Streszczenie treści zawartej na stronie nr. 1 
                    
                        INSTALLATION INSTRUCTIONS
B-Vent Gas Fireplaces 
SLBV 35/40 Models
P/N 506009-02   Rev. B   06/2011 
This manual is one of a set of two supporting this product.  
MODELS
Refer to P/N 506010-02 for Care and Operation Instructions.
MILLIVOLT: ELECTRONIC:
Ce manuel est disponible en francais, simplement  
SLBV-35NM SLBV-40NM SLBV-35NE
en faire la demande. Numéro de la pièce 506223-19.
SLBV-35PM SLBV-40PM SLBV-40NE
ITS Report No. 100017854
INSTALLER: Leave this manual with the appliance.
CONSUMER: R
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS TABLE Of CONTENTS  PACKAGING        WARNING  Packaging .........................................Page 2 The assembled vented gas fireplace is packaged  with the following items: Introduction ......................................Page 2 Young children should be care- fully supervised when they are  General Information ..........................Page 2 1 - One log set located in firebox area. 2 - One envelope 
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Installation must conform to local codes, or, in  GENERAL INf ORMATION    the absence of local codes, with the National  (continued) Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest  edition), or the Natural Gas and Propane Instal-        WARNING  lation Code, CAN/CSA B149.1 (latest edition).  Improper installation, adjust- The appliance, when installed, must be electri- ment, alteration, service or  cally groun
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        O W OUT IN IN T H N ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS ORIfICE SIzES GAS VALVE dIAGRAMS GAS PRESSURE REqUIREMENTS  Sea Level to High Altitude   (All Models) See Figure 1 for millivolt models and Figure 2  (All Models) for electronic models. Tables 2 and 3 show the appliances' inlet and  manifold gas pressure requirements: These appliances are tested and approved for  Pilot Adjustment installation at elevations of 0–4500 feet (0–1372 Main Ga
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Combustion air kits are optional and must be  COLd CLIMATE INSULATION LOCATION installed before removing the securing screw  allowing the movement of the combustion air  For cold climate installations, seal all cracks In selecting the location, the aesthetic and  actuator arm (see Step 5 on Page 14). functional use of the appliance are primary  around your appliance with noncombustible  material and wherev
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS VENT TERMINATION   Termination Heights for Vents  Gas Vent Rule Above flat Or Sloped Roofs CLEARANCES Ref. NfPA 54 / ANSI z223.1 Roof Pitch * f eet * Meters Multiple Terminations Flat to 6/12 1.0 0.3 These appliances may vent adjacent to and at  X the same level with any other gas appliances  6/12 to 7/12 1.25 0.38 12 (including direct vent appliances), provided  Roof Pitch is X/12 7/12 to 8/12 1.5 0.46 th
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUSTIBLES At 14" minimum side At 8-1/4" side  Appliance and Vent Clearances wall clearance, a wall clearance, a  Top View of  combustible wall can combustible wall  f ireplace project to any length. can project 12". The appliance is approved with zero clearance to combustible materials  on all sides (as detailed in Table 6), with the following exception: When  the unit is installed
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Step 5.  (Page 14) [OPTIONAL]: Install  PRE-INSTALLATION STEPS  outside supplemental combustion  Header (Remove Glass Enclosure Panel) Top  air kit. Spacing Standoff Top The appliance is shipped with all gas controls  Spacers* Standoffs Step 6. (Page 15) Make connection to gas  and components installed and pre-wired.  supply. *IMPORTANT!  Note: Remove the glass enclosure panel  5/8" Bend up the  5/8” befor
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS f IREPLACE ANd f RAMING SPECIf ICATIONS f IREPLACE f RAMING SPECIf ICATIONS  NOTE: Diagrams, illustrations and  Construct framing with 2x4 or larger lumber. photographs are not to scale. Product  designs, materials, dimensions,  specifications, colors, and prices are  subject to change or discontinuance  without notice.  Input (BTU/HR) - MV & Electronic Natural & Propane Gas B Models Input Rate (BTU/hr)   
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS VERTICAL VENTING THROUGH CEILING frame Ceiling Opening: To locate the center of the vertical run, use a plumb line from the ceiling above the appliance.  M N P Flue Outlet for  B-Vent Connection: H K 35 Models = 4 in. (102 mm) J L 40 Models = 5 in. (127 mm)  1/2 in. (13 mm) M 9-1/4 in. (235 mm) Q N Top View Front View P Flue Outlet for  B-Vent Connection: H K 35 Models = 4 in. (102 mm) J H J K L M N P Q Mo
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Note: Step 2. Route the Gas Line         WARNING  • All appliances are factory-equipped with  Route a 1/2" (13 mm) gas line to either side  a flexible gas line connector and 1/2 inch  of the appliance (left side routing is shown  shutoff valve (see Figure 17 on Page 15). Sharp Edges. in Figure 9 ). Gas lines must be routed, con- • See Massachusetts Requirements on Page  structed, and made of materials that
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS ON/OFF switch, the switch may be mounted  onto the Style View Door per instructions  provided in kit. • The gas valve is set in place and pre-wired at  Offset  Installations the factory on all models. Vertical  Installations Refer to Section B (below) for millivolt appli- ances and Section C (below) for electronic  appliances.  10 ft. *12 ft. Min. 10 ft. *12 ft. Min.  Minimum **15 ft. Min.  Minimum **15 ft
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        I O O L I P T O it VENT TH TH TP TP TPTH   TP TH L I P F L F O ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS J-BOX/RECEPTACLE WIRING  MILLIVOLT WIRING dIAGRAM J-BOX / RECEPTACLE WIRING 120V, 60Hz, 1PH 120V, 60HZ, 1PH CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION.  WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS OPERATION. VERIf Y PROPER OPERATION Af TER SERVICING. B-VENT APPLIANCES ONLY: The High Limit  Thermopile Switch must
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Failure to do so may result in extensive and  Step 5. [OPTIONAL] Install Outside  INSTALLATION ACCESSORIES costly rework. Before the operation of the vent  Combustion Air Kit system can be tested, the lever securing screw  The following accessory items are available for  must be removed. See Figure 15. An optional outside combustion air kit (model use in the installation of this appliance. FOAK-4, FOAK-4LD
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        ® SUPERIOR  B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Step 6. Connect the Gas Line  Gas Flex Line Connector All codes require a shut-off valve mounted in  3/8" NPT  x  Gas 1/2" x 3/8" Flare  the supply line. The orientation of the shut- Flare Fitting  Valve Shut-off Valve  off valve should face the front. Figure 16   illustrates two methods for connecting the gas  Note: The gas supply  supply. A sediment trap is recommended in the  line must be installed in 
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS Test All Connections for Gas Leaks Millivolt Appliance Checkout Step 7. Verify Appliance  (factory and field) Operation The pilot flame should be steady, not lifting  or floating. Flame should be blue in color with  Turn on burner then observe the individual  traces of orange at the outer edge.       WARNING tongues of flame on the burner.  Make sure  all ports are open and producing flame evenly  The top 
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS 4. Place the glowing ember material 5. Install the Logs.  Step 8. Install Volcanic Stone,  (rockwool).  Glowing Embers (Rockwool),   The logs have locating notches or slots to  Note: The bag of Glowing Embers  and Logs help ensure that they are properly positioned.  contains enough rockwool for several  The top logs that rest on lower logs, do so  NOTE: Turn OFF all electricity to the fire- applications; t
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        ® SUPERIOR  B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS SLBV-35 LOG PLACEMENT INSTRUCTIONS Note:  3 Left Rear Log Right Rear Log 4 • 	Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. • 	Install volcanic stone and glowing embers BEFORE installing logs.  • 	To prevent sooting, make sure logs do not cover any burner openings. SLBV firebox Accessories/Parts Cat. No. Model No. description H7244 — SLBV-35 Log Set Assembly 88L53 fGE Bag of Glowin
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        ® SUPERIOR  B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS SLBV-40 LOG PLACEMENT INSTRUCTIONS Note:  Ember Chunk 1 • 	Ceramic fiber logs are FRAGILE! Handle carefully to prevent breakage. 4 Left Rear Log 5 Right Rear Log • 	Install volcanic stone and glowing embers BEFORE installing logs.  • 	To prevent sooting, make sure logs do not cover any burner openings. SLBV firebox Accessories/Parts Cat. No. Model No. description H7245 — SLBV-40 Log Set Assembly 88L53 fGE
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        ® SUPERIOR B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS 3. Install the hood. Note the location of the  Step 9.  Install the Glass Enclosure  Step 10. Burner Air Shutter   three clips inside the top air channel above  Panel Adjustments  the glass enclosure panel. The clips are  (qUALIfIEd TECHNICIANS ONLY) equally spaced on the top surface of the air  channel opening.  If needed, use a screw-        WARNING  Flame Appearance and Sooting driver to open the clips