Streszczenie treści zawartej na stronie nr. 1 
                    
                         
A Div of ITW FEG, LLC. 
 
 
 
 
INSTRUCTION MANUAL 
 
 
 
 
 
 
 
 
KRES  
Equipment Stands 
Self-Contained and Remote 
 
 
 
Kairak   IM-ES-REV 5-09-06 
500 S. State College Blvd. 
Fullerton, CA  92831  PN 4406010-1 
                                                                                                                                                                                                                                                                                        
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        KAIRAK  Page 2     GENERAL    Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to  120 inches long.  These units are available as a refrigerated or freezer storage compartment.   The condensing systems are designed to be installed with minimal clearance to walls or other  equipment.      These models are available as self-contained or remote. Standard features on these models  include electronic temperature control, all stainless steel construction (galv
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        KAIRAK  Page 3    LOCATING THE EQUIPMENT  All model lengths can be installed with minimal clearance at the back and sides of the units      INSTALLING PARTS SHIPPED LOOSE      COMPRESSOR FILTER  Remove louvered panel by lifting up and pulling out entire panel.  Slide the filter into the tracks  located below the compressor compartment.  Be careful not to catch the filter on sharp edges  when installing.  Replace louvered panel by installing top of panel into track and pushing in the  bottom so t
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        KAIRAK  Page 4          ELECTRIC CONDENSATE EVAPORATOR  Some units may come with the electric condensate evaporator shipped loose.  To install, attach  the two (2) mounting rails to the bottom of the cabinet with 4 or 6 (depending on the model) #6- 32 x 3/8 phillips head screws.  Place the condensate evaporator in the heater bracket.  Slide the  heater bracket into the mounting rails.  Plug the electrical cord into the heater and the electrical  outlet.  NOTE:  Drain should be located above the 
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        KAIRAK  Page 5      REFRIGERATION LINES (Remote Units)    WARNING:   REFRIGERATION LINES ARE SHIPPED UNDER PRESSURE.  USE CAUTION  WHEN OPENING LINES.     On remote units, refrigeration lines for suction and supply are located on the back of the unit  near the bottom. The suction line is marked “Suction” and is 3/8” copper tubing. The supply line  is 1/4” copper. See “Electrical Connections” section for wiring instructions.    If no holding charge is evident upon opening lines, contact Kairak Se
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        KAIRAK  Page 6      PRESTART CHECKS    DEFROST TIME CLOCK SETTINGS   All models have a defrost time clock that is set to defrost 3 times a day for a 15 minute time  period.  The defrost settings are factory set at 12:00 a.m. to 1:00 a.m., 2:00 a.m. to 2:30 a.m.  and 5:00 a.m. to 6:00 a.m.  To change this setting, set the pins to desired off times.  Each pin  represents 15 minutes. Pins pulled out away from center of time clock represent refrigeration  off.  Pins pushed toward center indicate ref
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        KAIRAK  Page 7      TEMPERATURE CONTROL SETTINGS  All temperature settings are preset at the factory but local conditions may necessitate slight  adjustments.    On self-contained refrigerated models the temperature control (shown in Fig. 5) is located in the  compressor compartment.               Base Temperature  Control  Power Switch      KRES Self-contained    Fig. 5                                    - 7 - IM-ES-REV 5-09-06.doc5-09-06                                                         
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        KAIRAK  Page 8      On remote models, the controls can either be inside the control cabinet similar to that shown in  Fig. 5 or inside the refrigerated base as shown in Fig. 6.        Base  Temperature  Control      KRES Remote     Fig. 6          On both self-contained and remote refrigerated units, the temperature control should be set at  37°F with a 3°F differential.  This display should read between 34°F and 40°F.  The temperature  control setting is “locked” to avoid unauthorized adjustmen
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        KAIRAK  Page 9    OPERATION    A thermometer is provided on all refrigerator and freezer cabinets.    Allow cabinet to reach normal operating temperature before loading (approximately 1 hour).      The refrigerated storage cabinet is designed to maintain temperatures between 33°F and 40°F,  or –2°F to 2°F for a freezer storage cabinet. If the base is overloaded with warm food products,  a certain amount of time is required to remove heat from items before operating temperatures  can be maintaine
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        KAIRAK  Page 10    Liner Lock  Black  Clamping  Cross Rail Lock  Knob  (1 on each side  of drawer)      Fig. 7              Drawer Module  Cross Rail    Lock    Black  Clamping  Knob      Fig. 8                  - 10 - IM-ES-REV 5-09-06.doc5-09-06                                                                                                                                                                                                                                                             
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        KAIRAK  Page 11    CONDENSING UNIT    WARNING:  DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY  PARTS ON THE UNIT.    The condensing unit coil and filter must be cleaned regularly on self-contained models for  optimal performance.  The operating environment will affect the required frequency of cleaning.   However, both should be cleaned a minimum of once every three months.  Air must be able to  freely circulate through the condenser. Unit performance and operating efficiency are  signi
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        KAIRAK  Page 12      TROUBLESHOOTING    SYMPTOM POSSIBLE CAUSE  Compressor fails to operate. • Power failure.  • Plug loose in receptacle or unplugged.  • Blown fuse or tripped circuit breaker.  • Main power switch is Off.  • Temperature controls or time clock not set  properly.  Compressor operates for prolonged periods  • Door gaskets not sealing properly.  and/or continuously.  • Condensing unit filter is dirty.  • Evaporator coil is iced up or dirty.  • Prolonged and/or frequent door opening
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        KAIRAK  Page 13                                                                                A Div of ITW FEG, LLC.       1-YEAR LABOR WARRANTY    Kairak warrants that equipment manufactured by Kairak will be free from defects in  material and workmanship for a period of 1-year beginning 30 days after ship date.  All work  must be pre -approved by the factory to qualify for reimbursement under this warranty.  Unapproved labor claims will not be paid. Note: t-stat and time clock adjustments are