Streszczenie treści zawartej na stronie nr. 1 
                    
                        1500 Watt DC to AC Power Inverter
C o n v e r t s 1 2 V D C B a t t e r y P o w e r 
t o 1 1 0 V A C H o m e P o w e r
O W N E R ' S M A N U A L
– SAVE THESE INSTRUCTIONS –
The recommended source of power is a 12-volt deep-cycle battery 
due to their high reserve power capacity. Automotive batteries 
are recommended for only a short period of time of an hour or less. 
Model PI-1500 00-99-000628/0206                                                                                                  
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        The advanced surge capacity of the PI-1500 power  inverter gives it the means to start most electrical devices  including: color televisions, TV/VCR/d Vd combinations,  small microwaves, refrigeration electric coolers, small air  conditioners. Warning: Handling the cord on this product or cords  associated with accessories sold with this product, may  expose you to lead, a chemical known to the State of  California to cause cancer and birth defects or other  reproductive harm. Wash hands after h
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        • d o not place the inverter in direct sunlight. The ideal air  temperature for operation is between 30º and 105ºF. • Keep the inverter well ventilated in order to properly dis- perse heat generated while it is in use. • While in use, make sure there are several inches of clear- ance around the top and sides of the inverter.  • Do not use the inverter near flammable materials. • d o not place or install the inverter in areas such as bat- tery or engine compartments where fumes or gases may  accu
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        • If you are powering the inverter with an automobile or ma- rine battery, start the engine every 30 to 45 minutes and  let it run for about 10 minutes to recharge the battery. • If you hear a continuous alarm or automatic shut down, turn  the inverter o FF immediately. d o not restart the inverter  until the source of the problem has been identified and  corrected. • d isconnect the inverter when not in use in order to avoid  battery drain. Before Using PI-1500 It is important to know the conti
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        In the event of a power overload, the inverter is designed  to automatically shut down. This safety feature prevents  damaging the inverter while testing devices and equip- ment within the 1500-watt range. If a device will not operate properly when first connected  to the inverter, turn the inverter rocker switch o N (I), o FF  (o ), and o N (I) again in quick succession. If this proce- dure is not successful, it is likely that the PI-1500 inverter  does not have the required capacity to operate
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        2. Place the back of the PI-1500 with the mounting bracket  against a secure and flat surface. 3. Attach the inverter to the flat surface using corrosion  resistant screws. Inverter Features: A. o N/o FF Rocker Switch – Turns inverter on and off. B. led Indicator l ight – (Green = power o N, Red =  o verload, interruption in power). C. Two, 110V GFCI AC o utlets d . o ne Pair, 12-Volt Power Cords e. Two, High Speed Cooling Fans – keeps inverter cool.  The speed of the fan is faster as the load i
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Grounding the PI-1500 To avoid electrical shock, it is necessary to ground the  PI-1500 Inverter as well as the device powering it. The  inverter should be grounded using #8 AWG copper wire  (not included). Note: d o not turn on the inverter or the power source  until the inverter and the power source are grounded. 1. Turn off the PI-1500. 2. l ocate the chassis ground screw underneath the  negative terminal on the left side of the inverter. Unscrew  the two hex nuts and one washer. 3. Strip the
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        Connecting Inverter Cables The inverter and the power source must be in the o FF  mode. Inverter Connection: 1. l ocate the positive and negative plastic terminals  located on the left side of the inverter. Using a flathead  or standard screwdriver, unscrew the positive (red) and  negative (black) terminal screws just enough to be able  to insert the bare end of the connector cables.  2. Insert the bare end of the positive (red) cable into the  positive terminal and bare end of the negative (bla
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        Connecting Your PI-1500 t o t urn o N: 1. Push the rocker switch, located on the right side, to the  “o N” (I) position. The led indicator light should glow  GRee N verifying the inverter is receiving power and can  deliver power to your device. (A brief audio alarm may  sound or red LED may flash. This is normal.)  2.  Turn on the power source or device to be powered. Note: If more than two devices are to be powered, start  one device at a time to avoid a power surge and overload- ing the inver
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        Using GFCI o utlet The GFCI (Ground Fault Interrupter) must be tested before  each use.  To test: 1. Turn the inverter o N. 2. Push the "ReSeT" button located on the GFCI receptacle,  first to assure normal GFCI operation.  3. Plug a nightlight (with an "o N/o FF" switch) or other  product (such as a lamp) into the GFCI receptacle and  turn the product "o N."  4. Push the "TeST" button located on the GFCI receptacle.  The nightlight or other product should go "o FF."  5. Push the "ReSeT" button,
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        inverter to reset. To reset: press the “TeST” button (stops  flow of electricity to outlet) on the outlet face. Next, press  the “RESET” button (restores flow of electricity to outlet)  on the outlet face. LeDs and Audio Alarms Green – Power o n Red l ight and/or Audio Alarm Current o verload – Red led glows for a short time and  inverter shuts down. Current load too high for inverter.  Reduce current demand. Voltage o verload – Red led glows and inverter shuts  down. Voltage range of 15.5V ± 0.
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        power consumption. When the inverter is o FF, no lights  appear. Using the Inverter to o perate a t V or Audio Device The inverter is shielded and filtered to minimize signal  interference. d espite this, some interference may occur  with your television picture, especially with weak signals.  Below are some suggestions to try and improve reception. Make sure the television antenna produces a clear signal  under normal operating conditions (i.e., at home plugged  into a standard 115V AC wall out
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        Blown Fuse A blown fuse is usually caused by reverse polarity or a  short circuit within the device or equipment being operated.  If the fuse blows, take the inverter to a qualified techni- cian for repair. Power Source Your average automobile or marine battery will provide an  ample power supply to the inverter for 30 to 45 minutes  even when the engine is off. The actual length of time the  inverter will function depends on: 1.  Age and condition of the battery. 2.  Power demand being placed b
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        Safety Features The led Indicator light will turn from GR eeN to R ed and  the inverter will automatically turn itself off when: 1.  The power input from the battery drops to approximately  10 volts. (When the power input drops to approximately  10.5 volts, an alarm will sound for an extended period). 2. The power input from the battery exceeds 15.5 volts. 3.  The continuous load demand from the equipment or  device being operated exceeds 1500 watts. 4. The case temperature exceeds 140 ºF. Atten
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        St AGe 2: The inverter then converts the 145-volts d C  into 110-volts AC (household voltage) using advanced  MOSFET transistors in a full bridge configuration. A "modi- fied sine wave" waveform is generated by this conversion.  t roubleshooting PRo BLeM: Low or No o utput Voltage Reason/Solution 1. Poor contact at terminals.  Unhook and rehook the 12-volt connections.  2.  Using incorrect type of voltmeter to test output  voltage.   Use a true RMS reading meter.  PRo BLeM: Red LeD o n Reason/So
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        PRo BLeM: Audible Alarm o n All t he t ime Reason/Solution 1.  Input voltage below 11 volts.   Recharge or replace battery to maintain adequate power  input. 2.  Poor or weak battery condition.   Recharge or replace battery. PRo BLeM: Device Does Not Work Reason/Solution 1. Device does not turn on.   Try turning the inverter o N, then o FF, then o N again.  Contact the device manufacture for start up surge and/or  if the device is compatible with a modified sine wave.  An inverter producing a la
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        SPeCIFICAt Io NS: Maximum Continuous Power ............................ 1500 watts Surge Capability (Peak Power) ........................ 3000 Watts No l oad Current d raw ............................................. < 0.6A Wave form ...........................................Modified Sine Wave Input Voltage Range ....................................10.5V–15V d C AC outlets ..................................................Two, 110V GFCI   LIMIte D WARRANt Y Schumacher electric Corporation warr
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        Schumacher electric Corporation,  Warranty Service d epartment 1025 Thompson, Hoopeston, Il  60942 Phone: 800-621-5485  (Hours:  a.m. - 4:30 p.m. CST) You will be responsible for all insurance and freight or  other transportation charges to the factory or point of  repair. We will return your inverter freight prepaid if repair  is covered under warranty. Your inverter should be prop- erly packed to avoid damage in transit since we will not  be responsible for any such damage. In no event shall