Streszczenie treści zawartej na stronie nr. 1 
                    
                        C
N
E
R
G
T
I
INSTALLER / CONSUMER 
SAFETY INFORMATION
PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE.
Radiance
WARNING!
IF THE INFORMATION IN THIS 
Direct Vent/Natural Vent 
MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE OR EXPLOSION 
Gas Heater
MAY RESULT CAUSING 
PROPERTY DAMAGE, PERSONAL 
Model RDVOD: 3225 thru 3232, 
INJURY OR LOSS OF LIFE.
3350 thru 3354, 3360 thru 3369, 
FOR YOUR SAFETY
3390 thru 3399 
Installation and service must be 
performed by a qualified installer, 
service
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Table Of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT:  Read all instructions and warnings carefully before starting installation.  Failure to follow these  instructions may result in a possible fire hazard and will void the warranty.  Installation & General Information  .......................................................
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Installation & Operating Instructions The Radiance Direct Vent/Natural Vent Room Heater, Model  This appliance may be installed in an aftermarket* manu- Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a factured (mobile) home, where not prohibited by state or local  vented gas appliance listed to the ANSI standard Z21.88b-2002  codes.  and CSA-2.33b-2002 for Vented Room Heaters, and  CSA 2.17- WARNING: Operation of this heater when not con
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Radiance Direct Vent/Natural Vent Stove Dimensions See Page 6 for Flue Collar  14 ���" 7" Outer Dia. Centerline Dimensions. (3.7cm) (1.8cm) 4 ���" (1.2cm) � ����������� � 29���" (7.6cm) � � � � � � � � 28" (711mm) Supply Inlet 5" (127mm) 9���" 31" (241mm) (7.9cm) 18���" 4188 (464mm) Fig. 1  Radiance dimensions. ST126 RDV40 dimensions Attention 10/99 The Radiance stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be convert
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in  the absence of local codes, with the National Fuel Gas  Direct Vent System Only Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP- TION:  Do not derate this appliance for altitude.  Main- tain the manifold pressure at 3.5” w.c. for Natural Gas,  and 10” w.c. for Propane). A D In Canada, installation must be in accordance with the  B current CSA B-149.1 Installation Code
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Parallel Installation: Minimum Clearance  Wall Centerline from Floor and Flue Centerline, Direct Vent and Natu- Direct Vent Only ral Vent 42" (1070mm) Min. Alcove Width 4" (102mm) 48" (1220mm) Max. Alcove  Depth A 6" 6" ST130 (150mm) (150mm) Fig. 3  Parallel installation, minimum back and side clear- ances, and flue centerlines. ST131b �����  A ���� � ������� Effective Minimum Corner Installation: Minimum Clearance and  ����� Centerline 57” (1448 mm) 
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Horizontal Termination -  Gas Specifications Direct Vent ONLY     Max. Min. The vent must rise vertically a minimum of 24” (610mm)      Input Input off the top of the unit, before the first elbow. The hori-  Model Fuel Gas Control BTU/h BTU/h zontal run may extend up to 20’ (6m) and include a   RDVODRN Nat Millivolt 35,000 25,000 vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termi-  RDVODRP Prop Millivolt 35,000 27,500 nation must also meet the
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Vertical Termination - Direct Vent ONLY Vent Termination Clearances A vertical vent system must terminate no less than 8’  When planning the installation, consider the location  (2.44m) and no more than 40’ (12m) above the appli- of the vent terminal and clearances. Some of the most  ance flue collar. A 2 ¹⁄₄" restrictor plate (supplied) must  common clearances to keep in mind are shown in Figure 9.  be used, where specified, in all vertically terminat
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Vent Termination Clearances Your stove is approved to be vented either through the  There must not be any obstruction such as bushes,  side wall, or vertical through the roof. garden sheds, fences, decks or utility buildings within  24” from the front of the termination hood. • CFM Corporation does not require any opening  for inspection of vent pipe. Do not locate termination hood where excessive snow  or ice build up may occur. Be sure to check ven
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        V Operable Radiance Direct Vent/Natural Vent Gas Heater  General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B J X B I X V K A CFM145a AREA WHERE TERMINAL IS NOT PERMITTED V VENT TERMINATION X AIR SUPPLY INLET 1 2   Canadian Installations US Installations CFM145a DV Termin Location  A = Clearance above grade, veranda, porch,  12” (30cm)  12” (30cm) 5/01/01 Rev. 12/05/01    deck, or balcony sta  B = C
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.  Inside Corner Alcove Applications* Outside Corner D C C F = Combustible  G =   6" (152 mm) Combustible   V G   6" (152 mm) Noncombustible  V E   2" (51 mm) Noncombustible  O V F   2" (51 mm) Balcony - Balcony -  with no side wall with perpendicular side wall E = Min. 6” (152 mm) for  non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O =
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Min. Through the Wall Vent Kit 7TFSSK Venting Requirements and Options -  (1) 90-Degree Elbow (CG) Direct Vent ONLY (1) 24” Straight pipe (CG) (1) 24” - 42” Adjustable Straight Pipe Approved Vent System Components (1) Side Wall Termination The Stardance Heater must be vented to the outdoors  (1) Firestop through an adjacent exterior wall or through the roof. The  (1) Zero-clearance sleeve venting system must be comprised of the appropriate  (1) Hardw
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Assembly Procedures   WARNING Failure to position the parts in accor- dance with these diagrams or failure to  use only parts specifically approved for  use with this heater may result in property dam- age or personal injury. This heater and components are heavy. Have  help available for assembly. Tools Required •  Phillips screwdriver (stub) •  power drill •  utility knife   •  reciprocating saw ST720 •  metal drill bit:  size 28 (.140”/3.5mm)  Fig. 
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  WARNING This appliance is equipped with a three-prong  (grounded) plug for your protection against shock  hazard and should be plugged directly into a  properly grounded three-prong receptacle. Do not  cut or remove the grounding prong from this plug. Install the Optional Fan If  you are installing the optional convection Fan Kit  #2767 (FK26), continue here. It is easiest to install fan  kit before connecting gas line. If you are not installing a  F
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater 4. Attach the Inner Vent Assembly to the stove. Venting System Assembly - Direct Vent •  Run a bead of sealant around the bottom end of  General Information the starter pipe and attach the assembly to the stove  The Radiance is approved for installation only with the  using three 1/4-20 x 3/8” Phillips screws provided in  vent components listed on Page 11. Follow the vent  the parts bag. (Fig. 20) component instructions exactly. For U.S. installation
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  ST651 ST650 Fig. 23  Simpson Dura-Vent - install outer adapter pipe.  Fig. 21   Fasten outer pipe with #12 x 1/2” sheet metal screw. Side Wall Termination Assembly Install the Vent Adapter Pipe  1. Locate the vent opening on the wall. Refer to Page  (Simpson Dura-Vent Components) 6, Figure 5, to determine the opening centerline.  It may be necessary to first position the stove and  1. Install the Restrictor Plate. Consult Page 7 to de- measure to find 
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater 6. Install the elbow using 3 sheet metal screws at each  12” joint.  (305mm)  Sleeve Max. Length 7. Measure, and cut if needed, the appropriate length  of pipe section needed to make the connection  through the wall. Include a 2” overlap; i.e. from the  elbow to the outside wall face, about 2” or the dis- tance required if installing a second 90° elbow. (Fig.  #8 Sheet  27) Metal Screws 8. Slip the wall plate and trim collar over the interior  end of
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  11. For CFM only: Install Charcoal Gray Pipe Rings  (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP)  Recessed Wall at pipe joints, if desired. Firestop Seal Both Termi- nal Ends Finishing  Sheet Metal  Collar Screws and  Bracket Wall Screws  and Anchors Waterproof Seal  Around Pipe 7” Pipe Wall Plate ST219 Caulk Plate Joint with  ST217 Weatherproof Sealant Fig. 30  Use extension brackets to mount snorkel against  Fig. 29  Install the vent terminal. 
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Make certain the vent system conforms to all other  requirements for vertical termination as specified on  Use three #5  Page 9. sheet metal  screws at  This installation will require you to first determine the  each joint roof pitch and use the appropriate vent components.   Refer to Figure 9 on page 9. Sealant Storm Collar 1. Locate the final position of the stove, observing all  clearances for both the vent and the stove. 2. Plumb to the center of th
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  The Radiance stove, when installed as a Natural vent  Install Log Set heater, includes a vent safety switch. (Page 34, Figure  67) Operating the stove when it is not connected to a  Before beginning log installation, remove stove front  properly  installed and maintained venting system, or  and glass frame. Refer to Figures 36 and 37. tampering with or disconnecting the vent safety switch,  can result in carbon monoxide (CO) poisoning and  possible d