Streszczenie treści zawartej na stronie nr. 1 
                    
                        ™
EZ Connect
USB/Ethernet Cable Modem
• 	Complies with DOCSIS 1.0 cable modem 	 	
	 requirements
• 	Concurrent USB and Ethernet support
• 	Up to 40Mpbs downstream and 10Mbps upstream
• 	Supports SNMP management 
Quick Install Guide
SMC8002CM-US                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Contents Introduction 1 Key Features 1 Description of Hardware 2 LED Functions 3 Installing the Modem 3 Package Contents 3 Mounting the Modem 4 System Requirements 4 Connecting the Modem 5 Installation 6 USB Installation for Windows 98, Window 2000 and Windows Me 6 Ethernet Installation for Windows 6 Windows 95/98/NT 6 Windows 2000 6 Making a Connection to the Ethernet Port 7 Product Specifications 8 General Specifications 8 Physical Characteristics 8 Troubleshooting 10 Cannot Connect to the Int
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Contents ii                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        Introduction The EZ Connect Cable Modem provides high-speed Internet access over the the same  cable network system that brings cable TV service to the home. The data  transmission rate on the cable connection is asymmetric, in that it provides a higher  data rate in the downstream (receive) direction than in the upstream (transmit)  direction. Asymmetric operation is ideal for typical home and small office use where  files and information are downloaded more frequently than uploaded. This modem
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Quick Installation Guide Description of Hardware The SMC8002CM-US is an external DOCSIS-based cable modem product for high-speed  Internet access applications.The modem provides an optional USB or Ethernet  connection to a PC or LAN. In an Ethernet LAN environment, it supports up to 16 PCs, allowing shared Internet access. The following figure shows the components of this modem:  PWR LINK ACT STS Status LEDs CABLE IN POWER ETHERNET USB RESET Power Socket USB Port Cable Connector RJ-45 Port 2    
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        Installing the Modem LED Functions The EZ Connect Cable Modem contains four LEDs on the top panel. The operational  status of the modem is indicated by the LED conditions listed below. LED Status Description PWR On Red Power is being supplied to the modem. LINK On Green Indicates a valid 10/100Mbps Ethernet link. ACT On Green Indicates that the modem is receiving data from the  service provider. STS Off Indicates that the modem is starting up and searching  for an available channel to use to tra
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Quick Installation Guide Mounting the Modem The SMC8002CM-US comes with a slot-in stand with which it may be mounted vertically or  horizontally. To do this, simply slide the modem on to the stand with the flanges  provided on the base or the side. The two mounting options are illustrated below.  RJ-45 Port USB Port Cable Connector Status LEDs Power Socket Flanges Slot-in stand System Requirements The SMC8002CM-US requires the following PC features to operate:  For USB connection: - A PC equipp
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        Installing the Modem Connecting the Modem Before connecting the EZ Connect Cable Modem, contact your cable service provider  and check the following points:  Be sure that your service provider supplies a two-way data link.  Check that they have set up an Internet Access Account. To do this you will need  to provide information that may include the product number and the modem MAC  address. You will find this information on the label on the base of the modem. The modem must be correctly connect
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        Quick Installation Guide Installation USB Installation for Windows 98,  Window 2000 and Windows Me 1. Insert the square (B-type) USB plug  of the USB cable into the USB port at  the back of the modem and the  rectangular (A-type) USB plug into  USB Port the USB port at the back of the  computer. CABLE IN R ETHERNET USB 2. The “Found New Hardware” screen  RESET USB Cable will appear. Insert the driver disk.  (provided) When prompted for the location of a  driver, enter the drive letter of your  f
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        Installing the Modem Making a Connection to the Ethernet Port  You can use straight-through  Network Adapter Card twisted-pair cable to connect the  Ethernet port on the modem to a PC.  1. Make sure you have installed a  10/100Mbps network adapter card in  the PC. 2. Prepare straight-through shielded  “straight through” or unshielded twisted-pair cables Cat 3, 4, or 5 N ETHERNET USB with RJ-45 plugs at both ends. Use RESET UTP Cable 100-ohm Category 3, 4 or 5 cable  for this 10 Mbps Ethernet  co
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Quick Installation Guide Product Specifications General Specifications Standards Conformance DOCSIS 1.0, IEEE 802.3, IEEE 802.3u, USB 1.1 Cable Modem Requirements Modulation Downstream: 64-QAM/256-QAM (receive) Upstream: QPSK/16-QAM (transmit) Data Rate Downstream: 30.432 Mbps (64-QAM), 42.88 Mbps (256-QAM)  Upstream: 320, 640, 1280, 2560, 5120 kbps (QPSK), 640, 1280, 5560, 5120, 10240 kbps (16-QAM) Frequency Range Downstream: 91 MHz ~ 857 MHz Upstream:5 MHz ~ 42 MHz Bandwidth Downstream: 6 MHz 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        Troubleshooting Troubleshooting  Cannot Connect to the Internet  Confirm that you have established an account with your service provider and that  a two-way cable service is provided.  Check that all cables are connected to the modem and PC. Verify that the proper  cable type is used and its length does not exceed specified limits. Check the cable  connections for possible defects. Replace the defective cable if necessary.   Verify that the modem and computer are powered on.  If the power so
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        Quick Installation Guide Port and Cable Assignments Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only  twisted-pair cables with RJ-45 connectors that conform with FCC  standards. An Ethernet twisted-pair link segment requires two pairs of wires. Each wire pair is  identified by two different colors. Each wire pair must be attached to the RJ-45  connector in a specific orientation detailed below. The Ethernet port on the modem is an MDI-X port, which allows straight-throug
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        Port and Cable Assignments Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal  crossover (MDI-X), the two pairs of wires must be straight-through. Straight-Through RJ-45 Pin Assignments End 1 End 2 1 (RD+) 1 (TD+) 2 (RD-) 2 (TD-) 3 (TD+) 3 (RD+) 6 (TD-) 6 (RD-) Crossover Wiring If the twisted-pair cable is to join two ports and either both ports are labeled with an  “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        Quick Installation Guide EMI Certification FCC Class B Certification (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the  following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that  may cause undesired operation. Warning: This equipment has been tested and found to comply with the limits for a  Class B digital device, pursuant to Part 15 of the FCC Rules. These li
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        EMI Certification CE Mark Declaration of Conformance This information technology equipment complies with the requirements of the  Council Directive 89/336/EEC on the Approximation of the laws of the Member  States relating to Electromagnetic Compatibility and 73/23/EEC for electrical  equipment used within certain voltage limits and the Amendment Directive 93/68/ EEC. For the evaluation of the compliance with these Directives, the following  standards were applied: RFI  Limit class B according 
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        Quick Installation Guide Safety Compliance Underwriters Laboratories Inc. (USA) Important! Before making connections, make sure you have the correct Cord Set.  Check it (read the label on the cable) against the following specification list. Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated  15 A, 125 V 240 Volts (Europe only) Cord S
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        Warranty Warranty SMC warrants to the original owner that the product delivered in this package will  be free from defects in material and workmanship for a period of three (3) years from  the date of purchase from SMC or its Authorized reseller. For the warranty to  apply, you must register your purchase by returning the registration card indicating  the date of purchase and including proof of purchase. There will be a minimal  charge to replace consumable components, such as fuses, power trans
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                          FOR TECHNICAL SUPPORT, CALL:   From U.S.A. and Canada (24 hours a day, 7 days a week)    (800) SMC-4-YOU; (949) 679-8000; Fax: (949) 679-1481    From Europe (8:00 AM - 5:30 PM UK Time)    44 (0) 118 974 8700; Fax: 44 (0) 118 974 8701     INTERNET    E-mail addresses:     techsupport@smc.com    european.techsupport@smc-europe.com   Driver updates:      http://www.smc.com/index.cfm?action=tech support drivers downloads   World Wide Web:      http://www.smc.com/    http://www.smc-europe.com/    F