Streszczenie treści zawartej na stronie nr. 1 
                    
                          Dynamix HP-51M User Manual EN-V1.00 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Dynamix HP-51M 
Dynamix HP-51M 
 
HomePNA3.1 Coax MDU Master Bridge 
 
 
 
 
 
 
User’s Guide 
User’s Guide 
 
Version 1.0 
Jul. 2008 
 
 
 
 
                                                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        S TATEMENT  TATEMENT  S This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and    (2) This device must accept any interference received, including interference that  may cause undesired operation.    NOTE: This equipment has been tested and found to comply with the limits for a  Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed  to provide reasonable 
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                          Dynamix HP-51M User Manual EN-V1.00        TA AB BL LE E  O OF F  C O ON NT TE EN NT TS S  T C  INTRODUCTION __________________________________________________________ 1
 INTRODUCTION Features _________________________________________________________________________ 1
 Glossary _________________________________________________________________________ 1
 INSTALLATION ___________________________________________________________ 2
 INSTALLATION Packing List ________________________________________
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        Allowed Source _______________________________________________________________________ 20
 Telnet/Http/Snmp Setup _______________________________________________________________ 21
 System Log _____________________________________________________________________________ 22
 System Time ____________________________________________________________________________ 22
 Static MAC _____________________________________________________________________________ 23
 Reboot System__________________________
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                          Dynamix HP-51M User Manual EN-V1.00      swqosrate____________________________________________________________________________ 38
 swqostc _____________________________________________________________________________ 38
 swsmac _____________________________________________________________________________ 38
 swtagvlan ____________________________________________________________________________ 39
 tftp __________________________________________________________________________________ 39
 time 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  1  INTRODUCTION  INTRODUCTION  This chapter describes the features of your HomePNA3.1 over Coax to Ethernet Master (Management) Bridge --  HP-51M. Refer to “HomePNA3.1 over Coax” as HCNA from this point.    Features  ♦ One HCNA Port for Driving HomePNA3.1 Signal into Existing Coaxial Cable   ♦ One TV/Antenna Port for TV Set Connection or for TV Signal from VHF/UHF Antenna/CATV  ♦ Two Fast Ethernet Port with Auto-Detect MDIX Function(Auto Crosso
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  2  INSTALLATION  INSTALLATION  This chapter describes the installation procedure for your bridge.    Packing List  Your package should come with the equipment listed below,    ♦ One Main Unit (HCNA to Ethernet Master Bridge) HP-51M  ♦ One DC 5V Power Adaptor  ♦ One F-Type Coaxial Cable (RG-59U)  ♦ One RJ-45 Ethernet Cable (CAT-5)    Rear Panel      Figure 1: Rear Panel of HP-51M    Connectors  1. DC5V: Connect to the power adapter plug.  2. LAN
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  Connecting the Cables  To establish a new coax networking system by HP-51M, reroute the CATV/Antenna signal source over coax toward  HP-51M ‘TV/Antenna’ port and connect HP-51M ‘HCNA’ port to the original coax entrance to building. HP-51M  works as a Combiner for TV and HCNA signal. In each Dwelling Unit, use the HCNA EP to extract the TV signal  and Ethernet packets. See Figure 2 for the detail cabling in one MDU,       HP-51S  Satellite/CAT V
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide    You can also use other Combiner or Mixer-Splitter with HP-51M to build the same system, see the following Figure  3 for different cabling,  Satellite/CATV VHF/UHF  Mixer  Combiner  EP  HP-51M  Splitter  M/C  Optical Fiber  ISP    Figure 3: Different Cabling of HP-51M    NOTE: After power up HP-51M, the led ‘SynMode’ will always be glowing, and led ‘Link/Act’ will light up for at  least one EP is detected on the HCNA network. A dimmed led ‘Lin
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  3  CONFIGURATION  CONFIGURATION  This chapter describes the configuration procedure for your bridge.     Configuration Methods  To access and configure your bridge, choose one of the following methods:    ♦ Use Web Browser  ♦ Use Telnet Program   ♦ Use SNMP Manager or MIB Browser    Use Web Browser  Web browser is the easiest tool to configure the bridge. The factory default IP address of HP-51M is ‘192.168.1.1’  and the default subnet mask is 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  System Setup (TCP/IP Properties)    The main window contains the left sub-window for the items to be configured, and the right sub-window displays  the contents for the selected item. Click your mouse on the item in the left window will pop out the corresponding  item-window in the right side. Click on the ‘Apply’ button (or ‘OK’ button in some screens) will submit your new  setting into the bridge and will take effect immediately.    System As
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  manage other connected Slave EPs. The HCNA MAC exists only in HCNA (coax) domain, and is unaware for any  EP end-user. System manager use system IP address and Ethernet MAC address to access HP-51M. Each HP-51M  device should be stamped with both Ethernet MAC and HCNA MAC for identification.    Figure 4: EP Management Architecture    Firmware/Driver Files  HP-51M flash ROM is capable of storing the following files:  1. System bootcode (OS bootl
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide    Each row represents for one EP, here we have one Master (Local) HCNA device (on the top) and 7 extra Slave EP  devices shown on the window. The first two are EPs based on 3010, follows three Smart EPs based on 3110 (or  called Configurable EPs), and the last two EPs that are powered off.    Smart EP  Denote an EP whose Ethernet properties are configurable. Based on 3110 chipset, with built-in simple management  function, its Ethernet settings
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  Config  : configure Master’s/Smart EP’s both HomePNA and Ethernet properties or EP’s sole HomePNA  properties.    Del        : Delete the off-line EP’s profile, to save the EP properties profile space of HP-51M.    Test      : run the built-in diagnostic functions.  Refer “Diagnosis” for more details.    Click on each device’s ‘HPNA’ button can open the window to configure its HomePNA properties. Click on ‘Ether’  button to configure its Ethern
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  HCNA driver with the new values (replace the running working values with the new setting ones) before any  connected EP can access the network controlled by HP-51M.    Privacy Mode Usage Example  For example, first activate the ‘Privacy Mode’ by apply the ‘ON’ setting and change the ‘Privacy Key’ to ‘0x1234’.  HP-51M will request to upgrade the Master’s HCNA driver, and all allowable EP’s HCNA driver.    Click the ‘Apply’ button will change the
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide      Here we have one banned EP shown in red background after upgrade,      Then power on the 2 extra off-line EPs, they will also be banned since their ‘Privacy Mode/Key’ (as default  ‘OFF’/‘0x0’) doesn’t match with the Master’s (now key is ‘ON’/‘0x1234’ ).  11                                                                                                                                                                                           
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide    EPs are classified by the shown background color, green for allowed EP, red for banned EP.    Privacy Mode/Key Summary  EP can’t communicate with each other regardless of the settings of ‘Privacy Mode’ and ‘Privacy Key’. EP could  access the coax network controlled by HP-51M only if EP has the right ‘Privacy Mode’ and ‘Privacy Key’. Please  refer the following diagram for more details,                      Master  Privacy Mode  On Off  EP  Pr
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide  Yellow: For Master, it has inconsistent ‘Privacy Mode/Key’ settings. You may upgrade the Master’s driver to  synchronize its working values. (to replace the running working values with the setting ones).  Red:      For banned EP, either ‘Privacy Mode/Key’ in EP is not matched or the ‘Host Limit’ value in EP is 0. HP- 51M will refuse to serve this EP.    EP HomePNA Properties (HPNA)  EP (either Smart or not) conforms to the following HomePNA set
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        DYNAMIX HP-51M Coax MDU Master Bridge User’s Guide      Service and Speed/Duplex  Change ‘Service’ to enable or disable the port. This setting open or close the related Ethernet switch port in EP.  Default setting in field ‘Speed/Duplex’ is ‘Auto’ states for auto-negotiation.    Bandwidth Control  Consider port HCNA as the network backbone and refer the following diagram to set up bandwidth control  parameters in EP’s Ethernet switch (Regards as Hardware bandwidth control, works for both upstrea