE  IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS  EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED  DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,  AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS  WARRANTY WILL BE VOID.  FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE  LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH  ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN 
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS  TABLE OF CONTENTS      CHAPTER 1:  General Information  1.1 Parts Ordering and Service Information ............................................................................1-1  1.2 Safety Information.............................................................................................................1-1  1.3 Equipment Description......................................................................................................1-2  1.4 Insta
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        CHAPTER 5:  Operator Troubleshooting  5.1 Introduction....................................................................................................................... 5-1  5.2 Operator Troubleshooting Guides ..................................................................................... 5-2  5.3 Replacing the Computer or Computer Wiring Harness .................................................... 5-6    CHAPTER 6:  Service Procedures  6.1 Functional Description......................
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS  CHAPTER 1:  GENERAL INFORMATION    1.1 Applicability and Validity  This manual is applicable to and valid for all FBCR18 and FBKR18 units sold in English- speaking countries.  Where conflicts exist between instructions and information in this manual  and local or national codes of the country in which the equipment is installed, installation and  operation shall comply with those codes.    This appliance is only for professional use and shall be used by
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        1.3 Safety Information  Before attempting to operate your unit, read the instructions in this manual thoroughly.    Throughout this manual, you will find safety notations enclosed in double-bordered boxes similar to  the one below.     DANGER  DANGER boxes contain information about actions or conditions that may cause or  result in injury to personnel, and which may cause damage to your system and/or  cause your system to malfunction.     CAUTION boxes contain information about actions or condit
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        1.6 Definitions  QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL    Qualified/authorized operating personnel are those who have carefully read the information in this  manual and have familiarized themselves with the equipment functions, or who have had previous  experience with the operation of the equipment covered in this manual.    QUALIFIED INSTALLATION PERSONNEL    Qualified installation personnel are individuals, or firms, corporations, or companies which, either in  person or through a r
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS  CHAPTER 2:  INSTALLATION INSTRUCTIONS    2.1 General Installation Requirements  Qualified, licensed, and/or authorized installation or service personnel, as defined in Section  1.6 of this manual, should perform all installation and service on Frymaster equipment.    Conversion of this appliance from one type of gas to another should only be performed by  qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.6 
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        One of the most important considerations of efficient operation is ventilation.  Make sure the equip- ment is installed so that products of combustion are removed efficiently, and that the kitchen ventila- tion system does not produce drafts that interfere with proper burner operation.    The equipment flue opening must not be placed close to the intake of the exhaust fan, and the flue  must never be extended in a “chimney” fashion.  An extended flue will change the combustion char- acteristics 
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        All electrically operated appliances must be grounded in accordance with all applicable national and  local codes.  A wiring diagram is located on the inside of the door.  In the United States and Canada,  the electrical supply must be 120VAC, 60 Hz.  In other countries, refer to the rating plate on the  inside of the door for proper voltages.    FCC COMPLIANCE    The user is cautioned that any changes or modifications to Frymaster computers not expressly ap- proved by the party responsible for 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        2. The rethermalizer must be stabilized by installing restraining chains on units equipped with  casters or anchor straps on units equipped with legs.  Follow the instructions shipped with the  casters/legs to properly install the chains or straps.    3. Level rethermalizers equipped with legs by screwing out the legs approximately 1 inch then  adjusting them so that the rethermalizer is level.    4. For rethermalizers equipped with casters, there are no built-in leveling devices.  The floor whe
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        2.4 Connecting to the Gas Supply     DANGER   Before connecting new pipe to this appliance, the pipe must be blown out thor- oughly to remove all foreign material.  Foreign material in the burner and gas con- trols will cause improper and dangerous operation.     DANGER  When pressure-testing incoming gas supply lines, disconnect the appliance from the  gas line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to  avoid damage to the appliance’s gas tubes and gas valv
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks.  A   soap and water solution should be used for this purpose.    3. Close the drain valve and fill the cookpot with water and boil-out solution to the overflow.  Light  the burners and perform the boil-out procedures that are described in the “Start-Up Procedure”  and “Boiling Out the Cookpot” sections in Chapter 3 of this manual.    4. It is suggested that the burner manifold pressure be checked a
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        FBCR18 & FBKR18 SERIES GAS RETHERMALIZERS  CHAPTER 3:  OPERATING INSTRUCTIONS    3.1 Introduction   WARNING  The on-site supervisor is responsible for ensuring that operators are made aware of  the inherent hazards of operating a gas-fired heated water system, particularly the  aspects of draining and cleaning procedures.    Mechanically, the FBCR18 and FBKR18 rethermalizers are virtually identical. The FBKR18 units  have a manual fill switch in addition to the AutoFill feature.      The primary
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        PROGRAMMING THE FBCR18 SERIES COMPUTER    1. Turn the computer on by pressing the Power  switch.    2. Press the Program Mode  switch.  CodE appears in the left display.  Press, in sequence,  product buttons 1, 6, 5, and 10.  (Press switch again to exit the programming mode.)    NOTE 1: The programming mode is not available while the computer is rethermalizing; the  display will flash BUSY.    NOTE 2: To toggle between Fahrenheit and Celsius temperature display, press the Program  Mode  switch, 
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                          If you rethermalize more food than you use, use the chill feature to quickly reduce the temperature  of the food before refrigerating or freezing.    1. Press the Chill Mode  switch to de-energize the heating elements.    2. Open the drain valve and drain most of the hot water.  The AutoFill will refill the cookpot with  cold water.  If desired, add ice to the cookpot to accelerate the cooling process.    3. Remove the product bags when cooled and return them to the refrigerator or freezer.   
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        Pressing the Boil Mode (L) switch overrides the programmed setpoint and the cookpot temperature  rises to boiling at 212 °F (100 °C).  When the unit is in boil mode, boiL appears in both LED  displays.  The unit remains in boil mode until the Simmer Mode switch is pressed or the unit is  turned off.    Pressing the Simmer Mode (R) switch causes the cookpot temperature to be maintained at the  programmed setpoint.  If the cookpot temperature is above the setpoint, °-HI is displayed in both  LED w
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        NOTE 1: Programming mode is not available while the computer is rethermalizing; the display  will flash BUSY.    NOTE 2: To toggle between Fahrenheit and Celsius temperature display, press the Program  Mode  switch, then enter the code 1 6 5 8 by pressing the corresponding product buttons.  Next, press the Temperature Check/Program Lock  switch to lock in the new display option.    3. Enter the number 1 6 5 0 by pressing the corresponding product buttons.  Unless this code is  entered, programmi
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        Remember:  Stir time 2 must be greater than stir time 1 (or else be “0”).   Stir time 3  must be greater than stir time 2 (or else be “0”).  None of the stir times should be  greater than the rethermalizing time entered in Step 6.  If a stir time exceeds the  rethermalizing time, the stir alarm will not sound.    8. SELP (Select Product) again appears in the left display.  Return to Step 5 and follow all  instructions to program more products.    9. Lock in the programming by pressing the Temper