Streszczenie treści zawartej na stronie nr. 1 
                    
                        Owner’s Manual 
 1803PC, 1815, 1817  
 PC Programmable Telephone Entry Systems 
DoorKing, Inc. 
120 Glasgow Avenue 
Inglewood, California  90301 
U.S.A. 
Phone: 310-645-0023 
Fax: 310-641-1586 
www.doorking.com 
P/N 1815-065 REV J, 3/01 
Copyright 2001 DoorKing, Inc.  All rights reserved. 
                                                                                                                                                                                                                 
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Use this manual with the following models only.    All 1803PC models with circuit board 1844-010 REV A and B.  All 1815 models with circuit board 1840-010 REV D and E.  All 1817 models with circuit board 1841-010 REV F and G.    DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes.  Additionally, DoorKing, Inc. makes no representations or warranties
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        TABLE OF CONTENTS    Preface  Important Notices......................................................................................................................................................6  General Information ..................................................................................................................................................7  Features ..........................................................................................................................
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        3.4 Programming Letters, Numbers and Messages  3.4.1 Programming Letters and Numbers .........................................................................................37  3.4.2 Programming the User Message – 1815..................................................................................38  3.4.3 Programming the Instruction Message – 1815 ........................................................................39  3.4.4 Programming the User Message – 1817.............................
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        IMPORTANT NOTICE    FCC - UNITED STATES  This equipment has been tested and found to comply with the limits for a class A digital device,  pursuant to Part 15 of the FCC Rules and Regulations. These limits are designed to provide  reasonable protection against harmful interference when the equipment is operated in a commercial  environment. This equipment generates, uses, and can radiate radio frequency energy and, if not  installed and used in accordance with the instruction manual, may cause h
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        GENERAL INFORMATION    • Prior to beginning the installation of the telephone entry system, we suggest that you become  familiar with the instructions, illustrations, and wiring guidelines in this manual.  This will help  insure that you installation is performed in an efficient and professional manner.  • The proper installation of the telephone entry panel is an extremely important and integral  part of the overall access control system.  Check all local building ordinances and building  codes
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        FEATURES    • Can provide service for up to 3000 residents and can store up to 8000 card, transmitter or  digital PIN codes when ordered with 3000 MemPLUS chip set.  • System can be programmed via modem or RS-232 interface with the Remote Account  Manager for Windows software included with the unit.  Programming via RS-232 requires an  additional cable that is not included with the unit (P/N 1818-040).  • System keypad will emit DTMF tones after a call is answered allowing the system to be used 
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        SECTION 1 - INSTALLATION    Order your telephone line at least two weeks prior to the planned installation date.  This will assure  that a phone line is available when the unit is installed.  The telephone company will require the  following information from you:    Type: Touch Tone, Loop Start  Ringer Equivalence: 0.0 A  Jack Type: RJ11C  FCC Registration (US): DUF6VT-12874-OT-T  DOC (Canada): 1736 4528 A  Electrical Listing: Complies with U.L. 294 - ETL Listed    CALLER ID:  You may want to co
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        1.1.1 Surface Mount Units  Surface mount units can be mounted directly to a wall or pilaster, or can be post mounted using a  DoorKing heavy-duty mounting post (p/n 1200-047 and 1200-048).  Be sure the unit is mounted  securely and is not subject to vibration from closing doors or gates.    CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or  in suc
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        1.1.2 Surface Mount Units with Recess Box  Surface mount units can be semi-flush mounted into a wall or pilaster by using the optional recess- mounting box (p/n 1803-150).  Be sure the unit is mounted securely and is not subject to vibration  from closing doors or gates.    CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be mounted a minimum of ten (10) feet away from the gate and gate operator, or  in such a way that a pe
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        1.1.3 Flush Mount Units  Flush mount units are installed into a wall with flush mount kits 1814-065 (stainless) or 1814-066  (gold).  Flush mount kits are not included with the entry system.  Flush mount units are not designed  for direct exposure to the weather.  Be sure the unit is mounted securely and is not subject to  vibration from closing doors or gates.    CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be mounted 
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        1.1.4 Flush Mount Rough-in Box  The flush mount installation kit has two parts; the rough-in box and the trim ring.  The rough-in box is  installed first.  12.75 1.875 9.0 3.875 10-24 x 1.125 Stud 1.125 DIA 3.5 1.75 9.25 .25 DIA 1.75 6.375 11.0 13    1.75 11.0 1.75 1.25 4.25 7.25 10.25 13.25 14.5                                                                                                                                                                                                           
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        1.1.5 Flush Mount Trim Ring  Flush mount units can be mounted by using the 1814-065 (stainless) or 1814-066 (gold) mounting kit.   Flush mounting kits are not included with the unit.  Flush mount units are not designed for direct  exposure to the weather.  Be sure the unit is mounted securely and is not subject to vibration from  closing doors or gates.    CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be mounted a minimu
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        1.1.6 Flush Mount Surface Mounting Kit  Flush mount units can be surface mounted by using the optional 1814-152 surface mount trim ring.   Flush mount units are not designed for direct exposure to the weather.  Be sure that the unit is  securely mounted and is not subject to vibration from closing doors or gates.  CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be mounted a minimum of ten (10) feet away from the gate and g
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        1.1.7 Wall Mount Units  Wall mount units (models 1815 and 1817 only) are designed to be mounted directly onto a wall  without the need of cutting a large hole as is necessary with flush mount units.  Wall mount units are  not designed for direct exposure to the weather.  Be sure the unit is mounted securely and is not  subject to vibration from closing doors or gates.    CAUTON!  If this entry system is used to control a vehicular gate with an automatic gate operator, the  entry system must be m
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        1.2 MEMORY CHIP INSTALLATION    The telephone entry system is shipped with two memory chips packaged in a separate box inside the  shipping container.  The memory chips must be installed for the telephone entry system to operate.    CAUTION!!  Do not install the memory chips with power to the telephone entry system turned  on.  Attempting to install the memory chips with power on will irrevocably damage the chips.    CAUTION!!  The memory chips are a static sensitive component.  Discharge any st
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        1.3 POSTAL LOCK INSTALLATION    At some locations, such as gated communities, it will be necessary to provide access to the mail  carrier so that they can deliver the mail.  Mail carrier access will be provided by the installation of an  Arrow Postal Lock.  This is the same lock that the Post Office uses for gang mailboxes.  These locks  are not available to the public.  The installer or the building owner/manager will have to call the Post  Office and arrange for the installation of this lock i
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        SECTION 2 – WIRING    Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the  instructions, illustrations, and wiring guidelines in this manual.  This will help insure that you  installation is performed in an efficient and professional manner.    The wiring of the telephone entry panel is an extremely important and integral part of the  overall access control system.  Use proper wire for the communication line, power wires, and  be sure that the s
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        RS-232 Input (OPTIONAL) Connections to 2348 Elevator Control Board (OPTIONAL) Weigand Power Inputs for weigand control devices (OPTIONAL) 12 34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 16 VAC 16 VAC 20 VA 20 VA        Power Wiring Maximum Distance Phone Wiring Maximum Distance  100 Feet 18AWG 800 Feet 24 AWG  200 Feet 16 AWG 1600 Feet 22 AWG     Weigand Wiring Maximum Distance Elevator Control Maximum Wiring  500 Feet Belden 9931 500 Feet Belden 9931  500 Feet Consolidated 500 Feet Consolidate