Streszczenie treści zawartej na stronie nr. 1 
                    
                        INSTALLATION AND OPERATION MANUAL
TM
Catalytic Vent-Free 
Wall-Mounted Gas Fireplace
Models: Radium-NG and Radium-LP
P/N 850,054M  REV. E, 11/2008
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
A Spanish manual is available upon request. Order P/N 850,054LS. 
Este manual está disponible en espanol por solicitud. Pida P/N 
850,054LS para la versión en espanol.
In the Commonwealth of Massachusetts:
Portland
  • Installation must be performed by 
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        •  Children and adults should be alerted to the hazard of high  1.0 IMPORTANT SAFETY AND WARNING  surface temperature and should stay away to avoid burns or  clothing ignition. INFORMATION •  Young children should be carefully supervised when they are  in the same room with the heater.      WARNINGS •  Do not place clothing or other flammable material on or near  the heater. If the information in this manual is not fol- •  Any safety screen or guard removed for servicing the heater  lowed exactl
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        These heaters are fitted with a specially designed pilot utilizing an  CONGRATULATIONS ON THE PURCHASE OF YOUR NEW  oxygen depletion sensor (ODS) which responds to the amount of  GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH  oxygen available in the room and shuts the heater off before the  PRODUCTS. oxygen level drops below 18%. It must not be adjusted or put out  of operation. If replaced then manufacturers original parts must be  When you purchased your new gas fireplace, you joined the ranks o
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        Massachusetts Requirements 5.0 UNPACKING THE APPLIANCE These fireplaces are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: Remove the straps and the top lid of the outer packaging, remove any  instructions or fixing kits. Read ALL these instructions before continuing  •  Unvented Room Heaters shall be installed in accordance with 527  to unpack or install this appliance. CMR 30.00 and 248 CMR 3.00 through 7.00: Lift off the remainin
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Example: 8.0 COMBUSTION AND VENTILATION AIR  Vent-free heater #1               9,000   BTU/Hr  Vent-free heater #2              23,000   BTU/Hr  Gas appliance #1                 35,000  BTU/Hr This heater shall not be installed in a confined space or unusually tight   (water heater) construction unless provisions are provided for adequate combustion and    Total =      67,000  BTU/Hr ventilation air. The heater may be located in unusually tight construction  provided the space is unconfined, or 
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        The minimum clearance to the ceiling above the appliance is 32” measured  9.0 SITE REQUIREMENTS from the top of the appliance glass panel. Combustible materials should not be positioned directly in front of the  This appliance is designed to be wall-hung. Do not recess any part of  appliance within a distance of 40”. the appliance into the wall. Under no circumstances should any electrical equipment e.g. plasma  This appliance may be installed in any room in a home except bathrooms  screen TV se
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        (RS) Revise "fiber wall plug" to read "wall plug" . The correct sized hole that  the installer will need to drill (if he is going to use the plugs) is diameter  8mm to a depth of 42mm. (done 1-29-08) Non-concealed gas connections may be made using the entry points To ensure customer safety, be sure to design the installation so that the  at either end of the firebox or the one in the bottom of the firebox. A strength of both the wall and any wall fixings used are sufficient. Lennox  concealed ga
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        11.0 MOUNTING THE APPLIANCE - continued       IMPORTANT  Hold heater regulator with a wrench to prevent move- Insert the wall mounting screws into the top wall plugs, taking  ment when connecting to inlet piping. care to leave the screws protruding approximately 3/8” from the  wall. Now hang the appliance onto these screws through the two  keyhole shaped holes in the back panel of the appliance.  A qualified gas appliance installer must connect the gas room  heater to the gas supply. Consult all
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        replace the burner assembly (see Page 15 for ordering information).  The valve is found on the center of the appliance behind the valve  14.0 CHECKING THE GAS CONNECTIONS cover. Remove the cover plate by unscrewing the four retaining screws.  Release the test point screws and ensure operating pressures are as  specified in Table 1 on Page 3 of these instructions. The pressure        WARNING should be checked with the gas heater burning and the control set to  high flame. Never use an open flame 
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        16.0 SPARK GAP Damper The gap between the spark electrode and the pilot should be 1/8” to  3/16” to produce a good spark.  There should be no need to adjust this  (DO NOT ATTEMPT TO ADJUST THE GAP). If under any circumstances  the piezo electric spark fails, the pilot cannot be lit manually. Adjustment to the  1/8" to 3/16" Spark Gap pilot is Not allowed Figure 7b Figure 6 - Proper Spark Gap Fixing hole 17.0 FITTING THE GLASS FACIA The glass panel is supported by two self-locking M6 screws, one 
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        First, remove the front glass facia as described in Section 17.0 only in  19.0 SERVICING reverse, remove the valve cover (4 screws) and disconnect the gas con- nection inside appliance. The gas connections to the gas valve can now  be released. Undo the four screws retaining the burner brackets to the         WARNING base and rear of the firebox. The burner may now be removed. Turn off the appliance and allow to cool before cleaning. Remove the pilot and main burner pipes and blow through to dis
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        Turn on the fireplace as per the operating instructions, and run at maximum  .0 CATALYSTS setting for 15 minutes. Position gas sample probe directly over a catalyst  via the outlet grill, on top of the appliance. Record the carbon dioxide  (CO ) concentration and then the carbon monoxide (CO) concentration        WARNING  as displayed by the analyzer - also  noting the units in which the values  are expressed. Most analyzers display carbon dioxide (CO ) concentra- Do not block the catalysts 
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        5.0 LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  • Immediately call your gas supplier from a neighbor’s phone.    A.  T his appliance has a pilot which must be lit with a piezo spark                     Follow the gas supplier’s instructions. igniter. When lighting the pilot, follow these instructions exactly.  
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        6.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged.  Purge supply or wait longer.   • Spark grounding to metal work, reset gap correctly.   • Blocked pilot, clean out internally. Pilot lights but then goes out • Severe restriction in gas supply: clear obstruction.    • Faulty thermocouple, replace pilot assembly.   • Blocked pilot, clean out.  • Blocked lint gauze, clean.  • Hold c
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        FocalPointFires Single   24/04/08 DO 005850/0 Lennox L30 Radium fitting template Artwork Size: W900 x H690 POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED 7.0 REPLACEMENT P  ARTS - RADIUM™ 16” (406mm) 13-3/4”  (350mm) FIXING POINTS:  WHEN MOUNTING PLATE IS NOT USED PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4 PUNTOS DE SUJECION: SI NO SE UTILIZA LA PLACA DE MONTAJE PERFORE L
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        8.0 POSITIONING OF FIELD REMOVABLE PARTS Glass Door Removal: Remove Removal and refitting of glass door        WARNING  the four (4) screws indicated,  assembly and burner assembly. then lift door off. Failure to position the parts in  accordance with these diagrams  or failure to use only parts specifi- cally approved with this heater  may result in  property damage  or personal injury. Visual check for cor- rect pilot flame. As our policy is  one of continuous  improvement and  development, w
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        9.0 SPECIFICATIONS Product Reference Information Cat. No. Model Ship. Wt. Ship. Volume H6064 Radium-NG 75 lb. 1 .9 cu. ft. H6070 Radium-LP 75 lb. 1 .9 cu. ft. Top View 7-3/16” 35-7/16” OPEN CLOSED 20-7/8” 3-1/8” 27-3/16” 11-1/4” 19-7/16” 23” Front View Side View 13-3/4” CTRS 18” CTRS Back View NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 17                                                                                                                                                        
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        30.0 PRODUCT REFERENCE INFORMATION WARRANTY Normally, all parts should be ordered through your Lennox distributor or  dealer. Parts will be shipped at prevailing prices at time of order. Your gas appliance is covered by a limited warranty.  Please read the  warranty to be familiar with its coverage. When ordering repair parts, always give the following information: Retain this manual. File it with your other documents for future refer- 1. The model number of the appliance. ence. .  The serial n