Streszczenie treści zawartej na stronie nr. 1 
                    
                         
 
KOBE Brand Range Hood 
 
 
Model No.: CH0130SQB 
CH0136SQB 
CH0142SQB 
CH0148SQB 
 
CH-101 SERIES – 18” HEIGHT 
 
INSTALLATION INSTRUCTIONS 
AND OPERATION MANUAL 
                                                                                                                                                                                                                                                                                                                                             
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                            - READ AND SAVE THESE INSTRUCTIONS -          CONTENTS   IMPORTANT SAFETY INSTRUCTIONS.................................................................................... 1  COMPONENTS OF PACKAGE ................................................................................................. 3  INSTALLATION ......................................................................................................................... 4  UNDER THE CABINET INSTALLATION ..............................
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                          IMPORTANT SAFETY INSTRUCTIONS      - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -    WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL  INJURY, OBSERVE THE FOLLOWING:    1) Installation and electrical wiring must be done by qualified professionals and in accordance  with all applicable codes and standards, including fire-rated construction.  2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or  other hidden utilities.  3) Duc
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                          What to Do In The Event Of a Range Top Grease Fire    - SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the  burner.  KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES.  If  the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE  DEPARTMENT or 911.  - NEVER PICK UP A BURNING PAN – You May Get Burned.  - DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.  - Use an extinguisher ONLY if:  1) Yo
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                            COMPONENTS OF PACKAGE    (Must keep all material for returns or refunds)      RANGE HOOD BOX       KOBE Range Hood – 1                           	   Warranty Registration Card –1    Instructions Manual – 1   Baffle Filter   - 2 (30”, 36”, 42”)                          - 3 (48”)     Stainless Steel Spacer                            - 0 (30”)  - 1 (36”)  - 2 (42”, 48”)  3/16" X 3/8" (8 pc)      Oil Tunnel – 1   Ducting Transition – 1   DUCT COVER KIT (Sold Separately)   Screw Package
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                              INSTALLATION    PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING    Calculation before Installation    To calculate installation, please refer to Table 1. (All calculation in inches.)    - FOR UNDER THE CABINET -    TABLE 1    A = Height of Floor to Ceiling  B = Height of Floor to Counter Top    (Standard: 36”)  C = Preferred Height of Counter Top to Hood  Bottom (Recommended 27” to 30”)  [(A – B) – (D + E)]  D = Height of Hood  E = Height of the Cabinet                 - FOR STAND ALONE (
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                            SAFETY WARNING  HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF  REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.    NOTE: USING ELECTRICAL SCREWDRIVERS MAY CAUSE DAMAGE TO THE HOODS.      Installation Table of Contents    UNDER THE CABINET INSTALLATION................................................................................6  Preparation Before Installation................................................................................................6  Hood
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                          UNDER THE CABINET INSTALLATION    Preparation Before Installation  NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT    DEBRIS FROM ENTERING THE VENT  OPENING.    • Decide the location of the venting pipe from the hood to  the outside.  Refer to Figure 1.    • A straight, short vent run will allow the hood to  perform more efficiently.    • Try to avoid as many transitions, elbows, and long runs                          Figure 1  as possible.  This may reduce the performance of the  hood.    • Tempo
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                              Ductwork Installation      7. Use 8” aluminum or steel pipe (follow building codes in  your area) to connect the ducting transition on the hood    to the ductwork above.  Use duct tape to seal and  secure joints as shown in Figure 5.      Wiring to Power Supply     S AF E T Y W AR N I N G  TO PREVENT THE RISK OF ELECTRICAL SHOCK OR                         Figure 5  INJURY, ALL RANGE HOODS SHOULD BE PROPERLY  GROUNDED AND INSTALLED BY A TRAINED    PROFESSIONAL WHO IS KNOWLEDGEABLE ABOUT  AP
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                            15. Install heating lamps (not provided), 120 Volts 250  Watts max. each.          16. Turn power ON in control panel.  Check all lights and  fan operation.      17. Make sure to leave this manual for the homeowner                                           Figure 8          8                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                          STAND ALONE INSTALLATION    ***Follow these installations only if installing with an optional duct cover:      Preparation Before Installation    NOTE: TO AVOID DAMAGE TO YOUR HOOD,   PREVENT DEBRIS FROM ENTERING THE    VENT OPENING.          • Decide the location of the venting pipe from the    hood to the outside. Refer to Figure 9.    • A straight, short vent run will allow the hood to    perform more efficiently.      • Try to avoid as many transitions, elbows, and long                    
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                              2. Align hood-mounting bracket to the two screws  WALL on the wall and hook hood into place.  Tighten  screws to secure hood to the wall.    3. For safety purpose, extra knockout holes on the  back of the hood are provided for a more secure  installation.  Knock out as many holes as needed  and secure with screws (not provided) from the  inside of hood.     CAUTION: MAKE SURE HOOD IS SECURE  BEFORE RELEASING.                                Figure 13          Wiring to Power Supply       SA
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                            Duct Cover Installation        5. Use 8” aluminum or steel pipe (follow building    codes in your area) to connect the ducting    transition on the hood to the ductwork above.     Use duct tape to seal and secure joints as shown    in Figure 15.  Slide the duct cover onto the hood.         6. Use 3/16” x 3/8” screws (provided) to attach duct    cover to hood.                              Figure 15          Final Assembly  CAUTION:  Install heating lamps last.    7. Drop Oil Tunnel into suppo
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                            OPERATING INSTRUCTIONS    This KOBE hood is equipped with touch-sensor screen and features 3 minute delay shutoff,  powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen lights and  heating lamp capability (heating lamps not included).  The touch-sensor screen has Heat Lamp Control, Light Control, Speed Control  (QuietMode™, Low, Medium and High), and Power Control.  Refer to Figure 18.  Heat Lamp Light Control Speed Control Power Control                     
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                          Turn Off After 3 Minute Delay  Gently touch the symbol under the Power Control sign once,  the symbol flashes and after 3 minutes, the hood will turn off leaving only  the sign lit.     Speed Control:  • There are four speeds: QuietMode™, Low, Medium, and High.  To activate the speed, touch  the control under the speed sign.  For example, if turning on hood at low speed, gently touch  the symbol under the sign.  If you want to switch from low to high speed, touch  the symbol under the sign and
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                            MAINTENANCE      SAFETY WARNING  NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS  OPERATING.      For optimal operation, clean range hood surface and stainless steel baffle filters regularly.      Cleaning Hood Surface    CAUTION:  NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.    Regular care will help preserve the appearance of the hood.    1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth.  2) If hood looks splotchy (stainless steel hood), use an or
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                            Cleaning Stainless Oil Tunnel, Baffle Filters and Spacers    CAUTION:  DRAIN OIL BEFORE RESIDUE CAN OVERFLOW.      1. Remove the baffle filter (reverse the order of baffle installation).  2. Carefully remove oil tunnel.  3. Discard oil and residue.  4. Wash oil tunnel, baffle filters and spacers with warm soapy water.    5. Dry thoroughly and put back.    NOTE: Oil Tunnel, baffle filters and spacers are top rack dishwasher safe.      Replacing Light Bulb    CAUTION:  HALOGEN LIGHT UNIT MAY B
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                            SPECIFICATIONS    MODEL / SIZE CH0130SQB / 30“  CH0136SQB / 36“  CH0142SQB / 42“  CH0148SQB / 48“  COLOR #304 Commercial Grade Stainless Steel  CONSUMPTION / AMPERE 900W / 8A  VOLTAGE 120V 60Hz  NUMBER OF MOTORS 1  DESIGN 18 Gauge Seamless / Satin Finish  FAN TYPE: CENTRIFUGAL Squirrel Cage  EXHAUST Top Transition Rectangular to 8” Round x 1  CONTROLS Touch Sensor Screen  HALOGEN LIGHTS 30” / 36” /42” - 12V20W x 2  48” - 12V20W x 3  HEATING LAMPS 120V 250W Max. x 2 (Light Bulbs Not Included)
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        8" (203) 2 - 1/8" (54) 1 - 7/8" (48)  1/ " (12 2 ) 1 - 1/4" (32) 6 - 1/2" (166) 4 - 1/2" (114) 1" (25) 12" (305) 24" (610)     MEASUREMENTS & DIAGRAMS    *** Inch measurements converted from millimeter.  Inch measurements are estimated.    - FOR UNDER THE CABINET -  MODEL NO: CH0130SQB  CH0136SQB  CH0142SQB  CH0148SQB              17  6 - 1/2" (165) 1 - 1/4"(32)  1 " ) 1 - /4 (32 12" (306) 1 - 1/4" (32) 3 " 36 4 " / 48" 0 / " / 2  18" (457) 3 - 1/8" (79.5)