Streszczenie treści zawartej na stronie nr. 1 
                    
                         
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
GLX390 Hood 
 
 
Instructions Manual 
 
 
 
 
www.rangemaster.co.uk 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Instructions Manual  INDEX  RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................3  CHARACTERISTICS..............................................................................................................................................................4  INSTALLATION ...................................................................................................................................
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        RECOMMENDATIONS AND SUGGESTIONS   The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your  specific appliance.  INSTALLATION  • The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation.   Check that the mains voltage corresponds to that indicated on the rating plate  fixed to the inside of the hood.   For Class I appliances, check that the 
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        CHARACTERISTICS  Dimensions            4  EN 4    	 				
	                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Components   		  Ref. Q.ty  Product Components  1  1  Hood Body, complete with: Controls, Light,  Blower,     Filters  2.1  1  Upper Section   	 2.2  1  Lower Section    8  1  Directional Air Outlet grille  9  1  Flange    	 10 1 Adapting ring ø 120-125 mm   14.1 2 Air Outlet Connection Extension    15 1 Air Outlet Connection  16  1  Filter cover  Ref.  Q.ty  Installation Components   7.2.1  2  Upper Chimney Section Fixing Brackets   7.3 1 Air Outlet Connection Support 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        INSTALLATION  Wall drilling and bracket fixing  7.2.1 7.3 200 200 11a 1 1 180 180 2 2 11 12a A=Min 250       Max 400    On the wall, draw  • a Vertical line up to the ceiling or upper limit, at the centre of the area in which the Hood is  to be fitted;   a Horizontal line at a minimum of  (710 mm + A) above the Cooker Top.    Mark a point (1) on the horizontal line, 200 mm to the right of the vertical reference line.   Repeat this operation on the other side, checking that the two marks are l
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Mounting the hood body   Open the ducting panels.   Disconnect the panel from the hood canopy by slid- ing the fixing pin lever.(A)   Remove the metal grease filters by turning the han- dles provided.   Adjust the two screws Vr, on brackets 11a, to a mini-  mum.(B)   Hook the hood canopy onto the two brackets 11a.    From inside the hood canopy, adjust the screws Vr to  set the Hood Canopy level.   Tighten the safety screw 11.     Connections    DUCTED VERSION AIR EXHAUS
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        	  	 RECIRCULATION VERSION AIR OUTLET   Insert the connection extension pieces laterally 14.1 in connec- tion 15.  
  Insert the Connector 15 into the Support bracket 7.3 and fix it  with a screw.   Make sure that the outlet of the extension pieces 14.1 is hori- 	 zontally and vertically aligned with the chimney outlets.    Connect the air outlet connection 15 to the hood body outlet  using either a flexible or rigid pipe   ø 150 mm, the choice of  which is left to the installer.  
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        USE  Control Panel   The hood can be switched on pushing directly onto the requested speed without firstly having  to select 0/1 button.   KEY  LED FUNCTIONS    L 0/1 Light  Turns lighting on and off.   T1 0/1 Motor on  First speed.        When pressed for about 1 seconds the motor   is switched off.      Flashing 24h Changeover         This is enabled by pressing and holding  the button for approximately 5".It al-  lows a suction level of 100 m3/h with a  noise level of just 28dB(A).Can 
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        MAINTENANCE  REMOTE CONTROL (OPTIONAL)  The appliance can be controlled using a remote control powered  by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type.   Do not place the remote control near to heat sources.   Used batteries must be disposed of in the proper manner.    Ducting  panels   Open the ducting panels.   Disconnect the panel from the hood canopy by sliding the fix- ing pin lever.   Clean the outside using a damp cloth and neutral liquid deter- gent.   Cle
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Grease filters  CLEANING METAL SELF- SUPPORTING GREASE FILTERS  Alarm signal reset   Switch off the lights and extractor motor.    Press button T3 for at least 3 seconds, until the leds start to  flash.    Cleaning the filters   The filters are washable and must be cleaned when the LED S1  lights up or at least every 2 months of operation, or more fre- quently for particularly heavy usage.   Remove the filters one at a time holding them up with one  hand and pulling the handle downwards with
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        Activated charcoal filter (Recirculation version)  The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes  or at least every 4 months. The alarm signal will only light up when the extractor motor is  switched on.  Alarm signal activation   In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or  at a later date. Turn the Lights and the suction Motor off.   Disconnect the Hood using the Main switch or the double-pole s
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                             AGA RANGEMASTER LTD.        436004184_ver1