Streszczenie treści zawartej na stronie nr. 1 
                    
                        Model ST-2400S 
Horsepower Computer System 
User Manual 
 
 
 
In the USA: 
Star Test Dynamometer, Inc. 
712 Thistlewood Court 
Normal, IL 61761 
Phone: (309) 826-1484 
 
 
 
In Mexico, Central & South America: 
Negociaciones Fuentes S.A. DE CV 
Av. La Luz 4549 Col. Cortijo del Rio 
Monterey, N.L. Mexico 64890 
Phone: 81.8349.1416 
 
 
 
Manufacturered by: 
Ries Labs, Inc. 
2275 Raven Road 
Farina, IL 62838 
Phone: (618) 238-1400 
eMail: admin@rieslabs.com                                        
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                          Table of Contents    Description ---------------------------------------------------------------- 3    Installation ---------------------------------------------------------------- 3    Power Supply --------------------------------------------------------- 4     Operation of the unit from 220-260 VAC 50-60 Hz ----------- 4    Operation ------------------------------------------------------------------ 4    Computer Function Switch ---------------------------------------- 5    System Power LED 
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Description:    The function of the Model 2400S Horsepower Computer is to provide the operator with a  continuous digital readout of the RPM, TORQUE, POWER (Horsepower or Kilowatts)  and percentage of Torque Rise ( % TORQUE RISE) when properly attached to a  compatible dynamometer.    The RPM readout shows the operator the rotation speed (rotations per minute) of the  power shaft of the dynamometer.  The RPM is measured by a pickup and gear  combination that is mounted on the dynamometer and cou
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                          Power Supply:    The Model 2400S horsepower computer is normally operated from 110 to 125  VAC (60 Hz) using the outlet mounted power supply that is supplied with the  unit.  The power consumption of the computer is very low and the unit has a very  high tolerance for power supply variations, so nearly any standard 115 VAC  utility power outlet should power the unit adequately.  See (below) information on  a special (optional) “wide-range” power supply which will power the unit  properly when 
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        values are computed and displayed.  This process is repeated continuously while  the unit is in operation.    Computer Function Switch:    The computer function switch is used to turn the system power ON/OFF  and to control the functional operation of the horsepower computer.  The  function switch has four positions ( “OFF”, “ZERO”, “CHECK”, and  “RUN”).    In the “OFF” position, the power to the horsepower computer (and the  load cell, etc.) is turned “OFF”.  The power is turned “ON” in the oth
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        10,000 3750 2856  CHECK readings using Ft.-Lbs. & Horsepower   6                                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                          Load Cell Rating (Ft.-Lbs.) Torque (N-M) Power (KW)  100 (135.5 N-M) 50.84 21.30  200 (271 N-M) 101.6 42.60  500 (677.5 N-M) 254.2 106.5  1,000 (1355 N-M) 508.4 213.0  2,000 (2710 N-M) 1016 426.0  5,000 (6775 N-M) 2542 1065  10,000 (13550 N-M) 5084 2130  CHECK readings using Newton-Meters and Kilowatts    The ZERO and CHECK  positions of the computer function switch  provide quick checks to determine whether the horsepower computer is  operating properly.  Proper readings indicate that the maj
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        The torque set switch is used to set the torque reference which is used to  compute the % Torque Rise reading.  To set the torque reference, proceed  as follows:    Run the engine at it rated speed, loaded at rated power or torque output.  This represents the 100% torque output condition for the engine.    With the engine running at its rated speed and load, press the Torque Set  switch momentarily.  The reference torque value is now set to the rated  engine 100% torque and the % Torque Rise dis
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                          When the horsepower computer is used with a companion personal  computer, a standard (9 pin) RS-232-C extension cable is used to connect  the two computers together.  This extension cable is normally 10 feet long,  but can be up to 50 feet long (and even longer if special “long range” RS- 232-C extension cables are used).  The print rate and manual print  switches serve to notify the personal computer which measurements are to  be saved (or printed) in much the same way they are used when a pr
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        recording can be controlled from the 2400S horsepower computer  and / or using the personal computer’s keyboard or mouse.    Recorded data can be printed on the PC’s printer and / or can be  easily “imported” into Microsoft Excel (or other analysis  programs) for further operations such as graphing, etc.    Dyno32 is compatible with most Windows based computer  systems including Win95, Win98, WinMe, Win2000 and WinXP.    Data Recording and Graphing Software for the 2400S:    DynoGraph software c
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        2.) The instrument has been moved (re-installed) from one dynamometer  to another.  3.) The load cell of the dynamometer has been replaced, overloaded,  dropped or otherwise mistreated.  4.) The power supply to the unit has been repaired or replaced.  5.) Prior to any measurements that require especially high accuracy.  6.) The instrument has been repaired, exchanged or replaced.    IMPORTANT NOTE:    The Model 2400S is a delicate instrument and should be treated accordingly.  It  should not be 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        the torque arm of the dynamometer to insure that there is no force  being applied to the load cell (which would result in an inaccurate zero  calibration).  Remove the calibration access cover panel and set the  calibration mode switch to the ZERO position.  Also, be sure that  the shunt resistor switch is set to the OFF position. At this time note  that the RPM display of the unit should indicate “1111” and the  POWER display should indicate “0000”.  The TORQUE display  indicates the TORQUE and
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        positive and negative torque to the unit) and verify that the torque reading returns  closely to the same value. A failure here indicates a likely problem with the  dynamometer.  Have the dynamometer checked by your dealer or dyno service  person.  1.3 Make sure that the load has been completely removed from the load cell.   Disconnect the load cell from the torque arm of the dynamometer by removing  the coupling fastener.  If this does not correct the excessive zero offset a likely  defective o
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        dynamometer.  The calibration torque produced is equal to the sum of the torque  produced by the Torque Test Bar itself plus the torque produced by the test  weight(s) – which is equal to the total weight of the test weight(s) times the  horizontal distance from the center line of the dyno to the position of the test  weights.  For example, assume the torque of the torque test bar itself is 17 Ft.- Lbs., the total weight is 100 Lbs. and the horizontal distance is 4.00 Ft.  The  calibration torqu
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                          In Case of Difficulty:    The following is a troubleshooting guide that will help you to resolve any problems that  may arise.    The Model 2400S Horsepower Computer contains no user serviceable parts.  If it needs  to be repaired you may return the unit to your dealer (who can also assist you with other  repair problems such as problem diagnosis, replacement of the load cell, RPM pickup,  other dynamometer repairs, etc.) or directly to:    In the USA:  STAR TEST DYNAMOMETER, INC.  712 THISTLE
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                         The following table is useful for you to determine that cause of any problems that you  might be able to fix yourself.    Problem Possible causes and remedies  No indication on displays. There is likely no power to the unit. Check the power supply  Power LED is not lit. to be sure it is plugged in. Check the fuse on the front panel  of the unit. Replace ONLY with the correct ½ amp fuse. DO  NOT use a slow blow or higher value fuse as this can result  in severe damage to the unit.  Power LED com
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        and the RPM sensor gear.  Make sure that they are not loose  and that the runout of the RPM gear is not excessive. Check  the RPM sensor connector to be sure that it is tight. Check  the cable from the RPM pickup to the horsepower computer.   Check the power supply to the horsepower computer. Have  the horsepower computer checked.  Torque readings are Operate the unit using the ZERO and CHECK functions.  If  inaccurate the readings do not agree with the tables above, unit needs  to be repaired.