Streszczenie treści zawartej na stronie nr. 1 
                    
                        ▪ ▪ ▪ ▪ ▪
F R E E
SAFETY
GUARD
PROTECTS AGAINST BURNS
▪ ▪
See Page 2 For Details
CARE AND OPERATION INSTRUCTIONS
B-Vent Gas Fireplaces 
MLBV 35/40 Models
P/N 506017-03   Rev. B   06/2011 
MODELS
This manual is one of a set of two supporting this product.  
Refer to P/N 506015-04 for Installation Instructions.
MILLIVOLT: ELECTRONIC:
Ce manuel est disponible en francais, simplement  
en faire la demande. Numéro de la pièce 506223-22.
MLBV-35NM MLBV-40NM MLBV-35NE
MLBV-35PM MLBV-40PM MLBV-40NE
WHAT
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual.  Safety and   Pay special attention to all warnings and safety information. Following these safety, care, and operation instructions will help  Your Fireplace ensure many years of dependable and enjoyable service from  your fireplace. All parts of
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS [FRENCH] [SPANISH] La sécurité et Seguridad y   votre foyer su chimenea Toutes les parties de votre foyer ¡Todas las partes de la chimenea  Lennox Hearth Products deviennent Lennox Hearth Products se ponen  EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  Afin d'éviter de vous brûler gravement ou de  Instale una malla o barrera física para evitar  vous blesser, installez une gr
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal  en verre n’est pas en place, est craqué ou brisé. Confiez le  removed, cracked or broken. Replacement of the glass  remplacement du panneau à un technicien agréé  should be done by 
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS HOMEOWNER’S INSTRUCTIONS: ATTACHING “SAFETY-IN-OPERATION” WARNINGS ATTACHING “SAFETY-IN-OPERATION” APPOSITION DES MISES EN GARDE RELATIVES  COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD  WARNINGS à LA SÉCURITÉ D’UTILISATION EN OPERACIóN  Your fireplace has been furnished with safety Votre foyer a été livré avec des étiquettes de sécurité qui Su chimenea incluye etiquetas de 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Appliance Installation, Service,  Appliance Operation Notices Warranty Information and Maintenance Notices Your gas appliance is covered by a limited  Do not operate appliance with the glass  twenty-year warranty. You will find a copy  front removed, cracked, or broken. IMPORTANT: Improper installation,  of the warranty accompanying this manual.   adjustment, alteratio
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Gas Pressure Requirements Orifice Sizes  GENERAL INFORMATION (continued) (Sea Level to High Altitude – All Models) The fireplace models covered in this manual are  These appliances are tested and approved for  B-vented decorative gas appliances designed  Inlet Gas Supply Pressure  for residential application. installation at elevations of 0–4500 feet (0–1372  (all mode
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS OPERATION AND CARE OF YOUR APPLIANCE GAS CONTROLS / CONTROL  COMPARTMENT ACCESS        WARNING  Fireplace gas controls are located in the lower  control compartment under the firebox (see  Young children should be carefully supervised when they are in the  Figure 1). Remove the control compartment  same room as the appliance.  Toddlers, young children and others  door 
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        O O W W IN OUT IN T T H H N N ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS ON/OFF Control IMPORTANT: Do NOT assume your fire- Appliance Controls place has a complete supplemental com- Available ON/OFF control options for both  Operation of millivolt and electronic gas  bustion air system, and do NOT operate  MILLIVOLT and ELECTRONIC models include a  control systems differs. Before lighting and  the Outside Air C
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Clean Glass Enclosure Panel Order Replacement Logs MAINTENANCE INSTRUCTIONS (Refer to “Removing and Installaing the Glass  If the logs become damaged and need to be  (See Maintenance Schedule, Page 26) Enclosure Panel” on Page 11). replaced, use only the proper replacement logs  Refer to the maintenance schedule for maintenance  Note: Clean glass after first two weeks 
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Header Only doors certified with the appliance  REMOVING AND INSTALLING  Header Spacing shall be used. Spacing Top THE GLASS ENCLOSURE PANEL Top Standoffs Seules des portes certifiées pour cet  Standoffs appareil doivent être utilisées.        WARNING  5/8” 5/8” CAUTION: DO NOT abuse glass enclosure  Nailing Nailing • Do not attempt to substitute the  Flange Flange pan
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS 4. Place the glowing ember material 5. Install the Logs.  INSTALLING VOLCANIC  (rockwool).  STONE, GLOWING EMBERS The logs have locating notches or slots to  Note: The bag of Glowing Embers  help ensure that they are properly positioned.  (ROCKWOOL), AND LOGS  contains enough rockwool for several  The top logs that rest on lower logs, do so  applications; therefore, do
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS MLBV-35 LOG PLACEMENT INSTRUCTIONS Note:  1 Rear Log 4 Left Cross Log 5 Right Cross Log • 	Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. • 	Install volcanic stone and glowing embers BEFORE installing logs.  • 	To prevent sooting, make sure logs do not cover any burner openings. MLBV Firebox Accessories/Parts Cat. No. Model No. Description H7666 
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  35”/40” MLBV MODELS  •  CARE AND OPERATION INSTRUCTIONS MLBV-40 LOG PLACEMENT INSTRUCTIONS Note:  Rear Log 1 4 Left Cross Log Right Cross Log 5 • 	Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. • 	Install volcanic stone and glowing embers BEFORE installing logs.  • 	To prevent sooting, make sure logs do not cover any burner openings. MLBV Firebox Accessories/Parts Cat. No. Model No. Description H7667 — ML
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS BURNER AIR SHUTTER   ADjUSTMENTS  (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appearance is a flame which is  blue at the base and becomes yellowish-orange  in the body of the flame.  When the appliance  is first lit, the entire flame may be blue and will  gradually turn yellowish-orange during the first  15 minutes of operation. After 15 min
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS Burner Air Shutter Adjustment  3. Allow the burner to operate for at least 15  APPLIANCE CHECKOUT minutes while observing the flame continu- Procedure ously to ensure that the proper flame ap- Millivolt Appliance Checkout pearance has been achieved (see Figures 11  The pilot flame should be steady, not lifting       WARNING and 12 on previous Page).  If the following  
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        ~ ~ ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS SPILLAGE TEST Lintel Screw Hole After appliance installation, perform this spillage  in Cabinet Top test to verify proper venting conditions: 1 - Place unit in its normally-operated condi- tion, that is, with the glass enclosure panel  in place.  Right Side 2 - Close all doors and windows in the room.  Scoop Turn on all exhaust fans in the house. 3 - Light the appl
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        I O O L I P T O it TH TPTH   TP L I P F L F O ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS UNIT CATALOG NUMBERS AND  ORDERING REPLACEMENT PRODUCT REFERENCE   SHIPPING WEIGHTS PARTS INFORMATION  A complete parts list is found at the end of We recommend that you record the important   Cat. Shipping Shipping Model this manual. Use only parts supplied from the reference information about your fireplace in  No. Weight
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        VENT TH TH TP TP ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS ELECTRONIC IGNITION WIRING DIAGRAM Pilot Burner Assembly J-Box Wiring IGNITER MODULE NOTES: 3V 1. If any of the original wire as supplied  BK     must be replaced, use Type AWM BLACK (IGNITER) W     105°C - 18 gage wire ONLY. G 2. 120 VAC, 60 Hz - Less than 3 Amps.  BLACK (SENSOR)     CAUTION: label all wires prior to  Junction Box     disconnection wh
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        ®  LENNOX HEARTH PRODUCTS  •  MERIT SERIES B-VENT GAS FIREPLACES  •  MODELS MLBV-35, MLBV-40  •  CARE AND OPERATION INSTRUCTIONS ACCESSORY COMPONENTS (continued) Style View Screen Doors These decorative but functional twin-pane screen doors provide a barrier to prevent direct contact with the hot glass surface of the fireplace front  enclosure panel. Style View Screen Doors easily install over the standard glass enclosure panel with heavy-duty magnet door latches (no hardware  required). Arch Pa