                          ICC  ASD-G9ETH Multiprotocol Ethernet Interface  User's Manual    Part Number 10639-2.300-000  Printed in U.S.A.  ©2007-2011 Industrial Control Communications, Inc.  All rights reserved        NOTICE TO USERS  Industrial Control Communications, Inc. reserves the right to make changes and  improvements to its products without providing notice.    Industrial Control Communications, Inc. shall not be liable for technical or editorial  omissions or mistakes in this manual, nor shall it be liable f
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                          ICC  Usage Precautions    Operating Environment  • Please use the interface only when the ambient temperature of the  environment into which the unit is installed is within the following  specified temperature limits:  Operation: -10 ∼ +50 °C (+14 ∼ +122 °F)  Storage: -40 ∼ +85 °C (-40 ∼ +185 °F)  • Avoid installation locations that may be subjected to large shocks or  vibrations.  • Avoid installation locations that may be subjected to rapid changes in  temperature or humidity.  Installation 
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                          ICC  TABLE OF CONTENTS  1.  Introduction ................................................................................... 6  2.  Features ......................................................................................... 7  3.  Precautions and Specifications .................................................. 9  3.1  Installation Precautions ......................................................................... 9  3.2  Maintenance Precautions .......................................
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                          ICC  10.4.5  Parameter List Filter ................................................................... 28  10.4.6  Radix Selection........................................................................... 29  10.5  PROFINET Tab ................................................................................... 30  10.5.1  Information Window .................................................................... 30  10.5.2  Device Identification and Configuration .................................
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                          ICC  11.2  Using FTP with Windows Explorer ...................................................... 59  11.3  Using FTP with a Windows Command Prompt .................................... 60  11.4  Using FTP with Core FTP LE .............................................................. 62  12.  Loading New Application Firmware ..................................... 64  13.  Protocol-Specific Information ............................................... 66  13.1  Modbus/TCP .........................
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                          ICC  1. Introduction  Congratulations on your purchase of the ICC Multiprotocol Ethernet Interface for the  Toshiba G9, H9, Q9 and VFAS1 families of Adjustable Speed Drives (ASDs).  This  interface allows information to be transferred seamlessly between the drive and  several different Ethernet-based fieldbus networks with minimal configuration  requirements.  The interface installs directly into the drive enclosure and presents a  standard 10/100BaseT Ethernet port for connection to the Ether
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                          ICC  2. Features  Ethernet Port  IEEE 802.3 10/100BaseT Ethernet compliant.  Shielded RJ45 connector accepts  standard CAT5-type 8-conductor unshielded twisted-pair (UTP) patch cables.   Supports multiple simultaneous protocols.    Supported Protocols  The interface currently provides server support for the following fieldbus protocols:  • Modbus TCP  • EtherNet/IP  • Allen Bradley CSP (also known as “PCCC” and “AB Ethernet”)  • BACnet/IP  • PROFINET IO    Note that use of PROFINET IO is mutua
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                          ICC  Network Timeout Action  A configurable network timeout action can be programmed that allows registers to  have their own unique "fail-safe" conditions in the event of a network interruption.   Refer to section 10.7.5.    Field-Upgradeable  As new firmware becomes available, the interface can be upgraded in the field by the  end-user.  Refer to section 12 for more information.    EtherNet/IP Data Access Options  The EtherNet/IP protocol provides access to inverter data via explicit messagi
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                          ICC  3. Precautions and Specifications  Rotating shafts and electrical equipment can be hazardous. Installation,  operation, and maintenance of the ASD and interface board shall be  performed by Qualified Personnel only.  Qualified Personnel shall be:  • Familiar with the construction and function of the ASD and interface  board, the equipment being driven, and the hazards involved.  • Trained and authorized to safely clear faults, ground and tag  circuits, energize and de-energize circuits in
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                          ICC  • Follow all warnings and precautions and do not exceed equipment  ratings.  • The ASD maintains a residual charge for a while after turning supply  power off.  After turning supply power off, wait at least ten minutes  before servicing the ASD or interface board. Ensure that the  Charge LED is off prior to beginning installation.  • For further ASD-specific precaution, safety and installation  information, please refer to the applicable Adjustable Speed Drive  Operation Manual supplied w
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                          ICC  3.3 Inspection  Upon receipt, perform the following checks:  • Inspect the unit for shipping damage.  • Check for loose, broken, damaged or missing parts.  Report any discrepancies to your ICC or Toshiba sales representative.      3.4 Storage  • Store the device in a well ventilated location (in its shipping carton, if possible).  • Avoid storage locations with extreme temperatures, high humidity, dust, or metal  particles.      3.5 Warranty  This communication interface is covered under 
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                          ICC  3.7 Environmental Specifications    Item Specification  Indoors, less than 1000m above sea level, do not  Operating Environment expose to direct sunlight or corrosive / explosive  gasses  Operating Temperature -10 ∼ +50 °C (+14 ∼ +122 °F)  Storage Temperature  -40 ∼ +85 °C (-40 ∼ +185 °F)  Relative Humidity 20% ∼ 90% (without condensation)  2 Vibration 5.9m/s {0.6G} or less (10 ∼ 55Hz)  Non-isolated, referenced to ASD control power  Grounding  ground  Cooling Method Self-cooled  Communica
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                          ICC  4. Interface Board Overview      Mounting Tabs  Drive Connector  MAC ID  Ground Plate  Configuration Switches LEDs  Shielded RJ45 Ethernet Jack    Note: The configuration switches are used for factory test only, and should remain in  the OFF (up) position at all times.  13                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                          ICC  5. Installation  This interface card has been designed for quick and simple installation.  The card is  connected to the drive's control board via a 30-pin rectangular connector, and is  mechanically supported via an integral housing that seamlessly mates with the  drive’s enclosure.  The only tool required for installation is a flat-blade screwdriver.    Before opening the drive, please observe all safety precautions as outlined on the  drive's front cover and in the operation manual.   
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                          ICC    Figure 2: Removing the Drive's Front Cover    4. Install the interface card into the drive by inserting the tabs on the lower legs of  the interface housing into the corresponding slots on the drive’s enclosure.   Rotate the interface housing up and press it onto the drive enclosure’s mounting  tabs, depressing firmly until the housing snaps into place (Figure 3).  Double- check that the plastic bosses located on the left and right side of the drive  enclosure are properly inserted into
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                          ICC  depressing firmly until the front cover snaps into place (Figure 4).  Double-check  that the plastic bosses located on the left and right side of the interface housing  are properly inserted into the corresponding recesses on the back of the front  cover, and that the front cover is overall secure and flush with the interface  housing.    Figure 4: Reinstalling the Drive's Front Cover    6. Insert the network cable into the Ethernet jack.  Ensure that the connector is fully  seated into t
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                          ICC  6. LED Indicators  6.1 Front Panel  The interface board has 5 bicolor (red/green) LEDs that are visible through the  ASD’s front cover (labeled 2.1 through 2.5).                                Interface Status 2.1      EIP Module Status /  2.2    Reserved    EIP Network Status /  2.3   PROFINET Cnxn Status      Ethernet Activity 2.4      Heartbeat 2.5      Interface Status:  Normally solid  green during operation.  If a fatal error  occurs, this LED will flash a red error  code. The numbe
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                          ICC  EIP Network Status / PROFINET IO Connection Status:  When the multi-protocol  firmware image (with EtherNet/IP support) is loaded, this LED conforms to the  prescribed “network status LED” behavior as dictated in the EtherNet/IP  specification, Volume 2, Chapter 9.  When the PROFINET IO firmware image is  loaded, this LED is on solid green when the controller has established a link with the  interface board and is communicating with it.    Ethernet Activity:  Blinks green briefly when net
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                          ICC  7. Configuring the IP Address  Before you can access the interface from your web browser or begin using it as a  part of your automation network, you must know its IP address.  The interface comes  from the factory configured to obtain an IP address dynamically (DHCP/BOOTP).  You can determine the interface’s current IP address using the discovery software  included on the CD provided with the interface, or available from the ICC homepage  at http://www.iccdesigns.com.      7.1 Via the Fi