                        INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
POWER-VENT 
HIGH-EFFICIENCY 
FIREPLACE WITH 
BAY WINDOW
MODELS
PV-28SV50-(BN,BP)-1
PV-28SV55-(CN,CP,GN,GP)-1
™
Installer: Leave this manual with the  EFFECTIVE DATE
appliance.
MAY 2007
Consumer: Retain this manual for future  
reference.
WARNING: If the information in these in-
structions are not followed exactly, a fire or ex-
plosion may result causing property damage, 
personal injury or loss of life.
This appliance is NOT to be installed in Canada.
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        TABLE OF CONTENTS SECTION PAGE Important Safety Information  ......................................................................................................................................... 3 Safety Information for Users of LP-Gas  ......................................................................................................................... 4 Requirements for Massachusetts  .......................................................................................................
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be lo- • Installation and repair should be done by a QUALI- cated out of traffic and away from furniture and draper- FIED SERVICE PERSON. The appliance should be in- ies. spected before use and at least annually by a qualified  service person. More frequent cleaning may be required  • Children and adults should be alerted to the hazar
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and bers of your household. Someday, there may not be a minute to  explosions. In its natural state, propane is odorless and colorless. lose, everyone’s safety will depend on knowing exactly what to  You may not know all the following safety precautions which can do. If, after reading the following information, you feel you still  protect both you and your family from an accident. Read them need more i
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be  in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a  for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line  Commonwealth and where the side wall exhaust vent termination with the exhaust vent t
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        GAS SUPPLY Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ Installing a New Main Gas Cock CGA-B149 (.1 or .2) installation code. Each appliance should have its own manual gas cock. A manual main gas cock should be located in the vicinity of the  Recommended Gas Pipe Diameter unit. Where none exists, or where its size or location is not ad- Pipe Length Schedule 40 Pipe Tubing, Type L  equate, contact your local authorized installer for installation or  Inside Diameter Outside Diamete
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        INTRODUCTION Introduction Qualified Installing Agency Always consult your local Building Department regarding regu- Installation and replacement of gas piping, gas utilization equip- lations, codes or ordinances which apply to the installation of a ment or accessories and repair and servicing of equipment shall be  direct vent wall furnace. performed only by a qualified agency. The term “qualified agen- cy” mean any individual, firm, corporation or company which  Instructions to Installer either in 
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION 1. This installation must conform with local codes or, in the ab- Note: Under no circumstances should the appliance be in- sence of local codes with NFPA54. stalled under conditions which would not allow for  easy removal of the appliance to carry out routine  2. Provide adequate clearances around the product for servic- inspection and service to the appliance, to do so will  ing and ensure there are no obstructions to the combustion  void t
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        CLEARANCES FOR DIRECT VENT 1. Pick a location on a wall with a clear space in the room. In The bottom of the exhaust vent terminal and the air intake shall  selecting a location for installation, it is necessary to provide be located at least 12” (305mm) above grade and must be vented  adequate accessibility clearances for servicing and proper outside. installation. Be sure to locate the unit close enough to a 110  WARNING: The nearest point of the vent cap should be  VAC wall receptacle to prop
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        CLEARANCES FOR SINGLE FLUE The bottom of the exhaust vent terminal and the air intake shall  1. Pick a location on a wall with a clear space in the room. In  be located at least 12” (305mm) above grade and must be vented  selecting a location for installation, it is necessary to provide  outside. adequate accessibility clearances for servicing and proper  installation. Be sure to locate the unit close enough to a 115  WARNING: The nearest point of the vent cap should be a  VAC wall receptacle to
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        SPECIFICATIONS Heater with Pedestal and Single Flue Adaptor 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required) Figure 3 22618-12-0707 Page 11                                                                                                                                                                                                                                                                               
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        SPECIFICATIONS - (continued) Heater without pedestal 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required) Figure 4 Page 12 22618-12-0707                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        SPECIFICATIONS - (continued) Fireplace Insert with Mantel Surround with Slim Top Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 7 Top Cover Kit, Slim Model #PV2H Caution: Do not block louver in surround. Note: Verify fireplace opening dimensions using Figure 9, page 15. Figure 5 22618-12-0707 Page 13                                                                              
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        SPECIFICATIONS - (continued) Fireplace Insert with Mantel Surround with Short Top Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 8 Top Cover Kit, Short Model #PV4H Caution: Do not block louver in surround. Note: Verify fireplace opening dimensions using Figure 9, page 15. Figure 6 Page 14 22618-12-0707                                                                            
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        CLEARANCE TO COMBUSTIBLES Freestanding Models A B B C C Figure 7 Figure 8 Freestanding Units A Rear Wall to Heater 0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability) B Side Wall to Heater 0” (4” recommended for serviceability) C Corner Installation 0” D Mantel Clearance See Figure 11 Fireplace Insert CEILING 8” 6” COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 40 ” 4” 24 ” 18 ” 12 ” Single Flue Requires surround for combustion air. Do not cover surround louver. Figure 9 Mantel an
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        ROUGH FRAMING DIMENSIONS A  - 13 /34” MIN. CO-LINEAR   8 1/2” WHEN USING DIRECT VENTING   PVVK-24H/PVVK-48H NOTE: DIMENSIONS FOR USE WITH SHORT TOP  PV4H. THIS IS RECOMMENDED FOR UNIT  SERVICEABILITY. B - 25 1/8” C - 28” NOTE: IF TRIM AROUND HEATER IS NECESSARY,  THE SURROUND KIT PVE-1 MUST BE USED,  AND SUBTRACT 1” FROM (A) DIMENSION. Figure 12 INSERT INTO MASONRY FIREPLACE A - 12 3/4” MIN. SHORT TOP PV4H   17 13/16” MIN. SLIM TOP PV2H   USING PVE-1 SURROUND KIT B - 25 1/8” MIN. DIRECT VENT   2
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        WALL CLEARANCES Figure 14 22618-12-0707 Page 17                                                                                                                                                                                                                                                                                                                                                                                                                                                                     
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        LOG SET INSTALLATION INSTRUCTIONS Log Installation All Logs The gas log set (front left log, front right log, center log and rear  The positioning of the logs is critical to the safe and clean opera- log) is pre-set and installed in the factory. Only the top left log and  tion of this heater. Sooting and other problems may result if the  top right log are packaged separately inside the firebox for instal- logs are not properly and firmly positioned in the appliance. lation by the installer. 6. Pri
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        VENT EXAMPLES FOR SINGLE FLUE Max Vent Run - 40ft. Equivalent With Three (3) 90° Elbows Special Note: The vent terminal 90° elbow and first 90° elbow off back of the heater, when within 6” (15.2cm), do not contrib- ute to the overall vent length measurement. For each 45° elbow installed in the horizontal run, the length of the horizontal run  MUST be reduced by 1.5 feet (45cm). This does not apply if the 45° elbows are installed on the vertical part of the vent system.   Reduce the length of the 
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        VENT EXAMPLES FOR SINGLE FLUE (cont.) V =  40’ Total =  40’ Figure 20 Venting for Existing Fireplace Installation H =  36’ V =  1’ (1) - 90° =  3’ Total = 40’ SINGLE FLUE ADAPT OR MODEL #PVVK-SH Figure 21 Single Flue - Venting with Shroud Installed Figure 19 Shroud Kit Model# PVSH Single Flue - Vertical Vent Run Page 20 22618-12-0707