                        READ AND SAVE THESE INSTRUCTIONS 
OPERATING 
 PN 99515 
MANUAL 
S OE PR EV NI C RE E F RR EIF GR EIR GA ET RE AD T E SD E L / F N -O SE NR -R VE IC FE R IM GE ER RC AH TE AD N D M IS EE RR C HANDISER 
Model RB5C4848LR   48”L* x  38 1/8”D** x 47 1/4”H 
Model RB5C5948LR   56”L* x  38 1/8”D** x 47 1/4”H 
Model RB5C7748LR   77”L* x  38 1/8”D** x 47 1/4”H 
Model RB5C4848RR   48”L* x  38 1/8”D** x 47 1/4”H 
Model RB5C5948RR   56”L* x  38 1/8”D** x 47 1/4”H 
Model RB5C7748RR   77”L* x  38 1/8”D** x 47 
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        TABLE OF CONTENTS  3  OVERVIEW AND WARNINGS .. .…………………………..…………………..…….………….....…..      MERCHANDISER SET-UP  ………….. …..….…………………...………...…..……………………… 4      5  START-UP AND OPERATION ...…………….. …..….…………………...………...…..………………     6  MAINTENANCE FUNDAMENTALS ……………………………………………………………..………      8  ELECTRICAL FUNDAMENTALS ……………. …..….…………………...………...…..………………      11  REFRIGERATION FUNDAMENTALS …………………….………………………………………..…...       12  TECHNICAL DATA  ………………………………………………………………………………….……     15  ILLUST
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        OVERVIEW AND WARNINGS   OVERVIEW    • *The Structural Concepts Renaissance refrigerated service cases are designed to  merchandise packaged bakery products at 5° Celsius  / 41° Fahrenheit  or less product  temperatures.   • These cases should be installed and operated according to the following instructions to  insure proper performance.   • This unit is designed for the display of products in ambient store conditions where  temperatures and humidity are maintained at a maximum of 24° C / 75° F 
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        SET-UP   Merchandiser Set-Up    • Mobile Units (Cases with Casters)    • For your safety, the equipment is fur- nished with a properly grounded cord  connector.  Do not attempt to defeat the  grounded connector.  • Plug cord into a certified electrical outlet  with ground.     • Stationary Units    • Self-contained refrigeration.  Note:  Servicing to be accomplished by  refrigeration / electrical contractor.   Rear Grill  • Removing the rear grill will expose ac- cess to the a 3” service opening
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        START-UP AND OPERATION   Raise the Curved Glass   Front Curved Glass    Lift Handle  • To raise the front curved glass, grab the lift  Coil Fan  handle extrusion on the bottom edge of the  front curved glass and lift up.  • Gas cylinders hold the glass open for hands  Deck Pan  free access to the interior of the case.    Register  Merchandiser Start-Up    • Turn on the main power. Switch is on the  control panel at the rear right hand side of  base.  Supply power will start evaporator coil  fan(
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        MAINTENANCE FUNDAMENTALS  • Preventive Maintenance should be per- formed every 30 days unless conditions  warrant a more frequent replacement cy- cle. Air Filter      Air Filter    • Magnetic strips attached to the filter adhere  the filter to the rear grill.  • The nylon mesh filter can be cleaned by rins- ing thoroughly with water against the air flow  direction.  A mild detergent removes smoke/ grease stains.    Rear Ledge Removal    1. Pull ledge back to stops.  2. Rotate down to the vertica
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        MAINTENANCE FUNDAMENTALS  Shelf Assembly Removal    • Raise the front curved glass.  Cap  • Remove and carefully set aside glass or wire  shelves.  Plug  • For lighted shelving, unplug the light cord  and detach from the rear shelf support.  • Slide light assembly back to unlock, then ro- tate up to separate from brackets.  • Slide rear support back to unlock and rotate  Receptacle  up to separate from brackets.  • Remove brackets.  Note, it may be neces- sary  to remove  the nylon shipping  bra
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        ELECTRICAL FUNDAMENTALS   Warning, disconnect power before providing  maintenance and service to unit.    Ballast Access/Removal     • Assembly or disassembly  and servicing  to be accomplished by licensed electrical  contractor.   • Remove the rear grill by removing the six  screws located on both sides of the grill.  • Remove the control panel by removing the  three remaining screws located on the right  side of the panel.  Rear Grill  • Release quick disconnect from wire har- ness.  • Remove 
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        ELECTRICAL FUNDAMENTALS   Warning, disconnect power before provid- ing maintenance and service to unit.  Coil Fan    Evaporator Fan Access    • Raise the front curved glass.  Deck Pan  • Shelving can be removed to facilitate main- tenance   • Turn off the electrical power at main  power switch if servicing fans.   • Remove deck pans to access coil fans.   • Remove mounting screws from fan assem- bly to separate fan from shroud.      Front Condensate Fan  Lower  Front Panel  Upper Front Panel Ass
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        ELECTRICAL FUNDAMENTALS   Warning, disconnect power before providing  maintenance and service to unit.    Bracket Screws   Front Fan Access    The front fans supply air flow to the top of the  front panel louvers. This air flow is to eliminate  any condensation formed on the face of the  curved glass.     • Fan/s are located behind the front panels.   • Turn off the main electrical power at  main power switch if servicing fans.   • Remove the lower front panel.  • Remove screws from the lower fl
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        REFRIGERATION FUNDAMENTALS   Temperature Settings     • Assembly or disassembly  and servicing  to be accomplished by licensed  electrical / refrigeration contractor.  • The case temperature is set at the factory,  as determined by the case size.     Refrigeration:  Access, Connections &  Servicing    • Assembly or disassembly  and servicing  to be accomplished by licensed  refrigeration contractor.   • Service connections are located on the  Condenser Frame  compressor / condenser assembly.  • 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        TECHNICAL DATA    Electrical Ratings   RB5C4848R RB5C5948R RB5C7748R   Self-Contained      Incoming Supply 120/1/60 120/1/60 120/1/60   Min. Circuit Amps 15 15.0 15.0   Amps  9.58 11.03 11.03   Watts 1150 1324 1324   Hook-Up Leads or Cord w/ Leads or Cord w/ Leads or Cord w/  Nema 5-15 P Nema 5-15 P Nema 5-15 P  Electrical Controller Electrical Control- Electrical Control- Electrical Controller    ler ler  Lighting   RB5C4848R RB5C5948R RB5C7748R   Lamp Quantity 8 8 8   Lamp Type F15 T8 F17 T8 F
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        TECHNICAL DATA    Control Settings—RB5C4848R  Mechanical  Mechanical Settings   Pressure Settings – S/Contained   Differental  60  High Side Cut-In  260  Superheat 8-10  Control Settings Electronic Controller  Set Point (Supply Air) SP 22 Maximum Defrost Duration dd  45  Hysteresis HY  9 Dripping Time dC  0  Low Setup Stop LL  20 First Defrost After Power On dU  OF  High Setup Stop HL 50 Display During Defrost dP  0  Anti-Short Cycle Delay CC  3 Display Delay After Defrost dr  20  Deep Freezing 
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        TECHNICAL DATA    Control Settings—RB5C7748R  Mechanical  Mechanical Settings   Pressure Settings – S/Contained   Differental  60  High Side Cut-In  260  Superheat 8-10  Control Settings Electronic Controller  Set Point (Supply Air) SP 27 Maximum Defrost Duration dd  45  Hysteresis HY  4 Dripping Time dC  5  Low Setup Stop LL  20 First Defrost After Power On dU  OF  High Setup Stop HL 50 Display During Defrost dP  0  Anti-Short Cycle Delay CC  3 Display Delay After Defrost dr  20  Deep Freezing 
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        ILLUSTRATED  PARTS BREAKDOWN    1  2  3  22  4  21  5  20  19  6  18  17  7  16  8  15  9  14  13 10  12  11  R 888 Porter Rd.  Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com  15                                                                                                                                                                                                                                                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        ILLUSTRATED  PARTS BREAKDOWN    23  24  35 34 33  25  26  27  28  32 31 29 30 R 888 Porter Rd.  Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com  16                                                                                                                                                                                                                                                                                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        PARTS LIST  1 Curved Glass 19 Bulb Seal  2 End Panel Full 20 Clam Shell Assembly  3 End Panel Mirror 21 Thermometer  4 Lift Handle 22 Glass or Wire Shelf  5 Shelf Light 23 Rear Door, Right  6 Lamp 24 Rear Door, Left  7 Deck Pan 25 Ledge Hinge  8 Bumper Insert 26 Evaporator Pan  9 Bumper End Cap 27 Ballasts  10 Lower Front Panel 28 Control Panel   12 Front Panel 29 Rocker Switch  14 End Panel Cutaway 30 Johnson Control  15 Fan Motor, Evaporator 31 Electrical Panel Plexi Cover.  16 Insulated End G
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        TROUBLESHOOTING   Product is Drying Out Check the relative humidity in the store.  Water on the Floor Check that all of the hoses are connected.   Check that  the drain trap is free of debris.   Is the evaporator pan positioned correctly under drain.   Is the evaporator pan plugged in and heating properly.   Excessive Fan Noise Check that the case is aligned, level and plumb.   Check that nothing is obstructing the blade rotation.   Check that the fan shroud is properly secured.  System is not O
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        WIRING DIAGRAM RB5C (48/59/77) 48 LR & RR Units SELF CONTAINED   R 888 Porter Rd.  Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com  19                                                                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        WIRING DIAGRAM RB5C (48/59/77) 48 LR & RR Units REMOTE   R 888 Porter Rd.  Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com  20